diff options
author | Erlang/OTP <[email protected]> | 2012-01-24 14:12:16 +0100 |
---|---|---|
committer | Erlang/OTP <[email protected]> | 2012-01-24 14:12:16 +0100 |
commit | b55c3d29a3d9efce2ce6548963809fc3b7ab8729 (patch) | |
tree | b27cf0f5797c58df0fc5acc5da37683e341e5199 /lib/snmp/doc | |
parent | 7619b94a2c1098cbd176507b34d291806833a4b7 (diff) | |
parent | e447fc699d91456597cd38c0949dbc3872015e88 (diff) | |
download | otp-b55c3d29a3d9efce2ce6548963809fc3b7ab8729.tar.gz otp-b55c3d29a3d9efce2ce6548963809fc3b7ab8729.tar.bz2 otp-b55c3d29a3d9efce2ce6548963809fc3b7ab8729.zip |
Merge branch 'bmk/snmp/snmp4216_integration/r14' into maint-r14
* bmk/snmp/snmp4216_integration/r14:
[snmp] Releasse notes cleanup
[snmp/agent] Incorrect mib server cache gclimit update
[snmp] Updated doc and fixed wrequest create macros
[snmp] Be more verbose in the worker procs
[snmp] Add a more informative return value when the trap sending fails
[snmp] Fixed the mt_trap test-case
[snmp] Maximum number of varbinds in a Get-BULK response
[snmp] Correted the expect bug in the snmp test utility
[snmp] Mostly added some more verbosity stuff
Diffstat (limited to 'lib/snmp/doc')
-rw-r--r-- | lib/snmp/doc/src/notes.xml | 1138 | ||||
-rw-r--r-- | lib/snmp/doc/src/notes_history.xml | 1065 | ||||
-rw-r--r-- | lib/snmp/doc/src/snmp_app.xml | 109 | ||||
-rw-r--r-- | lib/snmp/doc/src/snmp_config.xml | 104 |
4 files changed, 1331 insertions, 1085 deletions
diff --git a/lib/snmp/doc/src/notes.xml b/lib/snmp/doc/src/notes.xml index 3edd78c00a..3a129a9c07 100644 --- a/lib/snmp/doc/src/notes.xml +++ b/lib/snmp/doc/src/notes.xml @@ -33,6 +33,65 @@ </header> <section> + <title>SNMP Development Toolkit 4.21.6</title> + <p>Version 4.21.6 supports code replacement in runtime from/to + version 4.21.5, 4.21.4, 4.21.3, 4.21.2, 4.21.1, 4.21, 4.20.1 and + 4.20. </p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>[agent] DoS attack using GET-BULK with large value of + MaxRepetitions. + A preventive method has been implementing by simply + limit the number of varbinds that can be included in + a Get-BULK response message. This is specified by the + new config option, + <seealso marker="snmp_app#agent_gb_max_vbs">gb_max_vbs</seealso>. + </p> + <p>Own Id: OTP-9700</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>[agent] Mib server cache gclimit update function incorrectly calls + age update function. + The gclimit update function, + <seealso marker="snmpa#update_mibs_cache_gclimit">update_mibs_cache_gclimit/1</seealso>, + <em>incorrectly</em> called the age update function, + <seealso marker="snmpa#update_mibs_cache_age">update_mibs_cache_age/2</seealso>. </p> + <p>Johan Claesson</p> + <p>Own Id: OTP-9868</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + + </section> <!-- 4.21.6 --> + + + <section> <title>SNMP Development Toolkit 4.21.5</title> <p>Version 4.21.5 supports code replacement in runtime from/to version 4.21.4, 4.21.3, 4.21.2, 4.21.1, 4.21, 4.20.1 and 4.20. </p> @@ -62,13 +121,13 @@ <list type="bulleted"> <item> <p>[agent] Repeated vacm table dumping fails due to file name - conflict. When dumping the vacm table to disk, a temoporary - file with a fixed name was used. If the table dumping - (snmpa_vacm:dump_table/0) was initiated from several different - processes in rapid succesion, the dumping could fail because the - different processes was simultaniously trying to write to the - same file. This problem has been eliminated by creating a unique - name for the temporary file. </p> + conflict. When dumping the vacm table to disk, a temoporary + file with a fixed name was used. If the table dumping + (snmpa_vacm:dump_table/0) was initiated from several different + processes in rapid succesion, the dumping could fail because the + different processes was simultaniously trying to write to the + same file. This problem has been eliminated by creating a unique + name for the temporary file. </p> <p>Own Id: OTP-9851</p> <p>Aux Id: Seq 11980</p> </item> @@ -703,1071 +762,6 @@ snmp_view_basec_acm_mib:vacmAccessTable(set, RowIndex, Cols). </section> <!