aboutsummaryrefslogtreecommitdiffstats
path: root/lib/otp_mibs/mibs/OTP-EVA-MIB.mib
diff options
context:
space:
mode:
Diffstat (limited to 'lib/otp_mibs/mibs/OTP-EVA-MIB.mib')
-rw-r--r--lib/otp_mibs/mibs/OTP-EVA-MIB.mib568
1 files changed, 568 insertions, 0 deletions
diff --git a/lib/otp_mibs/mibs/OTP-EVA-MIB.mib b/lib/otp_mibs/mibs/OTP-EVA-MIB.mib
new file mode 100644
index 0000000000..6fbb8ef073
--- /dev/null
+++ b/lib/otp_mibs/mibs/OTP-EVA-MIB.mib
@@ -0,0 +1,568 @@
+--
+-- %CopyrightBegin%
+--
+-- Copyright Ericsson AB 2004-2009. All Rights Reserved.
+--
+-- The contents of this file are subject to the Erlang Public License,
+-- Version 1.1, (the "License"); you may not use this file except in
+-- compliance with the License. You should have received a copy of the
+-- Erlang Public License along with this software. If not, it can be
+-- retrieved online at http://www.erlang.org/.
+--
+-- Software distributed under the License is distributed on an "AS IS"
+-- basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See
+-- the License for the specific language governing rights and limitations
+-- under the License.
+--
+-- %CopyrightEnd%
+--
+
+OTP-EVA-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
+ Counter32, Gauge32, Integer32
+ FROM SNMPv2-SMI
+ TEXTUAL-CONVENTION, DisplayString, DateAndTime
+ FROM SNMPv2-TC
+ MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
+ FROM SNMPv2-CONF
+ otpModules, otpApplications
+ FROM OTP-REG
+ OwnerString
+ FROM OTP-TC
+ ;
+
+otpEvaModule MODULE-IDENTITY
+ LAST-UPDATED "0305090900Z"
+ ORGANIZATION "Ericsson"
+ CONTACT-INFO
+ "Contact: Erlang Support see license agreement for Erlang/OTP."
+ DESCRIPTION
+ "This MIB is part of the OTP MIB. It defines MIB objects
+ for the eva application in OTP."
+
+ REVISION "0305090900Z"
+ DESCRIPTION
+ "Changed CONTACT-INFO as it was outdated, made it more generic
+ to avoid such changes in the future."
+
+ REVISION "9801270900Z"
+ DESCRIPTION
+ "Changed erroneous defintion of alarmCleared notification.
+ Changed erroneous name of this module to otpEvaModule."
+ REVISION "9712010900Z"
+ DESCRIPTION
+ "Converted to v2 SMI and placed in the OTP tree."
+ REVISION "9705020900Z"
+ DESCRIPTION
+ "The initial version of this MIB module. It is very much
+ inspired by the ANS-ALM-MIB and Axd301Eva-OMS mibs."
+ ::= { otpModules 6 }
+
+otpEvaMIB OBJECT IDENTIFIER ::= { otpApplications 4 }
+otpEvaMIBConformance
+ OBJECT IDENTIFIER ::= { otpEvaMIB 1 }
+otpEvaMIBObjects
+ OBJECT IDENTIFIER ::= { otpEvaMIB 2 }
+otpEvaMIBEvents OBJECT IDENTIFIER ::= { otpEvaMIB 3 }
+otpEvaMIBEventsV2
+ OBJECT IDENTIFIER ::= { otpEvaMIBEvents 0 }
+
+
+-- Datatypes
+
+AlarmSeverity ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The AlarmSeverity defines six severity levels,
+ which provide an indication of how it is perceived that the
+ capability of the managed object has been affected. Those
+ severity levels which represent service affecting conditions
+ ordered from most severe to least severe are critical,
+ major, minor and warning. The levels used are as defined
+ in X.733, ITU Alarm Reporting Function:
+
+ o The Indeterminate severity level indicates that the
+ severity level cannot be determined.
