The status of an aborted test due to test suite compilation error has changed from 'auto_skipped' to 'failed'. This affects both the textual log file, event handling and CT hook callbacks. The logging of compilation failures has also been improved, especially in the case of multiple test suites failing compilation.
Own Id: OTP-10816
The Test Server source code parser (erl2html2) failed to handle the macro tuple in the syntax tree returned by epp_dodger. This error has been corrected.
Own Id: OTP-12740
The Test Server application has been marked as obsolete and will be removed from OTP in the next major release (OTP 19.0).
Own Id: OTP-10923 Aux Id: OTP-12705
When running OTP tests using the ts interface, it is now possible to specify so called test categories per OTP application. A test category is represented by a CT test specification and defines an arbitrary subset of existing test suites, groups and cases. Examples of test categories are 'smoke' (smoke tests) and 'bench' (benchmarks). (Call ts:help() for more info). Also, functions for reading terms from the current test specification during test, ct:get_testspec_terms/0 and ct:get_testspec_terms/1, have been implemented.
Own Id: OTP-11962
If the last expression in a test case causes a timetrap timeout, the stack trace is ignored and not printed to the test case log file. This happens because the {Suite,TestCase,Line} info is not available in the stack trace in this scenario, due to tail call elimination. Common Test has been modified to handle this situation by inserting a {Suite,TestCase,last_expr} tuple in the correct place and printing the stack trace as expected.
Own Id: OTP-12697 Aux Id: seq12848
When installing test suites in a cross compilation environment, ts_install was not able to read the values of the environment variables specified in the configuration file. This has been fixed.
Own Id: OTP-11441
Printouts by means of ct:log/2/3 or ct:pal/2/3 from the hook functions on_tc_fail/2 and on_tc_skip/2 would (quite unexpectedly) end up in the "unexpected i/o" log file instead of in the test case log file. This behaviour has been changed so that now, all printouts (including stdio printouts) from these hook functions will be routed to the test case log file.
Own Id: OTP-12468
The format of the information printed on top of the test case (and configuration function) log file has been slightly modified, mainly in order to make the start configuration data easier to read and interpret.
Own Id: OTP-12518 Aux Id: seq12808
The source code to html code generator in Test Server (and Common Test) would fail to generate anchors in the html code for functions with non-expandable macros, resulting in bad html links to such functions. This correction lets the code generator ignore macros that can't be expanded (i.e. not pre-process them), so that correct anchors will always be produced.
Own Id: OTP-11766 Aux Id: seq12556
Make sure to install .hrl files when needed
Own Id: OTP-12197
Distribute
Own Id: OTP-12348
The mechanism for running code cover analysis with common_test has been improved. Earlier, if a test run consisted of multiple tests, cover would be started and stopped for each test. This would give "intermediate" cover logs available from the "Coverage log" link on the test suite result pages. To accumulate cover data over all tests, the 'export' option had to be used in the cover spec file. This was not well documented, and the functionality was quite confusing.
Using the 'nodes' option in the cover spec file would fail when the test run consisted of multiple tests, since the specified nodes would only be included in the cover analysis of the first test.
The repeated compilation and analysis of the same modules was also very time consuming.
To overcome these problems, ct will now only cover compile and analyze modules once per test run, i.e. once for each cover spec file. The log file is available via a new button on the top level index page. The old "Coverage log" links on the test suite result pages still exist, but they all point to the same log containing the accumulated result.
Own Id: OTP-11971
Application upgrade (appup) files are corrected for the following applications:
A new test utility for testing appup files is added to test_server. This is now used by most applications in OTP.
(Thanks to Tobias Schlager)
Own Id: OTP-11744
Calls to erlang:open_port/2 with 'spawn' are updated to handle space in the command path.
Own Id: OTP-10842
The way Common Test handles skipping of test cases has
been updated. In previous versions, returning
This update has meant a few changes that may affect Common Test users in various ways:
Own Id: OTP-11305 Aux Id: OTP-11524
Test Server installed an error handler (test_server_h) only to be able to write the name of the current test case to stdout whenever it received an error- or progress report. This functionality was not useful and has been removed. The built-in Common Test hook, cth_log_redirect, has instead been improved to now also tag all error- and progress reports in the log with suite-, group-, and/or test case name.