-- 4.18 --> - <section> - <title>SNMP Development Toolkit 4.17.1</title> - <p>Version 4.17.1 supports code replacement in runtime from/to - version 4.17, 4.16.2, 4.16.1, 4.16, 4.15, 4.14 and 4.13.5.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <list type="bulleted"> - <item> - <p>When the function FilterMod:accept_recv/2 - returned false the SNMP agent stopped collecting - messages from UDP.</p> - <p>Own Id: OTP-8761</p> - </item> - </list> - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.17.1 --> - - - <section> - <title>SNMP Development Toolkit 4.17</title> - <p>Version 4.17 supports code replacement in runtime from/to - version 4.16.2, 4.16.1, 4.16, 4.15, 4.14 and 4.13.5.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] Added very basic support for multiple SNMPv3 - EngineIDs in a single agent. See - <seealso marker="snmpa#send_notification">send_notification/7</seealso>, - <seealso marker="snmpa_mpd#process_packet">process_packet/7</seealso>, - <seealso marker="snmpa_mpd#generate_response_msg">generate_response_msg/6</seealso> or - <seealso marker="snmpa_mpd#generate_msg">generate_msg/6</seealso> - for more info. </p> - - <p>Own Id: OTP-8478</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <p>-</p> - - <!-- - <list type="bulleted"> - <item> - <p>The config utility - (<seealso marker="snmp#config">snmp:config/0</seealso>) - generated a default notify.conf - with a bad name for the standard trap entry (was "stadard trap", - but should have been "standard trap"). This has been corrected. </p> - <p>Kenji Rikitake</p> - <p>Own Id: OTP-8433</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.17 --> - - - <section> - <title>SNMP Development Toolkit 4.16.2</title> - <p>Version 4.16.2 supports code replacement in runtime from/to - version 4.16.1, 4.16, 4.15, 4.14 and 4.13.5.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[compiler] The SMI specifies that a table row OID should be - named: { <tableIdentifier> "1" }. </p> - <p>A new option has been introduced, - <seealso marker="snmpc#compiler_opts">relaxed_row_name_assign_check</seealso>, - that allows for a more liberal numbering scheme</p> - <p>Own Id: OTP-8574</p> - </item> - - <item> - <p>[agent|manager] Changes to make snmp (forward) compatible with - the new version of the crypto application (released in R14). - As of R14, crypto is implemented using NIFs. Also, - the API is more strict. </p> - <p>Own Id: OTP-8594</p> - </item> - - <item> - <p>Auto [agent] Changed default value for the MIB server cache. - GC is now on by default. </p> - <p>Own Id: OTP-8648</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - - <list type="bulleted"> - <item> - <p>Encode/decode of Counter64 values larger than - 16#7fffffffffffffff (9223372036854775807) failed. </p> - <p>Own Id: OTP-8563</p> - </item> - - <item> - <p>[compiler] Fails to compile non-contiguous BITS. </p> - <p>Per Hedeland</p> - <p>Own Id: OTP-8595</p> - </item> - - <item> - <p>[manager] Raise condition causing the manager server process to - crash. Unregistering an agent while traffic (set/get-operations) - is ongoing could cause a crash in the manager server process - (raise condition). </p> - <p>Own Id: OTP-8646</p> - <p>Aux Id: Seq 11585</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.16.2 --> - - - <section> - <title>SNMP Development Toolkit 4.16.1</title> - <p>Version 4.16.1 supports code replacement in runtime from/to - version 4.16, 4.15, 4.14 and 4.13.5.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - <!