Age | Commit message (Collapse) | Author |
|
Rework the cowboy_http_req:parse_header/2 function while I was at it.
|
|
|
|
Update README.md
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This function doesn't try to add any additional header besides the
Connection: Upgrade header. It also doesn't accept a body.
It should be used for the intermediate reply to an upgrade process,
before the real reply is sent (if any, for example when using TLS).
|
|
Fixed according to the websocket draft specs.
|
|
|
|
Allows to limit the size of request and header lines, thus preventing
Cowboy from infinitely reading from the socket and never finding an
end of line.
Defaults to 4096 bytes.
|
|
|
|
Introduce cowboy_http's list/2, nonempty_list/2, token/2 functions.
|
|
New functions are reply/2, reply/3, chunked_reply/2 in cowboy_http_req.
|
|
|
|
|
|
|
|
This however does not fix the related Dialyzer warnings.
I have no idea what the warnings are about nor how to fix them,
so feel free to work on it and submit a patch!
|
|
Now init/3 can return one of the following values to enable loops:
- {loop, Req, State}
- {loop, Req, State, hibernate}
- {loop, Req, State, Timeout}
- {loop, Req, State, Timeout, hibernate}
Returning one of these tuples will activate looping in the HTTP handler.
When looping, handle/2 is never called. Instead, Cowboy will listen
for Erlang messages and forward them to the info/3 function of the
handler. If a timeout is defined, Cowboy will also close the connection
when no message has been received for Timeout milliseconds.
The info/3 function is defined as info(Msg, Req, State). It can return
either of the following tuples:
- {ok, Req, State}
- {loop, Req, State}
- {loop, Req, State, hibernate}
The first one ends the connection, calling terminate/2 before closing.
The others continue the loop.
Loops are useful when writing long-polling handlers that need to wait
and don't expect to receive anything. Therefore it is recommended to
set a timeout to close the connection if nothing arrives after a while
and to enable hibernate everywhere.
Normal HTTP handlers shouldn't need to use this and as such info/3
was made optional.
|
|
This change allows application developers to refuse websocket upgrades
by returning {shutdown, Req}. The application can also send a reply
with a custom error before returning from websocket_init/3, otherwise
an error 400 is sent.
Note that right now Cowboy closes the connection immediately. Also note
that neither terminate/3 nor websocket_terminate/3 will be called when
the connection is shutdown by websocket_init/3.
|
|
|
|
|
|
This new exported function returns a Child Spec suitable for embedding
cowboy in another applications supervisor structure. While here,
implement `start_listener/6` in terms of it.
|
|
|
|
You can now return {shutdown, Req, State} from Handler:init/3
to skip the handle/2 step.
Also allow init/3 function to send responses.
|
|
|
|
|
|
|
|
Now Cowboy checks headers sent to the client for the 'Connection'
header value, parses it, and checks whether it contains a 'close'
or 'keep-alive' value. It makes sure to close or keep the connection
alive depending on the value found there, if any.
Also change chunked replies to not close the connection by default
unless the application requests it.
|
|
I know it is unlikely to use plain TCP on port 443, where SSL is
usually used, but a bug is still a bug, and as such it should be fixed.
Now the port will be probably appended to the location when port 443
is used without SSL.
|
|
Also add a call to compact/1 in the websocket test handler so we may
catch bugs related to it faster later on.
|
|
From the RFC:
The HEAD method is identical to GET except that the server MUST NOT
return a message-body in the response. The metainformation contained
in the HTTP headers in response to a HEAD request SHOULD be identical
to the information sent in response to a GET request.
|
|
|
|
Replaces the 'Connection' interpretation in cowboy_http_protocol
from raw value to the parsed value, looking for a single token
matching close/keep-alive instead of the whole raw value (which
could contain more than one token, for example with Firefox 6+
using websocket).
Introduce the functions cowboy_http_req:parse_header/2 and /3
to semantically parse the header values and return a proper
Erlang term.
|
|
|
|
Use the Req connection information instead.
|
|
And use a proper cowboy_http_req:reply/4 call for the 204 response.
|
|
|
|
The server should not send a response if there wasn't at least
the beginning of a request sent (the Request-Line).
|
|
If the websocket frame handling code in cowboy_http_websocket receives
only 1 byte at a time, it fails with a badmatch in
cowboy_http_websocket:websocket_data/4. This commit fixes the problem
and introduces a test of the correct behaviour.
|
|
Thanks to @nivertech for pointing it out in ticket #61.
|
|
Thanks to @klaar for pointing it out in ticket #59.
|
|
|
|
|
|
|
|
|
|
|
|
Making it look more like the websocket handler error messages.
|