Own Id: OTP-11263 Aux Id: seq12251
A new log, the "Pre- and Post Test I/O Log", has been introduced, which makes it possible to capture error- and progress reports, as well as printouts made with ct:log/2 and ct:pal/2, before and after a test run. (Some minor improvements of the logging system have been made at the same time). Links to the new log are found on the Common Test Framework Log page. The Common Test User's Guide has been updated with information about the new log and also with a new section on how to synchronize external applications with Common Test by means of the CT Hook init and terminate functions.
Own Id: OTP-11272
Test Server: Report auto_skipped in major log.
Own Id: OTP-11297
Some unused code related to remote targets is removed, and documentation is updated.
Own Id: OTP-10607 Aux Id: kunagi-338 [249]
A bug in test_server_gl caused io requests containing invalid data (i.e. not unicode:chardata()) to hang, since no io reply was sent. This has been corrected.
Own Id: OTP-10991
Common Test would, in case of timetrap error, print a warning in the log if end_per_testcase wasn't implemented in the suite, even though it's an optional function. This printout has been removed.
Own Id: OTP-11052
The '-force_stop' flag to use with time-limited repeats of test runs can now be used with a new 'skip_rest' option which causes the rest of the test cases in the ongoing test job to be skipped when the time limit is reached. E.g. 'ct_run -spec xxx -duration 010000 -force_stop skip_rest'
Own Id: OTP-10856 Aux Id: OTP-10832
The unicode update of test_server for R16A introduced a few potential errors when logging to files. Sometimes ~tp or ~ts was used for formatting also when writing to files that were not opened with the {encoding,utf8} option. If then the argument contained unicode characters above 255, the file descriptor would crash. This has been corrected by the following modifications:
Also, ~tp has been changed back to ~p unless it is somehow likely that the argument includes strings. It is not obvious that this is the correct thing to do, but some decission had to be taken...
Own Id: OTP-10780
Using the force_stop flag/option to interrupt a test run caused a crash in Common Test. This problem has been solved.
Own Id: OTP-10832
Line numbering of erlang files that were not correctly indented could be wrong after coverting to html with erl2html2:convert/[2,3] (the source code pointed to from the test case). This has been corrected.
Also, there are now link targets for each line and not only for each 10th line, and link targets for functions now include the arity and not only the function name (e.g. func/1 has a link target "func-1").
Own Id: OTP-9710 Aux Id: seq11945, kunagi-201 [112]
Severe errors detected by
Own Id: OTP-9769 Aux Id: kunagi-202 [113]
The earlier undocumented cross cover feature for accumulating cover data over multiple tests has now been fixed and documented.
Own Id: OTP-9870 Aux Id: kunagi-206 [117]
If the test suite itself was included in code coverage analysis, then the test_server would not manage to set data_dir correctly for the test. This has been corrected.
Own Id: OTP-9956 Aux Id: kunagi-207 [118]
Any call to test_server:break/1 should cancel all active timetramps. However, in some cases Suite:end_per_testcase/2 is executed on a different process than the test case itself, and if test_server:break/1 was called from there, the timetraps were not cancelled. This has been corrected.
Own Id: OTP-10046 Aux Id: kunagi-174 [85]
When a test case failed because of a timetrap time
out, the
Own Id: OTP-10070 Aux Id: kunagi-175 [86]
In test_server, the same process would supervise the currently running test case and be group leader (and IO server) for the test case. Furthermore, when running parallel test cases, new temporary supervisor/group leader processes were spawned and the process that was group leader for sequential test cases would not be active. That would lead to several problems:
* Processes started by init_per_suite will inherit the group leader of the init_per_suite process (and that group leader would not process IO requests when parallel test cases was running). If later a parallel test case caused such a processto print using (for example) io:format/2, the calling would hang.
* Similarly, if a process was spawned from a parallel
test case, it would inherit the temporary group leader
for that parallel test case. If that spawned process
later - when the group of parallel tests have finished -
attempted to print something, its group leader would be
dead and there would be
Those problems have been solved by having group leaders separate from the processes that supervises the test cases, and keeping temporary group leader process for parallel test cases alive until no more process in the system use them as group leaders.
Also, a new
Own Id: OTP-10101 Aux Id: OTP-10125
The stability of
Own Id: OTP-10480 Aux Id: kunagi-318 [229]
Added a general framework for executing benchmarks of Erlang/OTP. Benchmarks for the Erlang VM and mnesia have been incorporated in the framework.