+
+ o The Critical severity level indicates that a service
+ affecting condition has occurred and an immediate
+ corrective action is required. Such a severity can be
+ reported, for example, when a managed object becomes
+ totally out of service and its capability must be restored.
+
+ o The Major severity level indicates that a service
+ affecting condition has developed and an urgent corrective
+ action is required. Such a severity can be reported, for
+ example, when there is a severe degradation in the
+ capability of the managed object and its full capability
+ must be restored.
+
+ o The Minor severity level indicates the existence of a
+ non-service affecting fault condition and that corrective
+ action should be taken in order to prevent a more serious
+ (for example, service affecting) fault. Such a severity
+ can be reported, for example, when the detected alarm
+ condition is not currently degrading the capacity of the
+ managed object.
+
+ o The Warning severity level indicates the detection of a
+ potential or impending service affecting fault, before any
+ significant effects have been felt. Action should be taken
+ to further diagnose (if necessary) and correct the problem
+ in order to prevent it from becoming a more serious service
+ affecting fault.
+
+ When an alarm is cleared, an alarmCleared event is generated.
+ This event clears the alarm with the currentAlarmFaultId
+ contained in the event. It is not required that the clearing
+ of previously reported alarms are reported. Therefore, a managing
+ system cannot assume that the absence of an alarmedCleared event
+ for a fault means that the condition that caused the generation
+ of previous alarms is still present. Managed object definers
+ shall state if, and under which conditions, the alarmedCleared
+ event is used.
+
+ The clear value of AlarmSeverity is an action which is used when
+ a management station wants to clear an active alarm. This is not
+ possible on all systems, and thus an agent does not have support
+ write access for this value."
+ REFERENCE
+ "X.733, ITU Alarm Reporting Function"
+ SYNTAX INTEGER {
+ indeterminate (0),
+ critical (1),
+ major (2),
+ minor (3),
+ warning (4),
+ clear (5) -- Written, not read
+ }
+
+AlarmClass ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The AlarmClass type categorizes the alarm, and is
+ defined when the alarm is registered. It is as defined in
+ X.733, ITU Alarm Reporting Function:
+
+ o communications. An alarm of this class is principally
+ associated with the procedures or processes required
+ to convey information from one point to another.
+
+ o qos. An alarm of this class is principally associated
+ with a degradation in the quality of service.
+
+ o processing. An alarm of this class is principally
+ associated with a software or processing fault.
+
+ o equipment. An alarm of this class is principally
+ associated with an equipment fault.
+
+ o environmental. An alarm of this class is principally
+ associated with a condition relating to an enclosure in
+ with equipment resides."
+ REFERENCE
+ "X.733, ITU Alarm Reporting Function"
+ SYNTAX INTEGER {
+ unknown (0),
+ communications (1),
+ qos (2),
+ processing (3),
+ equipment (4),
+ environmental (5)
+ }
+
+
+-- Managed Objects
+
+event OBJECT IDENTIFIER ::= { otpEvaMIBObjects 1 }
+alarm OBJECT IDENTIFIER ::= { otpEvaMIBObjects 2 }
+currentAlarm OBJECT IDENTIFIER ::= { otpEvaMIBObjects 3 }
+
+-- The Event group
+--
+-- The Event group controls the generation of notifications of
+-- events from the system.
+
+eventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of events defined by the system. This table is used
+ to control the sending of traps and to whom the traps are
+ sent."
+ ::= { event 1 }
+
+eventEntry OBJECT-TYPE
+ SYNTAX EventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters that describe an event to be
+ generated when certain conditions are met."
+ INDEX { eventIndex }
+ ::= { eventTable 1 }
+
+EventEntry ::= SEQUENCE {
+ eventIndex Integer32 (1..2147483647),
+ eventTrapName DisplayString,
+ eventTreatment INTEGER,
+ eventCommunity OCTET STRING (SIZE (0..127)),
+ eventSentTraps Counter32,
+ eventOwner OwnerString
+ }
+
+eventIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ event table. Each such entry defines one event that
+ is to be generated when the appropriate conditions
+ occur. The value for each eventIndex must remain
+ constant, at least from one re-initialization of the
+ entity's network management system to the next
+ re-initialization."