-- - <list type="bulleted"> - <item> - <p>[agent|manager] Entries in the audit trail log can now be - augmented by a sequence number. </p> - <p>This is enabled by the <c>seqno</c> option, which is part of the - <seealso marker="snmp_config#audit_trail_log">Audit Trail Log</seealso> - config option. </p> - <p>See the - <seealso marker="snmp_app#configuration_params">reference manual</seealso> - or the - <seealso marker="snmp_config#configuration_params">Configuring the application</seealso> - chapter of the User's Guide for further info. </p> - - <p>Own Id: OTP-8395</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - - <list type="bulleted"> - <item> - <p>[manager] Fixed an upgrade/downgrade problem. </p> - <p>Upgrade/downgrade from/to 4.13.5 did not work for the net-if - process. This has now been fixed. </p> - <p>Own Id: OTP-8481</p> - </item> - - <item> - <p>[agent] A minor mnesia related performance improvement. </p> - <p>Own Id: OTP-8480</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.16.1 --> - - - <section> - <title>SNMP Development Toolkit 4.16</title> - <p>Version 4.16 supports code replacement in runtime from/to - version 4.15, 4.14 and 4.13.5.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent|manager] Entries in the audit trail log can now be - augmented by a sequence number. </p> - <p>This is enabled by the <c>seqno</c> option, which is part of the - <seealso marker="snmp_config#audit_trail_log">Audit Trail Log</seealso> - config option. </p> - <p>See the - <seealso marker="snmp_app#configuration_params">reference manual</seealso> - or the - <seealso marker="snmp_config#configuration_params">Configuring the application</seealso> - chapter of the User's Guide for further info. </p> - - <p>Own Id: OTP-8395</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - - <list type="bulleted"> - <item> - <p>[manager] Registration of agents using the config file, - <seealso marker="snmp_manager_config_files#agents">agents.conf</seealso>, - does not work. This has now been corrected. </p> - <p>Per Hedeland</p> - <p>Own Id: OTP-8442</p> - </item> - - <item> - <p>The config utility - (<seealso marker="snmp#config">snmp:config/0</seealso>) - generated a default notify.conf - with a bad name for the standard trap entry (was "stadard trap", - but should have been "standard trap"). This has been corrected. </p> - <p>Kenji Rikitake</p> - <p>Own Id: OTP-8433</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.16 --> - - - <section> - <title>SNMP Development Toolkit 4.15</title> - - <p>Version 4.15 supports code replacement in runtime from/to - version 4.14 and 4.13.5.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - - <list type="bulleted"> - <item> - <p>The documentation is now built with open source tools - (<em>xsltproc</em> and <em>fop</em>) that exists on most - platforms. One visible change is that the frames are removed.</p> - <p>Own Id: OTP-8249</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[manager] When information from an unknown agent is received, - it was previously delivered to the default user via calls to all - the functions of the callback API depending on the info type - (<c>pdu</c>, <c>trap</c>, <c>report</c> or <c>inform</c>). - The problem was that the <c>TargetName</c> argument was useless - in this case (only an already known agent has a known/valid - <c>TargetName</c>, but the <c>TargetName</c> used in these calls - was generated "on the fly"). </p> - <p>This has now been changed so that when a message is received - from an unknown agent, then only - <seealso marker="snmpm_user#handle_agent">handle_agent</seealso> - (for the default user) is called, but now this call also has a - <c>Type</c> argument, which is - <c>pdu | trap | report | inform</c>, depending on what kind of - message was actually received, thus making it possible for the - user to properly analyze the data received. </p> - <p>To handle this, the - <seealso marker="snmpm_user">snmpm_user</seealso> behaviour has - been updated. </p> - <p>*** POTENTIAL INCOMPATIBILITY ***</p> - <p>Own Id: OTP-8229</p> - <!-- <p>Aux Id: Seq 11312</p> --> - </item> - - </list> - - </section> - - </section> <!