<?xml version="1.0" encoding="latin1" ?> <!DOCTYPE erlref SYSTEM "erlref.dtd"> <erlref> <header> <copyright> <year>1998</year><year>2009</year> <holder>Ericsson AB. All Rights Reserved.</holder> </copyright> <legalnotice> The contents of this file are subject to the Erlang Public License, Version 1.1, (the "License"); you may not use this file except in compliance with the License. You should have received a copy of the Erlang Public License along with this software. If not, it can be retrieved online at http://www.erlang.org/. Software distributed under the License is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License for the specific language governing rights and limitations under the License. </legalnotice> <title>snmp_notification_mib</title> <prepared></prepared> <responsible></responsible> <docno></docno> <approved></approved> <checked></checked> <date></date> <rev></rev> <file>snmp_notification_mib.xml</file> </header> <module>snmp_notification_mib</module> <modulesummary>Instrumentation Functions for SNMP-NOTIFICATION-MIB</modulesummary> <description> <p>The module <c>snmp_notification_mib</c> implements the instrumentation functions for the SNMP-NOTIFICATION-MIB, and functions for configuring the database. </p> <p>The configuration files are described in the SNMP User's Manual.</p> </description> <funcs> <func> <name>configure(ConfDir) -> void()</name> <fsummary>Configure the SNMP-NOTIFICATION-MIB</fsummary> <type> <v>ConfDir = string()</v> </type> <desc> <p>This function is called from the supervisor at system start-up. </p> <p>Inserts all data in the configuration files into the database and destroys all old rows with StorageType <c>volatile</c>. The rows created from the configuration file will have StorageType <c>nonVolatile</c>. </p> <p>If an error is found in the configuration file, it is reported using the function <c>config_err/2</c> of the error report module, and the function fails with reason <c>configuration_error</c>. </p> <p><c>ConfDir</c> is a string which points to the directory where the configuration files are found. </p> <p>The configuration file read is: <c>notify.conf</c>. </p> </desc> </func> <func> <name>reconfigure(ConfDir) -> void()</name> <fsummary>Configure the SNMP-NOTIFICATION-MIB</fsummary> <type> <v>ConfDir = string()</v> </type> <desc> <p>Inserts all data in the configuration files into the database and destroys all old data, including the rows with StorageType <c>nonVolatile</c>. The rows created from the configuration file will have StorageType <c>nonVolatile</c>. </p> <p>Thus, the data in the SNMP-NOTIFICATION-MIB, after this function has been called, is from the configuration files. </p> <p>If an error is found in the configuration file, it is reported using the function <c>config_err/2</c> of the error report module, and the function fails with reason <c>configuration_error</c>. </p> <p><c>ConfDir</c> is a string which points to the directory where the configuration files are found. </p> <p>The configuration file read is: <c>notify.conf</c>. <marker id="add_notify"></marker> </p> </desc> </func> <func> <name>add_notify(Name, Tag, Type) -> Ret</name> <fsummary>Added one notify definition</fsummary> <type> <v>Name = string()</v> <v>Tag = string()</v> <v>Type = trap | inform</v> <v>Ret = {ok, Key} | {error, Reason}</v> <v>Key = term()</v> <v>Reason = term()</v> </type> <desc> <p>Adds a notify definition to the agent config. Equivalent to one line in the <c>notify.conf</c> file.</p> <marker id="delete_notify"></marker> </desc> </func> <func> <name>delete_notify(Key) -> Ret</name> <fsummary>Delete one notify definition</fsummary> <type> <v>Key = term()</v> <v>Ret = ok | {error, Reason}</v> <v>Reason = term()</v> </type> <desc> <p>Delete a notify definition from the agent config.</p> </desc> </func> </funcs> </erlref>