aboutsummaryrefslogtreecommitdiffstats
path: root/test/handlers
AgeCommit message (Collapse)Author
2022-12-05Add tests for ws subprotocol negotiationViktor Söderqvist
2022-09-12Update cookie tests against latest WPTLoïc Hoguin
The http-state tests were removed and replaced with tests in HTML pages. I have devised a way to semi- automatically import them and test them. Additional fixes were made following changes in the rfc6265bis draft.
2022-08-30Add tests for the SSE handlerBenedikt Reinartz
2021-02-07Initial commit for Gun poolsLoïc Hoguin
The approach taken here is very similar to what browsers are doing. A separate pool is created for each host/port/scope. The authority (host header) is used to determine which pool will execute requests. A connection process is semi-randomly chosen, from the connections that have capacity. Maximum capacity is determined by the protocol (the HTTP/2 setting set by the server is used, for example). Multiple processes can process requests/responses on the same connection concurrently. There is no need to "give back" the response to the pool, the number of ongoing streams is maintained via an event handler. The implementation is currently not strict, there may be more attempts to create requests than there is capacity. I'm not sure if it should be made strict or if Gun should just wait before sending requests (it only matters in the HTTP/2 case at the moment). When there is no connection with capacity available in the pool (because they have too many streams, or are reconnecting, or any other reason), checking out fails. There is no timeout to wait for a connection to be available. On the other hand the checkout_retry option allows setting multiple timeouts to retry checking out a connection. Each retry attempt's wait time can have a different value. The initial implementation of this work was sponsored by Kobil and made at the suggestion of Ilya Khaprov.
2020-10-03Add tunnel_SUITE testing all 3-layer combinationsLoïc Hoguin
The test suite is 216 tests with a tunnel created via two proxies leading to one origin server. The tests are for example socks5_h2_https where socks5 identifies the first SOCKS5 proxy, h2 the second HTTP/2 CONNECT proxy and https the secure HTTP/1.1 origin server. The test not only sets up the tunnel and does a request (or sends/receives data in the case of raw origin servers) but also confirms that the stream_info and info data is correct.
2020-09-21Add HTTP/2 CONNECT tests with Cowboy as originLoïc Hoguin
2020-04-16Add tests for cookie_ignore_informational optionLoïc Hoguin
2020-03-12Make Gun use the cookie store when configured toLoïc Hoguin
2019-09-05Implement graceful shutdownLoïc Hoguin
The graceful shutdown is implemented through a new 'closing' state. This state is entered under different circumstances depending on the protocol. The gun:shutdown/1 function is now implemented and documented. It allows shutting down the connection gracefully regardless of the current state of the connection and for all protocols. The behavior is entirely dependent on the protocol. For HTTP/1.1 the connection stays up only until after the current stream is complete; other streams are immediately canceled. For HTTP/2 a GOAWAY frame is sent and existing streams continue to be processed. The connection is closed after all streams are processed and the server's GOAWAY frame is received. For Websocket a close frame is sent. The connection is closed when receiving the server's close frame. In all cases the closing_timeout option defines how long we wait, as a maximum, before closing the connection after the graceful shutdown was started. The graceful shutdown is also initiated when the owner process goes away; when sending an HTTP/1.1 request with the connection: close header; when receiving an HTTP/1.1 response with the connection: close header; when receiving an HTTP/1.0 response without a connection header; when the server sends a GOAWAY HTTP/2 frame; or when we send or receive a Websocket close frame. Along with these changes, the gun:ws_send/2 function now accepts a list of frames as argument. Those frames may include a close frame that initiates the graceful shutdown.
2019-08-05Add flow controlLoïc Hoguin
Flow control is disabled by default. The initial flow value must be set to enable it (either for the entire connection or on a per-request basis). Flow applies to all HTTP streams as well as Websocket. HTTP/2 pushed streams receive the same value as their originating stream.
2019-07-25Rename ws_echo test handler to ws_echo_hLoïc Hoguin
2019-07-24Add push_promise_start/push_promise_end eventsLoïc Hoguin
2019-07-02Add response_inform/response_headers/response_end eventsLoïc Hoguin
This covers many scenarios but more need to be added.
2018-12-31Fix stripping stream reference in gun_httpPiotr Bober
An invalid stream reference (the websocket tuple wrapper) was sent in the gun_data message. Also moves autobahn to its own test suite.
2018-10-11Make all the gun_SUITE test self-reliableLoïc Hoguin
Some intermittent failures occurred because of trying to connect to google.com or echo.websocket.org.
2018-08-09Add an SSE test for lone id: linesLoïc Hoguin
2018-08-06Make sse_SUITE work for older OTP versionsLoïc Hoguin
2018-08-06Rewrite the SSE suite using CowboyLoïc Hoguin