-- 4.15 --> - - - <section> - <title>SNMP Development Toolkit 4.14</title> - - <p>Version 4.14 supports code replacement in runtime from/to - version 4.13.5, 4.13.4, 4.13.3, 4.13.2, 4.13.1 and 4.13.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - - <list type="bulleted"> - <item> - <p>[compiler] Include object- and notification groups in the - compiled mib. - This will make it possible to import groups from other mibs. </p> - <p>Also the SNMPv2-MIB-file has been updated to a more - up-to-date version. </p> - <p>Own Id: OTP-8223</p> - <!-- <p>Aux Id: Seq 11383</p> --> - </item> - - <item> - <p>[manager] Added support for message filtering in the - network interface module provided with the application. - The component that actually make the filter decisions - is the network interface filter module. This module - must implement the - <seealso marker="snmpm_network_interface_filter">network interface filter behaviour</seealso> - for message filtering. - See also the Configuring chapter of - the User's Guide to see how to configure this feature. </p> - <p>See the - <seealso marker="snmp_app#configuration_params">configuration</seealso> - chapter for more info about the filter options.</p> - <p>Own Id: OTP-8228</p> - <p>Aux Id: Seq 11411</p> - </item> - - <item> - <p>The MIBs delivered as part of the application is now - also available as man pages, section 7. </p> - <p>Own Id: OTP-8237</p> - <!-- <p>Aux Id: Seq 11383</p> --> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <p>-</p> - - <!-- - <list type="bulleted"> - <item> - <p>[agent] The main agent type header file contained some miss-information - regarding the type of the entrytype field of the me-record, causing - unneccessary confusion.</p> - <p>Own Id: OTP-8116</p> - <p>Aux Id: Seq 11312</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.14 --> - - - <section> - <title>SNMP Development Toolkit 4.13.5</title> - - <p>Version 4.13.5 supports code replacement in runtime from/to - version 4.13.4, 4.13.3, 4.13.2, 4.13.1 and 4.13.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - - <list type="bulleted"> - <item> - <p>[agent] Improved the cache handling of the mib server. </p> - <p>A number of new functions and config options for the mib server - cache has been added. </p> - <p>See - <seealso marker="snmpa#invalidate_mibs_cache">invalidate_mibs_cache/0,1</seealso>, - <seealso marker="snmpa#enable_mibs_cache">enable_mibs_cache/0,1</seealso>, - <seealso marker="snmpa#disable_mibs_cache">disable_mibs_cache/0,1</seealso>, - <seealso marker="snmpa#gc_mibs_cache">gc_mibs_cache/0,1,2,3</seealso>, - <seealso marker="snmpa#enable_mibs_cache_autogc">enable_mibs_cache_autogc/0,1</seealso>, - <seealso marker="snmpa#disable_mibs_cache_autogc">disable_mibs_cache_autogc/0,1</seealso>, - <seealso marker="snmpa#update_mibs_cache_age">update_mibs_cache_age/1,2</seealso> and - <seealso marker="snmpa#update_mibs_cache_gclimit">update_mibs_cache_gclimit/1,2</seealso> for more info. </p> - <p>See also the - <seealso marker="snmp_app#configuration_params">configuration</seealso> - chapter for more info about the mib server cache options.</p> - <p>Own Id: OTP-8182</p> - <p>Aux Id: Seq 11383</p> - </item> - - <item> - <p>[agent] A manager could no longer use the SNMPv3 user "initial" - as this was interpretated as the first step of the discovery. </p> - <p>Introduced a new terminating option, <c>trigger_username</c> to - make it possible to configure the username the agent reacts to. - Default is <c>""</c>. </p> - <p>See the - <seealso marker="snmp_app#configuration_params">configuration</seealso> - chapter for more info about the discovery options.</p> - <p>Own Id: OTP-8120</p> - <p>Aux Id: Seq 11361</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] The main agent type header file contained some miss-information - regarding the type of the entrytype field of the me-record, causing - unneccessary confusion.