For details about how to add more benchmarks see $ERL_TOP/HOWTO/BENCHMARKS.md in the source distribution.
Own Id: OTP-10156
Update common test modules to handle Unicode:
test_server_h will now recognize info_reports written by ct connection handlers (according to the description in cth_conn_log) and ignore them as they will be completely handled by by ct_conn_log_h.
Earlier test_server_h would print a tag (testcase name) before forwarding the report to error_logger_tty_h. This would cause lots of tags in the log with no info report following (since error_logger_tty_h did not handle them).
Own Id: OTP-10571
Restore Config data if lost when test case fails.
Own Id: OTP-10070 Aux Id: kunagi-175 [86]
IO server error in test_server.
Own Id: OTP-10125 Aux Id: OTP-10101, kunagi-177 [88]
The documentation has been updated with the latest changes for the test_server_ctrl:report/2 function.
Own Id: OTP-10086 Aux Id: seq12066
The ct:get_status/0 function failed to report status if a parallel test case group was running at the time of the call. This has been fixed and the return value for the function has been updated. Please see the ct reference manual for details.
Own Id: OTP-10172
It is now possible to sort the HTML tables by clicking on the header elements. In order to reset a sorted table, the browser window should simply be refreshed. This feature requires that the browser supports javascript, and has javascript execution enabled. If the 'ct_run -basic_html' flag is used, no javascript code is included in the generated HTML code.
Own Id: OTP-9896 Aux Id: seq12034, OTP-9835
Verbosity levels for log printouts has been added. This makes it possible to specify preferred verbosity for different categories of log printouts, as well as general printouts (such as standard IO), to allow control over which strings get printed and which get ignored. New versions of the Common Test logging functions, ct:log, ct:pal and ct:print, have been introduced, with a new Importance argument added. The Importance value is compared to the verbosity level at runtime. More information can be found in the chapter about Logging in the Common Test User's Guide.
Own Id: OTP-10067 Aux Id: seq12050
The Erlang/OTP test runner ts has been extended to allow cross compilation of test suites. To cross compile the test suites first follow the normal cross compilation procedures and release the tests on the build host. Then install ts using an xcomp specification file and compile test suites using ts:compile_testcases/0. For more details see $ERL_TOP/xcomp/README.md.
Own Id: OTP-10074
After a test case timeout or abortion, the end_per_testcase function executes on a new dedicated process. The group leader for this process should be set to the IO server for the test case, which was not done properly. The result of this error was that no warnings about end_per_testcase failing or timing out were ever printed in the test case log. Also, help functions such as e.g. test_server:stop_node/1, attempting to synchronize with the IO server, would hang. The fault has been corrected.
Own Id: OTP-9666
A deadlock situation could occur if Common Test is forwarding error_handler printouts to Test Server at the same time a new test case is starting. This error has been fixed.
Own Id: OTP-9894
When a test case was killed because of a timetrap timeout, the current location (suite, case and line) was not printed correctly in the log files. This has been corrected.
Own Id: OTP-9930 Aux Id: seq12002
Test Server and Common Test would add new error handlers with each test run and fail to remove previously added ones. In the case of Test Server, this would only happen if SASL was not running on the test node. This has been fixed.
Own Id: OTP-9941 Aux Id: seq12009
If a test case process was terminated due to an exit signal from a linked process, Test Server failed to report the correct name of the suite and case to the framework. This has been corrected.
Own Id: OTP-9958 Aux Id: OTP-9855
A new optional feature has been introduced that enables Common Test to generate priv_dir directory names that are unique for each test case or config function. The name of the option/flag is 'create_priv_dir' and it can be set to value 'auto_per_run' (which is the default, existing, behaviour), or 'auto_per_tc' or 'manual_per_tc'. If 'auto_per_tc' is used, Test Server creates a dedicated priv_dir automatically for each test case (which can be very expensive in case of many and/or repeated cases). If 'manual_per_tc' is used, the user needs to create the priv_dir explicitly by calling the new function ct:make_priv_dir/0.
Own Id: OTP-9659 Aux Id: seq11930
A column for test case group name has been added to the suite overview HTML log file.
Own Id: OTP-9730 Aux Id: seq11952
It is now possible to use the post_end_per_testcase CT hook function to print a comment for a test case in the overview log file, even if the test case gets killed by a timetrap or unknown exit signal, or if the end_per_testcase function times out.