+ ::= { eventEntry 1 }
+
+eventTrapName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The identifier of the corresponding trap.
+ NOTE: this should be an OID in SNMPv2, but must be
+ a string in v1."
+ ::= { eventEntry 2 }
+
+eventTreatment OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ log(2),
+ snmpTrap(3),
+ logAndTrap(4)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Defines how the system shall treat this event. In the
+ case of snmpTrap, an SNMP trap is sent to one or more
+ management stations. In the case of log, the event is
+ guaranteed to be logged in a log according to some log
+ strategy. Each such log strategy may define a MIB module
+ for control and examination of logs."
+ ::= { eventEntry 3 }
+
+eventCommunity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..127))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "If an SNMP trap is to be sent, it will be sent to
+ the SNMP community specified by this octet string."
+ ::= { eventEntry 4 }
+
+eventSentTraps OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times this event has been sent as a trap."
+ ::= { eventEntry 5 }
+
+eventOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The manager entity that 'owns' this event entry, and is
+ therefore responsible for its contents."
+ ::= { eventEntry 6 }
+
+eventTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS accessible-for-notify
+ STATUS current
+ DESCRIPTION
+ "This object may be included in a trap definition for an event.
+ It specifies the time the event was generated."
+ ::= { event 2 }
+
+
+-- The Alarm group
+--
+-- The Alarm group extends the Event group with objects for alarms.
+
+alarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Contains additional information for alarm events."
+ ::= { alarm 1 }
+
+alarmEntry OBJECT-TYPE
+ SYNTAX AlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters for alarms."
+ INDEX { eventIndex }
+ ::= { alarmTable 1 }
+
+AlarmEntry ::= SEQUENCE {
+ alarmClass AlarmClass,
+ alarmSeverity AlarmSeverity
+ }
+
+alarmClass OBJECT-TYPE
+ SYNTAX AlarmClass
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The class of this alarm."
+ ::= { alarmEntry 1 }
+
+alarmSeverity OBJECT-TYPE
+ SYNTAX AlarmSeverity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The perceived severity that shall apply to the
+ associated alarms."
+ ::= { alarmEntry 2 }
+
+
+-- The CurrentAlarm group
+--
+-- The CurrentAlarm group is a collection of objects for monitoring of
+-- active alarms in the system.
+
+numberOfCurrentAlarms OBJECT-TYPE
+ SYNTAX Gauge32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Number of currently active alarms in the system."
+ ::= { currentAlarm 1 }
+
+currentAlarmLastTimeChanged OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time an entry in the currentAlarmTable was changed.
+ It may be used by a management station as a value to
+ poll. If the value is changed, the management station
+ knows that the currentAlarmTable has been updated."
+ ::= { currentAlarm 2 }
+
+currentAlarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CurrentAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of currently active alarms in the system."
+ ::= { currentAlarm 3 }
+
+currentAlarmEntry OBJECT-TYPE
+ SYNTAX CurrentAlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters that describe a currently active
+ alarm."
+ INDEX { currentAlarmFaultId }
+ ::= { currentAlarmTable 1 }
+
+CurrentAlarmEntry ::= SEQUENCE {
+ currentAlarmFaultId Integer32 (1..2147483647),
+ currentAlarmEventIndex Integer32 (1..2147483647),
+ currentAlarmObject OBJECT IDENTIFIER,
+ currentAlarmCause OBJECT IDENTIFIER,
+ currentAlarmSeverity AlarmSeverity,
+ currentAlarmTime DateAndTime,
+ currentAlarmInformation DisplayString,
+ currentAlarmExtra1 OBJECT IDENTIFIER,
+ currentAlarmExtra2 OBJECT IDENTIFIER
+ }
+
+currentAlarmFaultId OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An id that uniquely identifies a fault. Each fault is
+ represented as one an entry in the currentAlarmTable."
+ ::= { currentAlarmEntry 1 }
+
+currentAlarmEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A pointer into the eventTable. Points to the event
+ corresponding to this alarm."
