Description
Håkan Mattsson
Håkan Mattsson
Håkan Mattsson
%VSN%
et_desc.xml
Overview
The two major components of the Event Tracer (ET) tool
is a graphical sequence chart viewer (et_viewer) and its
backing storage (et_collector). One Collector may be
used as backing storage for several simultaneous Viewers
where each one may display a different view of the same trace
data.
The interface between the Collector and its
Viewers is public in order to enable other types of
Viewers. However in the following text we will focus on
usage of the et_viewer.
The main start function is et_viewer:start/1. By
default it will start both an et_collector and an
et_viewer:
{ok, Viewer} = et_viewer:start([]).
{ok,<0.40.0>}]]>
A Viewer gets trace Events from its
Collector by polling it regularly for more Events to
display. Events are for example reported to the
Collector with et_collector:report_event/6:
Collector = et_viewer:get_collector_pid(Viewer).
<0.39.0>
3> et_collector:report_event(Collector, 60, my_shell, mnesia_tm, start_outer,
3> "Start outer transaction"),
3> et_collector:report_event(Collector, 40, mnesia_tm, my_shell, new_tid,
3> "New transaction id is 4711"),
3> et_collector:report_event(Collector, 20, my_shell, mnesia_locker, try_write_lock,
3> "Acquire write lock for {my_tab, key}"),
3> et_collector:report_event(Collector, 10, mnesia_locker, my_shell, granted,
3> "You got the write lock for {my_tab, key}"),
3> et_collector:report_event(Collector, 60, my_shell, do_commit,
3> "Perform transaction commit"),
3> et_collector:report_event(Collector, 40, my_shell, mnesia_locker, release_tid,
3> "Release all locks for transaction 4711"),
3> et_collector:report_event(Collector, 60, my_shell, mnesia_tm, delete_transaction,
3> "End of outer transaction"),
3> et_collector:report_event(Collector, 20, my_shell, end_outer,
3> "Transaction returned {atomic, ok}").
{ok,{table_handle,<0.39.0>,16402,trace_ts,
#Fun}}]]>
This actually is a simulation of the process Events
caused by a Mnesia transaction that writes a record in a local
table:
mnesia:write({my_tab, key, val}) end).]]>
At this stage when we have a couple of Events, it is time to
show how it looks like in the graphical interface of
et_viewer:
A simulated Mnesia transaction which writes one record
In the sequence chart, the actors (which symbolically has
performed the Event) are shown as named vertical bars. The
order of the actors may be altered by dragging (hold mouse button
1 pressed during the operation) the name tag of an actor and drop
it elsewhere:
Two actors has switched places
An Event may be an action performed by one single actor
(blue text label) or it may involve two actors and is then
depicted as an arrow directed from one actor to another (red text
label). Details of an Event can be shown by clicking (press
and release the mouse button 1) on the event label text or on the
arrow. When doing that a Contents Viewer window pops up. It
may look like this:
Details of a write lock message
Filters and dictionary
The Event Tracer (ET) uses named filters in various
contexts. An Event Trace filter is an Erlang fun that takes
some trace data as input and returns a possibly modified version
of it:
false | true | {true, NewEvent}
TraceData = Event | erlang_trace_data()
Event = #event{}
NewEvent = #event{}]]>
The interface of the filter function is the same as the the
filter functions for the good old lists:filtermap/2. If the filter
returns false it means that the trace data should silently
be dropped. true means that the trace data data already is
an Event Record and that it should be kept as it is.
true means that the TraceData already is an Event
Record and that it should be kept as it is. {true,
NewEvent} means that the original trace data should be
replaced with Event. This provides means to get rid of
unwanted Events as well as enabling alternate views of an
Event.
The first filter that the trace data is exposed for is the
Collector Filter. When a trace Event is reported with
et_collector:report/2 (or
et_collector:report_event/5,6) the first thing that
happens, is that a message is sent to the Collector process
to fetch a handle that contains some useful stuff, such as the
Collector Filter Fun and an Ets table identifier. Then the
Collector Filter Fun is applied and if it returns
true (or {true, NewEvent}), the Event will be stored
in an Ets table. As an optimization, subsequent calls to
et_collector:report-functions can use the handle directly
instead of the Collector Pid.
All filters (registered in a Collector or in a
Viewer) must be able to handle an Event record as
input. The Collector Filter (that is the filter named
all) is a little bit special, as its input also may be raw
Erlang Trace Data
The Collector manages a key/value based dictionary,
where the filters are stored. Updates of the dictionary is
propagated to all subscribing processes. When a Viewer is
started it is registered as a subscriber of dictionary
updates.
In each Viewer there is only one filter that is active
and all trace Events that the Viewer gets from the
Collector will pass thru that filter. By writing clever
filters it is possible to customize how the Events looks
like in the viewer. The following filter in
et/examples/et_demo.erl replaces the actor names
mnesia_tm and mnesia_locker and leaves everything
else in the record as it was:
If we now add the filter to the running Collector:
Fun = fun(E) -> et_demo:mgr_actors(E) end.