</p> - <p>Own Id: OTP-8116</p> - <p>Aux Id: Seq 11312</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.13.5 --> - - - <section> - <title>SNMP Development Toolkit 4.13.4</title> - - <p>Version 4.13.4 supports code replacement in runtime from/to - version 4.13.3, 4.13.2, 4.13.1 and 4.13.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - - <!-- - <list type="bulleted"> - <item> - <p>[agent] Support for the discovery process. </p> - <p>The agent can both initiate discovery itself (see the - <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter - for more info) and respond to discovery initiated by a manager.</p> - <p>Own Id: OTP-7571</p> - <p>Aux Id: Seq 11053</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] Originating discovery problems. </p> - <p>Invalid state variable update during second stage of - discovery causes master agent crash. </p> - <p>Also the net_if process failed to activate socket - ({active, once}) after first discovery response was sent. </p> - <p>Own Id: OTP-8044</p> - <p>Aux Id: Seq 11295</p> - </item> - - <item> - <p>[agent] Terminating discovery problem. </p> - <p>The reply to the second stage request should include a - varbind with <c>usmStatsNotInTimeWindows</c>.</p> - <p>Own Id: OTP-8062</p> - <p>Aux Id: Seq 11318</p> - </item> - - <item> - <p>[agent] Originating discovery improvement. </p> - <p>Added the ExtraInfo argument to the - <seealso marker="snmpa#discovery">discovery</seealso> function. - This argument will be passed on to the stage1_finish callback - function. Also, the - <seealso marker="snmpa#discovery">discovery</seealso> function - will now always return <c>{ok, ManagerEngineID}</c> on successful - discovery. </p> - <p>The <seealso marker="snmpa_discovery_handler">discovery handler</seealso> - behaviour updated accordingly. </p> - <p>Own Id: OTP-8098</p> - <p>Aux Id: Seq 11346</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.13.4 --> - - - <section> - <title>SNMP Development Toolkit 4.13.3</title> - - <p>Version 4.13.3 supports code replacement in runtime from/to - version 4.13.2, 4.13.1 and 4.13.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - - <!-- - <list type="bulleted"> - <item> - <p>[agent] Support for the discovery process. </p> - <p>The agent can both initiate discovery itself (see the - <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter - for more info) and respond to discovery initiated by a manager.</p> - <p>Own Id: OTP-7571</p> - <p>Aux Id: Seq 11053</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[manager] A request for an oid of type BITS was actually - returned as OCTET STRING. </p> - <p>Values of type BITS are encoded as OCTET STRING, - which makes it impossible for the decoder to know that - they should really be of type BITS. - Instead, this has to be done higher up in the stack, where - there is knowledge of the MIB (assuming that the mib has - been loaded, there is info about the type of the mibentry). </p> - <p>This problem has now been fixed, but requires that the MIB - defining this mib-entry is loaded! </p> - <p>The utility function - <seealso marker="snmpm#oid_to_type">oid_to_type</seealso> - has been added, for debug purpose. </p> - <p>The utility function(s) - <seealso marker="snmp#octet_string_to_bits">octet_string_to_bits</seealso> - and - <seealso marker="snmp#bits_to_octet_string">bits_to_octet_string</seealso> - has also been added. These can be used if the user prefers to - handle the conversion on their own. </p> - <p>Own Id: OTP-8015</p> - <p>Aux Id: Seq 11285</p> - </item> - - <item> - <p>[agent] Fixed some issues with the discovery handling. </p> - <p>Changed the API of the - <seealso marker="snmpa#discovery">discovery</seealso> - function to solve some - of these problems. </p> - <p>Introduced various options for controlling the discovery - process. See the - <seealso marker="snmp_app#configuration_params">configuration</seealso> - chapter for more info about the discovery options.