authorJan Kloetzke <[email protected]>2012-07-31 21:08:31 +0200
committerJan Kloetzke <[email protected]>2012-07-31 21:21:49 +0200
commit03985084e42e262bac1b7c48a97c31db97348f1d (patch)
tree73ba2066f08aa478d48cc836e107ea7102329f9c /erts/doc/src
parent92eb89bd630e822cfc93a07dad7d6c7a25f45d63 (diff)
downloadotp-03985084e42e262bac1b7c48a97c31db97348f1d.tar.gz
otp-03985084e42e262bac1b7c48a97c31db97348f1d.tar.bz2
otp-03985084e42e262bac1b7c48a97c31db97348f1d.zip
erlsrv: gracefully stop emulator on Windows shutdown
Windows will send the SERVICE_CONTROL_SHUTDOWN event to the service control handler when shutting down the system. Instead of ignoring the event, erlsrv will now invoke the stop action. Likewise, the Erlang emulator (and it's port drivers) must not quit upon reception of the CTRL_SHUTDOWN_EVENT event in the console control handler.
Diffstat (limited to 'erts/doc/src')
-rw-r--r--erts/doc/src/erlsrv.xml13
1 files changed, 8 insertions, 5 deletions
diff --git a/erts/doc/src/erlsrv.xml b/erts/doc/src/erlsrv.xml
index c1ecbc7b77..b2f34ed247 100644
--- a/erts/doc/src/erlsrv.xml
+++ b/erts/doc/src/erlsrv.xml
@@ -357,11 +357,12 @@ The environment of an Erlang machine started
the console subsystem and programs running as window
applications. An application which runs in the console subsystem
(normal for port programs) uses the win32 function
- <c><![CDATA[SetConsoleCtrlHandler]]></c> to a control handler that returns
- TRUE in answer to the <c><![CDATA[CTRL_LOGOFF_EVENT]]></c>. Other
- applications just forward <c><![CDATA[WM_ENDSESSION]]></c> and
- <c><![CDATA[WM_QUERYENDSESSION]]></c> to the default window procedure. Here
- is a brief example in C of how to set the console control
+ <c><![CDATA[SetConsoleCtrlHandler]]></c> to register a control handler
+ that returns TRUE in answer to the <c><![CDATA[CTRL_LOGOFF_EVENT]]></c>
+ and <c><![CDATA[CTRL_SHUTDOWN_EVENT]]></c> events. Other applications
+ just forward <c><![CDATA[WM_ENDSESSION]]></c> and
+ <c><![CDATA[WM_QUERYENDSESSION]]></c> to the default window procedure.
+ Here is a brief example in C of how to set the console control
handler:</p>
<code type="none"><![CDATA[
#include <windows.h>
@@ -372,6 +373,8 @@ The environment of an Erlang machine started
BOOL WINAPI service_aware_handler(DWORD ctrl){
if(ctrl == CTRL_LOGOFF_EVENT)
return TRUE;
+ if(ctrl == CTRL_SHUTDOWN_EVENT)
+ return TRUE;
return FALSE;
}