Own Id: OTP-9855 Aux Id: seq11979
Common Test will now print error information (with a time stamp) in the test case log file immediately when a test case fails. This makes it easier to see when, in time, the fault actually occured, and aid the job of locating relevant trace and debug printouts in the log.
Own Id: OTP-9904 Aux Id: seq11985, OTP-9900
Test Server has been modified to check the SASL errlog_type parameter when receiving an error logger event, so that it doesn't print reports of type that the user has disabled.
Own Id: OTP-9955 Aux Id: seq12013
If an application cannot be found by ts it is automatically skipped when testing.
Own Id: OTP-9971
By specifying a user defined function ({M,F,A} or fun) as timetrap value, either by means of an info function or by calling ct:timetrap/1, it is now possible to set a timetrap that will be triggered when the user function returns.
Own Id: OTP-9988 Aux Id: OTP-9501, seq11894
If the optional configuration functions init_per_suite/1 and end_per_suite/1 are not implemented in the test suite, local Common Test versions of these functions are called instead, and will be displayed in the overview log file. Any printouts made by the pre- or post_init_per_suite and pre- or post_end_per_suite hook functions are saved in the log files for these functions.
Own Id: OTP-9992
The test case group info function has been implemented in
Common Test. Before execution of a test case group, a
call is now made to
Own Id: OTP-9235
The look of the HTML log files generated by Common Test and Test Server has been improved (and made easier to customize) by means of a CSS file.
Own Id: OTP-9706
Fix problems in CT/TS due to line numbers in exceptions.
Own Id: OTP-9203
An error in how comments are colored in the test suite overview html log file has been corrected. As result, a new framework callback function, format_comment/1, has been introduced.
Own Id: OTP-9237
Test Server did not release SASL TTY handlers (sasl_report_tty_h and error_logger_tty_h) properly after each test run. This error has been fixed.
Own Id: OTP-9311
Automatically generated init- and end-configuration functions for test case groups caused incorrect execution order of test cases. This has been corrected.
Own Id: OTP-9369
If ct:log/2 was called with bad arguments, this could cause the Common Test IO handling process to crash. This fault has been corrected.
Own Id: OTP-9371 Aux Id: OTP-8933
A bug has been fixed that made Test Server call the end_tc/3 framework function with an incorrect module name as first argument.
Own Id: OTP-9379 Aux Id: seq11863
If end_per_testcase caused a timetrap timeout, the actual test case status was discarded and the test case logged as successful (even if the case had actually failed before the call to end_per_testcase). This fault has been fixed.
Own Id: OTP-9397
If a timetrap timeout occured during execution of of a function in a lib module (i.e. a function called directly or indirectly from a test case), the Suite argument in the end_tc/3 framework callback function would not correctly contain the name of the test suite, but the lib module. (This would only happen if the lib module was compiled with ct.hrl included). This error has been solved.
Own Id: OTP-9398
Add a proplist() type
Recently I was adding specs to an API and found that there is no canonical proplist() type defined. (Thanks to Ryan Zezeski)
Own Id: OTP-9499
XML files have been corrected.
Own Id: OTP-9550 Aux Id: OTP-9541
If a test suite would start with a test case group defined without the init_per_group/2 and end_per_group/2 function, init_per_suite/1 would not execute initially and logging of the test run would fail. This error has been fixed.
Own Id: OTP-9584
A new option, 'logopts', has been introduced, to make it possible to modify some aspects of the logging behaviour in Common Test (or Test Server). For example, whenever an io printout is made, test_server adds newline (\n) to the end of the output string. This may not always be a preferred action and can therefore be disabled by means of "ct_run ... -logopts no_nl" (or ct:run_test([..., {logopts,[no_nl]}])). A new framework callback function, get_logopts/0, has been introduced (see the ct_framework module for details).
Own Id: OTP-9372 Aux Id: OTP-9396
A new option, 'logopts', has been introduced, to make it possible to modify some aspects of the logging behaviour in Common Test (or Test Server). For example, if the html version of the test suite source code should not be generated during the test run (and consequently be unavailable in the log file system), the feature may be disabled by means of "ct_run ... -logopts no_src" (or ct:run_test([..., {logopts,[no_src]}])). A new framework callback function, get_logopts/0, has been introduced (see the ct_framework module for details).