</p> - <p>Own Id: OTP-8020</p> - <p>Aux Id: Seq 11295</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.13.3 --> - - - <section> - <title>SNMP Development Toolkit 4.13.2</title> - - <p>Version 4.13.2 supports code replacement in runtime from/to - version 4.13.1 and 4.13.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - - <!-- - <list type="bulleted"> - <item> - <p>[agent] Support for the discovery process. </p> - <p>The agent can both initiate discovery itself (see the - <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter - for more info) and respond to discovery initiated by a manager.</p> - <p>Own Id: OTP-7571</p> - <p>Aux Id: Seq 11053</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[manager] Failure during downed user cleanup. - As part of the cleanup after a crashed user, - the manager attempts to unregister the agents - registered by this user. This however failed, - causing a server crash. </p> - <p>Own Id: OTP-7961</p> - <p>Aux Id: Seq 11275</p> - </item> - - <item> - <p>[manager] Incorrectly documented value type for - IpAddress (ip). The value type for IpAddress is - documented as ip but is actually ia. The value type - ip has been added. The old (not documented) value - type ia still works. </p> - <p>Own Id: OTP-7977</p> - <p>Aux Id: Seq 11279</p> - </item> - - <item> - <p>[manager] EngineId lookup fails when using version-3. </p> - <p>Own Id: OTP-7983</p> - <p>Aux Id: Seq 11275</p> - </item> - - <item> - <p>[agent] As of version 4.13 the possible return values - of the function - <seealso marker="snmpa_mpd#process_packet">snmpa_mpd:process_packet/4</seealso> - changed, but this was not documented. </p> - <p>Own Id: OTP-7989</p> - <p>Aux Id: Seq 11275</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.13.2 --> - - <section> - <title>SNMP Development Toolkit 4.13.1</title> - - <p>Version 4.13.1 supports code replacement in runtime from/to - version 4.13.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - - <!-- - <list type="bulleted"> - <item> - <p>[agent] Support for the discovery process. </p> - <p>The agent can both initiate discovery itself (see the - <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter - for more info) and respond to discovery initiated by a manager.</p> - <p>Own Id: OTP-7571</p> - <p>Aux Id: Seq 11053</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[manager] Registration of users had some issues. </p> - <p>Not all of the registration functions where actually exported - (<seealso marker="snmpm#register_user">register_user/4</seealso> - and - <seealso marker="snmpm#register_user_monitor">register_user_monitor/4</seealso>). - This has now been fixed. </p> - <p>Also, the registration did not succeed unless - user implemented the *new* behaviour. This has now - also been fixed (registration succeeds if the user - implements either the new (i.e. updated - <seealso marker="snmpm_user">snmpm_user</seealso>) - or the old user behaviour (<c>snmpm_user_old</c>)). </p> - <p>Own Id: OTP-7902</p> - <p>Aux Id: Seq 11240</p> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.13.1 --> - - <section> - <title>SNMP Development Toolkit 4.13</title> -<!-- - <p>Version 4.13 supports code replacement in runtime from/to - version 4.12.1.</p> ---> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] Support for the discovery process. </p> - <p>The agent can both initiate discovery itself (see the - <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter - for more info) and respond to discovery initiated by a manager.</p> - <p>Own Id: OTP-7571</p> - <p>Aux Id: Seq 11053</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] Unnecessary use of math:pow/2 could cause problems - on systems without floating point support. </p> - <p>Per Hedeland</p> - <p>Own Id: OTP-7735</p> - <!