+ ::= { currentAlarmEntry 2 }
+
+currentAlarmObject OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The alarming object."
+ ::= { currentAlarmEntry 3 }
+
+currentAlarmCause OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The probable cause of the alarm."
+ ::= { currentAlarmEntry 4 }
+
+currentAlarmSeverity OBJECT-TYPE
+ SYNTAX AlarmSeverity
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The perceived severity of the fault. A manager can set
+ this value to clear only. When set to clear, the alarm
+ is removed from this table, and a 'clearAlarm' event is
+ generated."
+ ::= { currentAlarmEntry 5 }
+
+currentAlarmTime OBJECT-TYPE
+ SYNTAX DateAndTime
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The time the fault was detected."
+ ::= { currentAlarmEntry 6 }
+
+currentAlarmInformation OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Additional information pin-pointing the problem."
+ ::= { currentAlarmEntry 7 }
+
+currentAlarmExtra1 OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An extra parameter used for some alarms at their own
+ discretion. Can be used for example to identify
+ additional objects in the alarm, or instead of
+ currentAlarmInformation to pin-point the problem, if the
+ additional information is defined in some MIB."
+ ::= { currentAlarmEntry 8 }
+
+currentAlarmExtra2 OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An extra parameter used for some alarms at their own
+ discretion. Can be used for example to identify
+ additional objects in the alarm, or instead of
+ currentAlarmInformation to pin-point the problem, if the
+ additional information is defined in some MIB."
+ ::= { currentAlarmEntry 9 }
+
+
+-- Events
+
+alarmCleared NOTIFICATION-TYPE
+ OBJECTS {
+ currentAlarmEventIndex,
+ eventTime
+ }
+ STATUS current
+ DESCRIPTION
+ "This event is sent when an alarm has been cleared,
+ either by the application or by an operator. Note that the
+ currentAlarmFaultId is implicitly sent as the instance identifier
+ for currentAlarmEventIndex."
+ ::= { otpEvaMIBEventsV2 1 }
+
+
+-- conformance information
+
+otpEvaMIBCompliances
+ OBJECT IDENTIFIER ::= { otpEvaMIBConformance 1 }
+otpEvaMIBGroups
+ OBJECT IDENTIFIER ::= { otpEvaMIBConformance 2 }
+
+
+-- compliance statements
+
+otpEvaBasicCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The compliance statement for SNMPv2 entities which
+ implement the OTP-EVA-MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS { eventGroup,
+ alarmGroup,
+ currentAlarmGroup,
+ evaEventsGroup }
+
+ ::= { otpEvaMIBCompliances 1 }
+
+
+-- units of conformance
+
+eventGroup OBJECT-GROUP
+ OBJECTS { eventTrapName,
+ eventTreatment,
+ eventCommunity,
+ eventSentTraps,
+ eventOwner,
+ eventTime }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing basic instrumentation
+ and control of the events defined in the OTP system."
+ ::= { otpEvaMIBGroups 1 }
+
+alarmGroup OBJECT-GROUP
+ OBJECTS { alarmClass,
+ alarmSeverity }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing basic instrumentation
+ and control of the alarms defined the OTP system."
+ ::= { otpEvaMIBGroups 2 }
+
+currentAlarmGroup OBJECT-GROUP
+ OBJECTS { numberOfCurrentAlarms,
+ currentAlarmLastTimeChanged,
+ currentAlarmEventIndex,
+ currentAlarmObject,
+ currentAlarmCause,
+ currentAlarmSeverity,
+ currentAlarmTime,
+ currentAlarmInformation,
+ currentAlarmExtra1,
+ currentAlarmExtra2 }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects providing basic instrumentation
+ of the activa alarm list in the OTP system."
+ ::= { otpEvaMIBGroups 3 }
+
+evaEventsGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { alarmCleared }
+ STATUS current
+ DESCRIPTION
+ "The notification which is generated from EVA."
+ ::= { otpEvaMIBGroups 4 }
+
+
+END