Own Id: OTP-9396 Aux Id: seq11869, OTP-9372
It is now possible to use a tuple {M,F,A}, or a fun, as timetrap specification in the suite info function or test case info functions. The function must return a valid timeout value, as documented in the common_test man page and in the User's Guide.
Own Id: OTP-9501 Aux Id: seq11894
It was previously not possible to use timetrap value 'infinity' with ct:timetrap/1. This has been fixed.
Own Id: OTP-9159
A bug that made it impossible to cancel the previous timetrap when calling ct:timetrap/1 has been corrected.
Own Id: OTP-9233 Aux Id: OTP-9159
When running tests with auto-compilation disabled, Common Test could only display the test suite source code on html format in the test case log if the source file was located in the same directory as the pre-compiled suite. This has been modified so that Common Test now tries to locate the source file by means of the test suite module info (Suite:module_info/1). As a result, a suite may now be compiled to a different output directory (e.g. $MYTEST/bin) than the source code directory (e.g. $MYTEST/src), without the source-code-to-html generation being affected.
Own Id: OTP-9138
It is now possible to return a tuple {fail,Reason} from init_per_testcase/2. The result is that the associated test case gets logged as failed without ever executing.
Own Id: OTP-9160 Aux Id: seq11502
Added DragonflyBSD check in test_server configure.
Own Id: OTP-9249
Updated the ts*.config files to contain information relevant to testing Erlang/OTP in an open source environment.
Own Id: OTP-9017
Alpha release of Common Test Hooks (CTH). CTHs allow the users of common test to abtract out common behaviours from test suites in a much more elegant and flexible way than was possible before. Note that the addition of this feature may introduce minor changes in the undocumented behaviour of the interface inbetween common_test and test_server.
*** POTENTIAL INCOMPATIBILITY ***
Own Id: OTP-8851
Miscellaneous updates
Own Id: OTP-8976
Returning {return_group_result,failed} from end_per_group in a group that is part of a sequence, did not cause the proceeding cases (or groups) to get skipped. This has been fixed.
Own Id: OTP-8753 Aux Id: seq11644
Common Test has been updated to handle start options and test specification terms for test case groups (and test cases in groups). Also, an option named 'label', has been added that associates the test run with a name that Common Test prints in the overview HTML logs.
Own Id: OTP-8725 Aux Id: OTP-8727
It is now possible to skip all tests in a suite, or a group, by returning {fail,Reason} from the end_tc/5 framework function for init_per_suite, or init_per_group.
Own Id: OTP-8805 Aux Id: seq11664
Returning {fail,Reason} from the framework end_tc function was not handled properly by Test Server for all test suite functions.
Own Id: OTP-8492 Aux Id: seq11502
If the framework end_tc function would hang and get aborted by Test Server, there was no indication of failure in the logs. This has been fixed.
Own Id: OTP-8682 Aux Id: seq11504
It is now possible for the Test Server framework end_tc function to change the status of the test case from ok or auto-skipped to failed by returning {fail,Reason}.
Own Id: OTP-8495 Aux Id: seq11502
Test Server will now call the end_per_testcase/2 function even if the test case has been terminated explicitly (with abort_current_testcase/1), or after a timetrap timeout. Under these circumstances the return value of end_per_testcase is completely ignored. Therefore the function will not be able to change the reason for test case termination by returning {fail,Reason}, nor will it be able to save data with {save_config,Data}.
Own Id: OTP-8500 Aux Id: seq11521
Previously, a repeat property of a test case group specified the number of times the group should be repeated after the main test run. I.e. {repeat,N} would case the group to execute 1+N times. To be consistent with the behaviour of the run_test repeat option, this has been changed. N now specifies the absolute number of executions instead.
Own Id: OTP-8689 Aux Id: seq11502
The Test Server parse transform did not handle bit string comprehensions. This has been fixed.
Own Id: OTP-8458 Aux Id: OTP-8311
The tc_status value in the Config list for a test case that has failed because of a timetrap timeout, has changed from {tc_status,timeout} to {tc_status,timetrap_timeout}.
Own Id: OTP-8302
The documentation is now possible to build in an open source environment after a number of bugs are fixed and some features are added in the documentation build process.
- The arity calculation is updated.
- The module prefix used in the function names for bif's are removed in the generated links so the links will look like "http://www.erlang.org/doc/man/erlang.html#append_element-2" instead of "http://www.erlang.org/doc/man/erlang.html#erlang:append_element-2".
