aboutsummaryrefslogblamecommitdiffstats
path: root/lib/sasl/doc/src/alarm_handler.xml
blob: 87be6d2a9e87b3fa17abe7cc8a6565bdcfec6f7a (plain) (tree)
1
2
3
4
5
6
7
8





                                        
                       



















































































































                                                                                                                                                                                          
<?xml version="1.0" encoding="latin1" ?>
<!DOCTYPE erlref SYSTEM "erlref.dtd">

<erlref>
  <header>
    <copyright>
      <year>1996</year>
      <year>2011</year>
      <holder>Ericsson AB, All Rights Reserved</holder>
    </copyright>
    <legalnotice>
  The contents of this file are subject to the Erlang Public License,
  Version 1.1, (the "License"); you may not use this file except in
  compliance with the License. You should have received a copy of the
  Erlang Public License along with this software. If not, it can be
  retrieved online at http://www.erlang.org/.

  Software distributed under the License is distributed on an "AS IS"
  basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See
  the License for the specific language governing rights and limitations
  under the License.

  The Initial Developer of the Original Code is Ericsson AB.
    </legalnotice>

    <title>alarm_handler</title>
    <prepared>Martin Bj&ouml;rklund</prepared>
    <responsible>Bjarne Dacker</responsible>
    <docno></docno>
    <approved>Bjarne D&auml;cker</approved>
    <checked>Martin Bj&ouml;rklund</checked>
    <date>1996-09-10</date>
    <rev>A</rev>
    <file>alarm_handler.sgml.t1</file>
  </header>
  <module>alarm_handler</module>
  <modulesummary>An Alarm Handling Process</modulesummary>
  <description>
    <p>The alarm handler process is a <c>gen_event</c> event manager
      process which receives alarms in the system. This process is not
      intended to be a complete alarm handler. It defines a
      place to which alarms can be sent. One simple event handler is
      installed in the alarm handler at start-up, but users are
      encouraged to write and install their own handlers.
      </p>
    <p>The simple event handler sends all alarms as info reports to
      the error logger, and saves all of them in a list which can be
      passed to a user defined event handler, which may be installed at
      a later stage. The list can grow large if many alarms are
      generated. So it is a good reason to install a better user defined
      handler.
      </p>
    <p>There are functions to set and clear alarms. The format of
      alarms are defined by the user. For example, an event handler
      for SNMP could be defined, together with an alarm MIB.
      </p>
    <p>The alarm handler is part of the SASL application. 
      </p>
    <p>When writing new event handlers for the alarm handler, the
      following events must be handled:
      </p>
    <taglist>
      <tag><c>{set_alarm, {AlarmId, AlarmDescr}}</c></tag>
      <item>
        <p>This event is generated by
          <c>alarm_handler:set_alarm({AlarmId, AlarmDecsr})</c>.
          </p>
      </item>
      <tag><c>{clear_alarm, AlarmId}</c></tag>
      <item>
        <p>This event is
          generated by <c>alarm_handler:clear_alarm(AlarmId)</c>.
          </p>
      </item>
    </taglist>
    <p>The default simple handler is called <c>alarm_handler</c> and
      it may be exchanged by calling <c>gen_event:swap_handler/3</c>
      as <c>gen_event:swap_handler(alarm_handler, {alarm_handler, swap}, {NewHandler, Args})</c>. <c>NewHandler:init({Args, {alarm_handler, Alarms}})</c> is called. Refer to gen_event(3)
      for further details.
      </p>
  </description>
  <funcs>
    <func>
      <name>clear_alarm(AlarmId) -> void()</name>
      <fsummary>Clear the specified alarms</fsummary>
      <type>
        <v>AlarmId = term()</v>
      </type>
      <desc>
        <p>Clears all alarms with id <c>AlarmId</c>.
          </p>
      </desc>
    </func>
    <func>
      <name>get_alarms() -> [alarm()]</name>
      <fsummary>Get all active alarms</fsummary>
      <desc>
        <p>Returns a list of all active alarms. This function can only
          be used when the simple handler is installed.
          </p>
      </desc>
    </func>
    <func>
      <name>set_alarm(alarm())</name>
      <fsummary>Set an alarm with an id</fsummary>
      <type>
        <v>alarm() = {AlarmId, AlarmDescription}</v>
        <v>AlarmId = term()</v>
        <v>AlarmDescription = term()</v>
      </type>
      <desc>
        <p>Sets an alarm with id <c>AlarmId</c>. This id is used at a
          later stage when the alarm is cleared.
          </p>
      </desc>
    </func>
  </funcs>

  <section>
    <title>See Also</title>
    <p>error_logger(3), gen_event(3) 
      </p>
  </section>
</erlref>