#Fun
5> et_collector:dict_insert(Collector, {filter, mgr_actors}, Fun).
ok]]>
you will see that the Filter menu in all viewers have
got a new entry called mgr_actors. Select it, and a new
Viewer window will pop up:
The same trace data in a different view
In order to see the nitty gritty details of an Event you
may click on the Event in order to start a Contents
Viewer for that Event. In the Contents Viewer
there also is a filter menu that enables inspection of the
Event from other views than the one selected in the
viewer. A click on the new_tid Event will cause a
Contents Viewer window to pop up, showing the Event
in the mgr_actors view:
The trace Event in the mgr_actors view
Select the all entry in the Filters menu
and a new Contents Viewer window will pop up showing the
same trace Event in the collectors view:
The same trace Event in the collectors view
Trace clients
As you have seen, it is possible to use the
et_collector:report_event/5,6 functions explicitly. By
using those functions you can write your own trace client that
reads trace data from any source stored in any format and just
feed the Collector with it. You may replace the default
Collector Filter with a filter that converts new exciting
trace data formats to Event Records or you may convert it
to an Event Record before you invoke
et_collector:report/2 and then rely on the default
Collector Filter to handle the new format.
There are also existing functions in the API that reads from
various sources and calls et_collector:report/2:
-
The trace Events that are hosted by the Collector may be
stored to file and later be loaded by selecting save
and load entries in the Viewers File menu
or via the et_collector API.
-
It is also possible to perform live tracing of a running
system by making use of the built-in trace support in the
Erlang emulator. These Erlang traces can be directed to files
or to ports. See the reference manual for
erlang:trace/4, erlang:trace_pattern/3,
dbg and ttb for more info.
There are also corresponding trace client types that can
read the Erlang trace data format from such files or ports.
The et_collector:start_trace_client/3 function makes
use of these Erlang trace clients and redirects the trace data
to the Collector.
The default Collector Filter converts the raw Erlang
trace data format into Event Records. If you want to
perform this differently you can of course write your own
Collector Filter from scratch. But it may probably save
you some efforts if you first apply the default filter in
et_selector:parse_event/2 before you apply your own
conversions of its output.
Global tracing
Setting up an Erlang tracer on a set of nodes and connecting
trace clients to the ports of these tracers is not intuitive. In
order to make this it easier the Event Tracer has a notion
of global tracing. When used, the et_collector process will
monitor Erlang nodes and when one connects, an Erlang tracer will
automatically be started on the newly connected node. A
corresponding trace client will also be started on the
Collector node in order to automatically forward the trace
Events to the Collector. Set the boolean parameter
trace_global to true for either the
et_collector or et_viewer in order to activate the
global tracing. There is no restriction on how many concurrent
(anonymous) collectors you can have, but you can only have one
global Collector as its name is registered in
global.
In order to further simplify the tracing, you can make use of
the et:trace_me/4,5 functions. These functions are intended
to be invoked from other applications when there are interesting
Events, in your application that needs to be
highlighted. The functions are extremely light weight as they do
nothing besides returning an atom. These functions are
specifically designed to be traced for. As the caller explicitly
provides the values for the Event Record fields, the
default Collector Filter is able to automatically provide a
customized Event Record without any user defined filter
functions.
In normal operation, the et:trace_me/4,5 calls are almost
for free. When tracing is needed, you can either activate tracing
on these functions explicitly. Or you can combine the usage of
trace_global with the usage of trace_pattern. When
set, the trace_pattern will automatically be activated on
all connected nodes.
One nice thing with the trace_pattern is that it
provides a very simple way of minimizing the amount of generated
trace data by allowing you to explicitly control the detail level
of the tracing. As you may have seen the et_viewer have a
slider called "Detail Level" that allows you to control the
detail level of the trace Events displayed in the
Viewer. On the other hand if you set a low detail level in
the trace_pattern, lots of the trace data will never be
generated and thus not sent over the socket to the trace client
and stored in the Collector.
Viewer window
Almost all functionality available in the et_viewer is
also available via shortcuts. Which key that has the same effect
as selecting a menu entry is shown enclosed in parentheses. For
example pressing the key r is equivalent to selecting the
menu entry Viewer->Refresh.
File menu:
-
Clear all events in the Collector - Deletes all
Events stored in the Collector and notifies all
connected Viewers about this.
-
Load events to the Collector from file - Loads the
Collector with Events from a file and notifies
all connected Viewers about this.
-
Save all events in the Collector to file - Saves all
Events stored in the Collector to file.
-
Print setup - Enables editing of printer setting,
such as paper and layout.
-
Print current page - Prints the events on the
current page. The page size is dependent of the selected paper
type.
-
Print all pages - Prints all events. The page size
is dependent of the selected paper type.
-
Close this Viewer - Closes this Viewer
window, but keeps all other Viewers windows and the
Collector process.
-
Close other Viewers, but this - Keeps this
Viewer window and its Collector process, but
closes all other Viewers windowsconnected to the same
Collector.