- Enhanced the menu positioning in the html documentation when a new page is loaded.
- A number of corrections in the generation of man pages (thanks to Sergei Golovan)
- The legal notice is taken from the xml book file so OTP's build process can be used for non OTP applications.
Own Id: OTP-8343
If the init_per_testcase/2 function fails, the test case now gets marked and counted as auto skipped, not user skipped (which would previously happen).
Own Id: OTP-8289
The documentation is now built with open source tools (xsltproc and fop) that exists on most platforms. One visible change is that the frames are removed.
Own Id: OTP-8201
It is now possible to fail a test case from the end_per_testcase/2 function, by returning {fail,Reason}.
Own Id: OTP-8284
It is now possible to fail a test case by having the end_tc/3 framework function return {fail,Reason} for the test case.
Own Id: OTP-8285
The test_server framework API (e.g. the end_tc/3 function) has been modified. See the test_server_ctrl documentation for details.
Own Id: OTP-8286 Aux Id: OTP-8285, OTP-8287
When running a suite starting with a test case group, Test Server crashed if init_per_suite/1 exited or returned skip. This has been fixed.
Own Id: OTP-8105 Aux Id: OTP-8089
Various updates and fixes in Common Test and Test Server.
Own Id: OTP-8045 Aux Id: OTP-8089,OTP-8105,OTP-8163
Errors in coverage data collection and analysis were difficult to detect. The logging has been improved so that more information about e.g. imported and missing modules is printed to the html log files.
Own Id: OTP-8163 Aux Id: seq11374
The Common Test HTML overview pages have been improved. It is now possible to see if a test case has been skipped explicitly or because a configuration function has failed. Also, the history page (all_runs.html) now has scrolling text displaying the test names. The old format (showing names as a truncated string) can still be generated by means of the flag/option 'basic_html'.
Own Id: OTP-8177
Various corrections and improvements of Common Test and Test Server.
Own Id: OTP-7981
Minor updates and corrections.
Own Id: OTP-7897
The conf case in Test Server has been extended with properties that make it possible to execute test cases in parallel, in sequence and in shuffled order. It is now also possible to repeat test cases according to different criterias. The properties can be combined, making it possible to e.g. repeat a conf case a certain number of times and execute the test cases in different (random) order every time. The properties are specified in a list in the conf case definition: {conf, Properties, InitCase, TestCases, EndCase}. The available properties are: parallel, sequence, shuffle, repeat, repeat_until_all_ok, repeat_until_any_ok, repeat_until_any_fail, repeat_until_all_fail.
Own Id: OTP-7511 Aux Id: OTP-7839
The test server starts Cover on nodes of the same version as the test server itself only.
Own Id: OTP-7699
The Erlang mode for Emacs has been updated with new and modified skeletons for Common Test and TS. Syntax for test case groups in Common Test (and conf cases with properties in TS) has been added and a new minimal Common Test suite skeleton has been introduced.
Own Id: OTP-7856
The step functionality in Common Test (based on interaction with Debugger) was broken. This has been fixed, and some new step features have also been added. Please see the Common Test User's Guide for details.
Own Id: OTP-7800 Aux Id: seq11106
Miscellaneous updates.
Own Id: OTP-7527
When a testcase terminated due to a timetrap, io sent to the group leader from framework:end_tc/3 (using ct:pal/2/3 or ct:log/2/3) would cause deadlock. This has been fixed.
Own Id: OTP-7447 Aux Id: seq11010
Various updates and improvements, plus some minor bug fixes, have been implemented in Common Test and Test Server.
Own Id: OTP-7112
It is now possible, by means of the new function ct:abort_current_testcase/1 or test_server_ctrl:abort_current_testcase/1, to abort the currently executing test case.
Own Id: OTP-7518 Aux Id: OTP-7112
The scale factor returned by
Own Id: OTP-7175
When init_per_suite or end_per_suite terminated due to runtime failure, test_server failed to format the line number information properly and crashed. This error has now been fixed.
Own Id: OTP-7091
Test Server is a portable test server for automated application testing. The server can run test suites on local or remote targets and log progress and results to HTML pages. The main purpose of Test Server is to act as engine inside customized test tools. A callback interface for such framework applications is provided.
Own Id: OTP-6989