The following configuration parameters are defined for the Kernel
application. See app(3) for more information about
configuration parameters.
browser_cmd = string() | {M,F,A}
-
When pressing the Help button in a tool such as Debugger or
TV, the help text (an HTML file File) is by default
displayed in a Netscape browser which is required to be up and
running. This parameter can be used to change the command for
how to display the help text if another browser than Netscape
is preferred, or another platform than Unix or Windows is
used.
If set to a string Command, the command
"Command File" will be evaluated using os:cmd/1.
If set to a module-function-args tuple {M,F,A},
the call apply(M,F,[File|A]) will be evaluated.
distributed = [Distrib]
-
Specifies which applications are distributed and on which
nodes they may execute. In this parameter:
- Distrib = {App,Nodes} | {App,Time,Nodes}
- App = atom()
- Time = integer()>0
- Nodes = [node() | {node(),...,node()}]
The parameter is described in application(3), function
load/2.
dist_auto_connect = Value
-
Specifies when nodes will be automatically connected. If
this parameter is not specified, a node is always
automatically connected, e.g when a message is to be sent to
that node. Value is one of:
never
- Connections are never automatically connected, they
must be explicitly connected. See net_kernel(3).
once
- Connections will be established automatically, but only
once per node. If a node goes down, it must thereafter be
explicitly connected. See net_kernel(3).
permissions = [Perm]
-
Specifies the default permission for applications when they
are started. In this parameter:
- Perm = {ApplName,Bool}
- ApplName = atom()
- Bool = boolean()
Permissions are described in application(3), function
permit/2.
error_logger = Value
-
Value is one of:
tty
- Installs the standard event handler which prints error
reports to stdio. This is the default option.
{file, FileName}
- Installs the standard event handler which prints error
reports to the file FileName, where FileName
is a string.
false
-
No standard event handler is installed, but
the initial, primitive event handler is kept, printing
raw event messages to tty.
silent
-
Error logging is turned off.
global_groups = [GroupTuple]
-
Defines global groups, see global_group(3).
- GroupTuple = {GroupName, [Node]} | {GroupName, PublishType, [Node]}
- GroupName = atom()
- PublishType = normal | hidden
- Node = node()
inet_default_connect_options = [{Opt, Val}]
-
Specifies default options for connect sockets,
see inet(3).
inet_default_listen_options = [{Opt, Val}]
-
Specifies default options for listen (and
accept) sockets, see inet(3).
{inet_dist_use_interface, ip_address()}
-
If the host of an Erlang node has several network interfaces,
this parameter specifies which one to listen on. See
inet(3) for the type definition of ip_address().
{inet_dist_listen_min, First}
-
See below.
{inet_dist_listen_max, Last}
-
Define the First..Last port range for the listener
socket of a distributed Erlang node.
inet_parse_error_log = silent
-
If this configuration parameter is set, no
error_logger messages are generated when erroneous
lines are found and skipped in the various Inet configuration
files.
inetrc = Filename
-
The name (string) of an Inet user configuration file. See
ERTS User's Guide, Inet configuration.
net_setuptime = SetupTime
-
SetupTime must be a positive integer or floating point
number, and will be interpreted as the maximally allowed time
for each network operation during connection setup to another
Erlang node. The maximum allowed value is 120; if higher values
are given, 120 will be used. The default value if the variable
is not given, or if the value is incorrect (e.g. not a number),
is 7 seconds.
Note that this value does not limit the total connection
setup time, but rather each individual network operation during
the connection setup and handshake.
net_ticktime = TickTime
-
Specifies the net_kernel tick time. TickTime
is given in seconds. Once every TickTime/4 second, all
connected nodes are ticked (if anything else has been written
to a node) and if nothing has been received from another node
within the last four (4) tick times that node is considered
to be down. This ensures that nodes which are not responding,
for reasons such as hardware errors, are considered to be
down.
The time T, in which a node that is not responding is
detected, is calculated as: where:
MinT = TickTime - TickTime / 4
MaxT = TickTime + TickTime / 4
TickTime is by default 60 (seconds). Thus,
seconds.
Note: All communicating nodes should have the same
TickTime value specified.
Note: Normally, a terminating node is detected
immediately.
shutdown_timeout = integer() | infinity
-
Specifies the time application_controller will wait
for an application to terminate during node shutdown. If the
timer expires, application_controller will brutally
kill application_master of the hanging
application. If this parameter is undefined, it defaults
to infinity.
sync_nodes_mandatory = [NodeName]
-
Specifies which other nodes must be alive in order
for this node to start properly. If some node in the list
does not start within the specified time, this node will not
start either. If this parameter is undefined, it defaults to
[].
sync_nodes_optional = [NodeName]
-
Specifies which other nodes can be alive in order
for this node to start properly. If some node in this list
does not start within the specified time, this node starts
anyway. If this parameter is undefined, it defaults to
the empty list.
sync_nodes_timeout = integer() | infinity
-
Specifies the amount of time (in milliseconds) this node
will wait for the mandatory and optional nodes to start. If
this parameter is undefined, no node synchronization is
performed. This option also makes sure that global is
synchronized.
start_dist_ac = true | false
-
Starts the dist_ac server if the parameter is
true. This parameter should be set to true for
systems that use distributed applications.
The default value is false. If this parameter is
undefined, the server is started if the parameter
distributed is set.
start_boot_server = true | false
-
Starts the boot_server if the parameter is true
(see erl_boot_server(3)). This parameter should be
set to true in an embedded system which uses this
service.
The default value is false.
boot_server_slaves = [SlaveIP]
-
If the start_boot_server configuration parameter is
true, this parameter can be used to initialize
boot_server with a list of slave IP addresses.
SlaveIP = string() | atom | {integer(),integer(),integer(),integer()}
where .
Examples of SlaveIP in atom, string and tuple form
are:
'150.236.16.70', "150,236,16,70", {150,236,16,70}.
The default value is [].
start_disk_log = true | false
-
Starts the disk_log_server if the parameter is
true (see disk_log(3)). This parameter should be
set to true in an embedded system which uses this service.
The default value is false.
start_pg2 = true | false
-
Starts the pg2 server (see pg2(3)) if
the parameter is true. This parameter should be set to
true in an embedded system which uses this service.
The default value is false.
start_timer = true | false
-
Starts the timer_server if the parameter is
true (see timer(3)). This parameter should be
set to true in an embedded system which uses this
service.
The default value is false.
shutdown_func = {Mod, Func}
-
Where:
- Mod = atom()
- Func = atom()
Sets a function that application_controller calls
when it starts to terminate. The function is called as:
Mod:Func(Reason), where Reason is the terminate
reason for application_controller, and it must
return as soon as possible for application_controller
to terminate properly.