-
Close all Viewers and the Collector - Closes the
Collector and all Viewers connected to it.
Viewer menu:
-
First - Scrolls this viewer to the first
Event in the Collector.
-
Last - Scrolls this viewer to the last
Event in the Collector.
-
Prev - Scrolls this viewer one page
backwards.
-
Next - Scrolls this viewer one page
forward.
-
Refresh - Clears this viewer and re-read its
Events from the Collector.
-
Up - Scrolls a few Events backwards.
-
Down - Scrolls a few Events forward.
-
Display all actors. - Reset the settings for hidden
and/or highlighted actors.
Collector menu:
-
First - Scrollsall viewers to the first
Event in the Collector.
-
Last - Scrolls all viewers to the last
Event in the Collector.
-
Prev - Scrolls all viewers one page
backwards.
-
Next - Scrolls all viewers one page
forward.
-
Refresh - Clears all viewers and re-read
their Events from the Collector.
Filters and scaling menu:
-
ActiveFilter (=) - Starts a new Viewer window
with the same active filter and scale as the current one.
-
ActiveFilter (+) - Starts a new Viewer window
with the same active filter but a larger scale than the
current one.
-
ActiveFilter (-) - Starts a new Viewer window
with the same active filter but a smaller scale than the
current one.
-
all (0) - Starts a new Viewer with the
Collector Filter as active filter. It will cause all
events in the collector to be viewed.
-
AnotherFilter (2) - If more filters are inserted
into the dictionary, these will turn up here as entries in the
Filters menu. The second filter will get the shortcut
number 2, the next one number 3 etc. The names are sorted.
Slider and radio buttons:
-
Hide From=To - When true, this means that the
Viewer will hide all Events where the from-actor
equals to its to-actor. These events are sometimes called
actions.
-
Hide (excluded actors) - When true, this means that
the Viewer will hide all Events whose actors are
marked as excluded. Excluded actors are normally enclosed in
round brackets when they are displayed inthe
Viewer.
-
Detail level - This slider controls the resolution
of the Viewer. Only Events with a detail level
smaller than the selected one (default=100=max) are
displayed.
Other features:
-
Vertical scroll - Use mouse wheel and up/down arrows
to scroll little. Use page up/down and home/end buttons to
scroll more.
-
Display details of an event - Left mouse click on
the event label or the arrowand a new Contents Viewer
window will pop up, displaying the contents of an
Event.
-
Highlight actor (toggle) - Left mouse click on the
actor name tag. The actor name will be enclosed in square
brackets []. When one or more actors are highlighted,
only events related to those actors are displayed. All others
are hidden.
-
Exclude actor (toggle) - Right mouse click on the
actor name tag. The actor name will be enclosed in round
brackets (). When an actor is excluded, all events
related to this actor is hidden. If the checkbox Hide
(excluded actors) is checked, even the name tags and
corresponding vertical line of excluded actors will be
hidden.
-
Move actor - Left mouse button drag and drop on
actor name tag. Move the actor by first clicking on the actor
name, keeping the button pressed while moving the cursor to a
new location and release the button where the actor should be
moved to.
-
Display all actors - Press the 'a' button. Reset the
settings for hidden and/or highlighted actors.
Configuration
The Event Records in the Ets table are ordered by their
timestamp. Which timestamp that should be used is controlled via
the event_order parameter. Default is trace_ts which
means the time when the trace data was generated. event_ts
means the time when the trace data was parsed (transformed into an
Event Record).
Contents viewer window
File menu:
-
Close - Close this window.
-
Save - Save the contents of this window to file.
Filters menu:
-
ActiveFilter - Start a new Contents Viewer
window with the same active filter.
-
AnotherFilter (2) - If more filters are inserted
into the dictionary, these will turn up here as entries in the
Filters menu. The second filter will be number 2, the
next one number 3 etc. The names are sorted.
Hide menu:
-
Hide actor in viewer - Known actors are shown as a
named vertical bars in the Viewer window. By hiding the
actor, its vertical bar will be removed and the Viewer
will be refreshed.
Hiding the actor is only useful if the
max_actors threshold has been reached, as it then will
imply that the "hidden" actor will be displayed as if it were
"UNKNOWN". If the max_actors threshold not have
been reached, the actor will re-appear as a vertical bar in
the Viewer.
-
Show actor in viewer - This implies that the actor
will be added as a known actor in the Viewer with its
own vertical bar.
Search menu:
-
Forward from this event - Set this event to be the first
event in the viewer and change its display mode to be enter
forward search mode. The actor of this event (from, to or
both) will be added to the list of selected actors.
-
Reverse from this event - Set this event to be the
first Event in the Viewer and change its display
mode to be enter reverse search mode. The actor of this
Event (from, to or both) will be added to the list of
selected actors. Observe, that the Events will be shown
in reverse order.
-
Abort search. Display all - Switch the display mode
of the Viewer to show all Events regardless of
any ongoing searches. Abort the searches.