diff options
Diffstat (limited to 'lib/otp_mibs/mibs/OTP-EVA-MIB.mib')
-rw-r--r-- | lib/otp_mibs/mibs/OTP-EVA-MIB.mib | 568 |
1 files changed, 568 insertions, 0 deletions
diff --git a/lib/otp_mibs/mibs/OTP-EVA-MIB.mib b/lib/otp_mibs/mibs/OTP-EVA-MIB.mib new file mode 100644 index 0000000000..6fbb8ef073 --- /dev/null +++ b/lib/otp_mibs/mibs/OTP-EVA-MIB.mib @@ -0,0 +1,568 @@ +-- +-- %CopyrightBegin% +-- +-- Copyright Ericsson AB 2004-2009. All Rights Reserved. +-- +-- The contents of this file are subject to the Erlang Public License, +-- Version 1.1, (the "License"); you may not use this file except in +-- compliance with the License. You should have received a copy of the +-- Erlang Public License along with this software. If not, it can be +-- retrieved online at http://www.erlang.org/. +-- +-- Software distributed under the License is distributed on an "AS IS" +-- basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See +-- the License for the specific language governing rights and limitations +-- under the License. +-- +-- %CopyrightEnd% +-- + +OTP-EVA-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Counter32, Gauge32, Integer32 + FROM SNMPv2-SMI + TEXTUAL-CONVENTION, DisplayString, DateAndTime + FROM SNMPv2-TC + MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP + FROM SNMPv2-CONF + otpModules, otpApplications + FROM OTP-REG + OwnerString + FROM OTP-TC + ; + +otpEvaModule MODULE-IDENTITY + LAST-UPDATED "0305090900Z" + ORGANIZATION "Ericsson" + CONTACT-INFO + "Contact: Erlang Support see license agreement for Erlang/OTP." + DESCRIPTION + "This MIB is part of the OTP MIB. It defines MIB objects + for the eva application in OTP." + + REVISION "0305090900Z" + DESCRIPTION + "Changed CONTACT-INFO as it was outdated, made it more generic + to avoid such changes in the future." + + REVISION "9801270900Z" + DESCRIPTION + "Changed erroneous defintion of alarmCleared notification. + Changed erroneous name of this module to otpEvaModule." + REVISION "9712010900Z" + DESCRIPTION + "Converted to v2 SMI and placed in the OTP tree." + REVISION "9705020900Z" + DESCRIPTION + "The initial version of this MIB module. It is very much + inspired by the ANS-ALM-MIB and Axd301Eva-OMS mibs." + ::= { otpModules 6 } + +otpEvaMIB OBJECT IDENTIFIER ::= { otpApplications 4 } +otpEvaMIBConformance + OBJECT IDENTIFIER ::= { otpEvaMIB 1 } +otpEvaMIBObjects + OBJECT IDENTIFIER ::= { otpEvaMIB 2 } +otpEvaMIBEvents OBJECT IDENTIFIER ::= { otpEvaMIB 3 } +otpEvaMIBEventsV2 + OBJECT IDENTIFIER ::= { otpEvaMIBEvents 0 } + + +-- Datatypes + +AlarmSeverity ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The AlarmSeverity defines six severity levels, + which provide an indication of how it is perceived that the + capability of the managed object has been affected. Those + severity levels which represent service affecting conditions + ordered from most severe to least severe are critical, + major, minor and warning. The levels used are as defined + in X.733, ITU Alarm Reporting Function: + + o The Indeterminate severity level indicates that the + severity level cannot be determined. + + o The Critical severity level indicates that a service + affecting condition has occurred and an immediate + corrective action is required. Such a severity can be + reported, for example, when a managed object becomes + totally out of service and its capability must be restored. + + o The Major severity level indicates that a service + affecting condition has developed and an urgent corrective + action is required. Such a severity can be reported, for + example, when there is a severe degradation in the + capability of the managed object and its full capability + must be restored. + + o The Minor severity level indicates the existence of a + non-service affecting fault condition and that corrective + action should be taken in order to prevent a more serious + (for example, service affecting) fault. Such a severity + can be reported, for example, when the detected alarm + condition is not currently degrading the capacity of the + managed object. + + o The Warning severity level indicates the detection of a + potential or impending service affecting fault, before any + significant effects have been felt. Action should be taken + to further diagnose (if necessary) and correct the problem + in order to prevent it from becoming a more serious service + affecting fault. + + When an alarm is cleared, an alarmCleared event is generated. + This event clears the alarm with the currentAlarmFaultId + contained in the event. It is not required that the clearing + of previously reported alarms are reported. Therefore, a managing + system cannot assume that the absence of an alarmedCleared event + for a fault means that the condition that caused the generation + of previous alarms is still present. Managed object definers + shall state if, and under which conditions, the alarmedCleared + event is used. + + The clear value of AlarmSeverity is an action which is used when + a management station wants to clear an active alarm. This is not + possible on all systems, and thus an agent does not have support + write access for this value." + REFERENCE + "X.733, ITU Alarm Reporting Function" + SYNTAX INTEGER { + indeterminate (0), + critical (1), + major (2), + minor (3), + warning (4), + clear (5) -- Written, not read + } + +AlarmClass ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The AlarmClass type categorizes the alarm, and is + defined when the alarm is registered. It is as defined in + X.733, ITU Alarm Reporting Function: + + o communications. An alarm of this class is principally + associated with the procedures or processes required + to convey information from one point to another. + + o qos. An alarm of this class is principally associated + with a degradation in the quality of service. + + o processing. An alarm of this class is principally + associated with a software or processing fault. + + o equipment. An alarm of this class is principally + associated with an equipment fault. + + o environmental. An alarm of this class is principally + associated with a condition relating to an enclosure in + with equipment resides." + REFERENCE + "X.733, ITU Alarm Reporting Function" + SYNTAX INTEGER { + unknown (0), + communications (1), + qos (2), + processing (3), + equipment (4), + environmental (5) + } + + +-- Managed Objects + +event OBJECT IDENTIFIER ::= { otpEvaMIBObjects 1 } +alarm OBJECT IDENTIFIER ::= { otpEvaMIBObjects 2 } +currentAlarm OBJECT IDENTIFIER ::= { otpEvaMIBObjects 3 } + +-- The Event group +-- +-- The Event group controls the generation of notifications of +-- events from the system. + +eventTable OBJECT-TYPE + SYNTAX SEQUENCE OF EventEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of events defined by the system. This table is used + to control the sending of traps and to whom the traps are + sent." + ::= { event 1 } + +eventEntry OBJECT-TYPE + SYNTAX EventEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of parameters that describe an event to be + generated when certain conditions are met." + INDEX { eventIndex } + ::= { eventTable 1 } + +EventEntry ::= SEQUENCE { + eventIndex Integer32 (1..2147483647), + eventTrapName DisplayString, + eventTreatment INTEGER, + eventCommunity OCTET STRING (SIZE (0..127)), + eventSentTraps Counter32, + eventOwner OwnerString + } + +eventIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An index that uniquely identifies an entry in the + event table. Each such entry defines one event that + is to be generated when the appropriate conditions + occur. The value for each eventIndex must remain + constant, at least from one re-initialization of the + entity's network management system to the next + re-initialization." + ::= { eventEntry 1 } + +eventTrapName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The identifier of the corresponding trap. + NOTE: this should be an OID in SNMPv2, but must be + a string in v1." + ::= { eventEntry 2 } + +eventTreatment OBJECT-TYPE + SYNTAX INTEGER { + none(1), + log(2), + snmpTrap(3), + logAndTrap(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines how the system shall treat this event. In the + case of snmpTrap, an SNMP trap is sent to one or more + management stations. In the case of log, the event is + guaranteed to be logged in a log according to some log + strategy. Each such log strategy may define a MIB module + for control and examination of logs." + ::= { eventEntry 3 } + +eventCommunity OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..127)) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "If an SNMP trap is to be sent, it will be sent to + the SNMP community specified by this octet string." + ::= { eventEntry 4 } + +eventSentTraps OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of times this event has been sent as a trap." + ::= { eventEntry 5 } + +eventOwner OBJECT-TYPE + SYNTAX OwnerString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The manager entity that 'owns' this event entry, and is + therefore responsible for its contents." + ::= { eventEntry 6 } + +eventTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "This object may be included in a trap definition for an event. + It specifies the time the event was generated." + ::= { event 2 } + + +-- The Alarm group +-- +-- The Alarm group extends the Event group with objects for alarms. + +alarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Contains additional information for alarm events." + ::= { alarm 1 } + +alarmEntry OBJECT-TYPE + SYNTAX AlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of parameters for alarms." + INDEX { eventIndex } + ::= { alarmTable 1 } + +AlarmEntry ::= SEQUENCE { + alarmClass AlarmClass, + alarmSeverity AlarmSeverity + } + +alarmClass OBJECT-TYPE + SYNTAX AlarmClass + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The class of this alarm." + ::= { alarmEntry 1 } + +alarmSeverity OBJECT-TYPE + SYNTAX AlarmSeverity + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The perceived severity that shall apply to the + associated alarms." + ::= { alarmEntry 2 } + + +-- The CurrentAlarm group +-- +-- The CurrentAlarm group is a collection of objects for monitoring of +-- active alarms in the system. + +numberOfCurrentAlarms OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Number of currently active alarms in the system." + ::= { currentAlarm 1 } + +currentAlarmLastTimeChanged OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time an entry in the currentAlarmTable was changed. + It may be used by a management station as a value to + poll. If the value is changed, the management station + knows that the currentAlarmTable has been updated." + ::= { currentAlarm 2 } + +currentAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF CurrentAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of currently active alarms in the system." + ::= { currentAlarm 3 } + +currentAlarmEntry OBJECT-TYPE + SYNTAX CurrentAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of parameters that describe a currently active + alarm." + INDEX { currentAlarmFaultId } + ::= { currentAlarmTable 1 } + +CurrentAlarmEntry ::= SEQUENCE { + currentAlarmFaultId Integer32 (1..2147483647), + currentAlarmEventIndex Integer32 (1..2147483647), + currentAlarmObject OBJECT IDENTIFIER, + currentAlarmCause OBJECT IDENTIFIER, + currentAlarmSeverity AlarmSeverity, + currentAlarmTime DateAndTime, + currentAlarmInformation DisplayString, + currentAlarmExtra1 OBJECT IDENTIFIER, + currentAlarmExtra2 OBJECT IDENTIFIER + } + +currentAlarmFaultId OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An id that uniquely identifies a fault. Each fault is + represented as one an entry in the currentAlarmTable." + ::= { currentAlarmEntry 1 } + +currentAlarmEventIndex OBJECT-TYPE + SYNTAX Integer32 (1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A pointer into the eventTable. Points to the event + corresponding to this alarm." + ::= { currentAlarmEntry 2 } + +currentAlarmObject OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The alarming object." + ::= { currentAlarmEntry 3 } + +currentAlarmCause OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The probable cause of the alarm." + ::= { currentAlarmEntry 4 } + +currentAlarmSeverity OBJECT-TYPE + SYNTAX AlarmSeverity + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The perceived severity of the fault. A manager can set + this value to clear only. When set to clear, the alarm + is removed from this table, and a 'clearAlarm' event is + generated." + ::= { currentAlarmEntry 5 } + +currentAlarmTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time the fault was detected." + ::= { currentAlarmEntry 6 } + +currentAlarmInformation OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Additional information pin-pointing the problem." + ::= { currentAlarmEntry 7 } + +currentAlarmExtra1 OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An extra parameter used for some alarms at their own + discretion. Can be used for example to identify + additional objects in the alarm, or instead of + currentAlarmInformation to pin-point the problem, if the + additional information is defined in some MIB." + ::= { currentAlarmEntry 8 } + +currentAlarmExtra2 OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An extra parameter used for some alarms at their own + discretion. Can be used for example to identify + additional objects in the alarm, or instead of + currentAlarmInformation to pin-point the problem, if the + additional information is defined in some MIB." + ::= { currentAlarmEntry 9 } + + +-- Events + +alarmCleared NOTIFICATION-TYPE + OBJECTS { + currentAlarmEventIndex, + eventTime + } + STATUS current + DESCRIPTION + "This event is sent when an alarm has been cleared, + either by the application or by an operator. Note that the + currentAlarmFaultId is implicitly sent as the instance identifier + for currentAlarmEventIndex." + ::= { otpEvaMIBEventsV2 1 } + + +-- conformance information + +otpEvaMIBCompliances + OBJECT IDENTIFIER ::= { otpEvaMIBConformance 1 } +otpEvaMIBGroups + OBJECT IDENTIFIER ::= { otpEvaMIBConformance 2 } + + +-- compliance statements + +otpEvaBasicCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for SNMPv2 entities which + implement the OTP-EVA-MIB." + MODULE -- this module + MANDATORY-GROUPS { eventGroup, + alarmGroup, + currentAlarmGroup, + evaEventsGroup } + + ::= { otpEvaMIBCompliances 1 } + + +-- units of conformance + +eventGroup OBJECT-GROUP + OBJECTS { eventTrapName, + eventTreatment, + eventCommunity, + eventSentTraps, + eventOwner, + eventTime } + STATUS current + DESCRIPTION + "A collection of objects providing basic instrumentation + and control of the events defined in the OTP system." + ::= { otpEvaMIBGroups 1 } + +alarmGroup OBJECT-GROUP + OBJECTS { alarmClass, + alarmSeverity } + STATUS current + DESCRIPTION + "A collection of objects providing basic instrumentation + and control of the alarms defined the OTP system." + ::= { otpEvaMIBGroups 2 } + +currentAlarmGroup OBJECT-GROUP + OBJECTS { numberOfCurrentAlarms, + currentAlarmLastTimeChanged, + currentAlarmEventIndex, + currentAlarmObject, + currentAlarmCause, + currentAlarmSeverity, + currentAlarmTime, + currentAlarmInformation, + currentAlarmExtra1, + currentAlarmExtra2 } + STATUS current + DESCRIPTION + "A collection of objects providing basic instrumentation + of the activa alarm list in the OTP system." + ::= { otpEvaMIBGroups 3 } + +evaEventsGroup NOTIFICATION-GROUP + NOTIFICATIONS { alarmCleared } + STATUS current + DESCRIPTION + "The notification which is generated from EVA." + ::= { otpEvaMIBGroups 4 } + + +END |