-- <p>Aux Id: Seq 10966</p> --> - </item> - - <item> - <p>[manager] A major flaw was discovered with the agent handling. </p> - <p>First, <c>TargetName</c> was never used as intended, as a unique - identifier for the target (agent in this case). </p> - <p>Second, <c>TargetName</c> had a <em>default value</em>, which meant - that several agents could have the same <c>TargetName</c>, causing - unpredictable behaviour in the manager. </p> - <p>Third, <c>EngineID</c> was not a mandatory config option and had - furthermore also a <em>default value</em>. </p> - - <p>These problems has been solved in the following way: </p> - <p>First, a new set of api functions has been introduced (and documented): - <seealso marker="snmpm#register_user">register_user/4</seealso>, - <seealso marker="snmpm#register_user_monitor">register_user_monitor/4</seealso>, - <seealso marker="snmpm#register_agent">register_agent/3</seealso>, - <seealso marker="snmpm#unregister_agent">unregister_agent/2</seealso>, - <seealso marker="snmpm#agent_info">agent_info/2</seealso>, - <seealso marker="snmpm#update_agent_info">update_agent_info/4</seealso>, - <seealso marker="snmpm#sync_get">sync_get/3,4,5,6</seealso>, - <seealso marker="snmpm#async_get">async_get/3,4,5,6</seealso>, - <seealso marker="snmpm#sync_get_next">sync_get_next/3,4,5,6</seealso>, - <seealso marker="snmpm#async_get_next">async_get_next/3,4,5,6</seealso>, - <seealso marker="snmpm#sync_set">sync_set/3,4,5,6</seealso>, - <seealso marker="snmpm#async_set">async_set/3,4,5,6</seealso>, - <seealso marker="snmpm#sync_get_bulk">sync_get_bulk/5,6,7,8</seealso> and - <seealso marker="snmpm#async_get_bulk">async_get_bulk/5,6,7,8</seealso> - that all use <c>TargetName</c> (and not, as previously, <c>Addr</c> - and <c>Port</c>) to identify the agent (also the return value of - <seealso marker="snmpm#which_agents">which_agents</seealso> has - been changed). </p> - <p>Second, for backward compatibility, the old functions still - exist, but are no longer documented and are now wrappers for the - new functions, including erroneous default value for EngineID and - all. The TargetName is however generated from the provided - <c>Addr</c>, <c>Port</c> and <c>Version</c> config options. </p> - <p>Third, the behaviour of the - <seealso marker="snmpm_user">SNMP manager user</seealso> has - been changed to reflect this, i.e. - <seealso marker="snmpm_user#handle_pdu">handle_pdu/4</seealso>, - <seealso marker="snmpm_user#handle_trap">handle_trap/3</seealso>, - <seealso marker="snmpm_user#handle_inform">handle_inform/3</seealso>, - <seealso marker="snmpm_user#handle_report">handle_report/3</seealso> - and the return-value of - <seealso marker="snmpm_user#handle_agent">handle_agent/4</seealso>. - The old (non-documented) callback-functions (using Addr and Port) - will still be called if the agent was registered using the old - registration functions. </p> - - <p>Own Id: OTP-7836</p> - <!-- <p>Aux Id: Seq 10966</p> --> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.13 --> - - <section> - <title>SNMP Development Toolkit 4.12.2</title> - <p>Version 4.12.2 supports code replacement in runtime from/to - version 4.12.1, 4.12, 4.11.2, 4.11.1 and 4.11.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - <!-- - <list type="bulleted"> - <item> - <item> - <p>[agent] Improvement of the inform reporting. - It was previously not certain how many acks an - application received, 0, 1 or 2. This has now been - fixed, so that only 1 (one) ack is issued. </p> - <p>Per Hedeland</p> - <p>Own Id: OTP-7525</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] Bad session cache (usm+camv-info) invalidation - could cause user crash, through call(s) to (a number of) - MIB API function(s) (undefined function). </p> - <p>Own Id: OTP-7868</p> - <!-- <p>Aux Id: Seq 11124</p> --> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.12.2 --> - - <section> - <title>SNMP Development Toolkit 4.12.1</title> - <p>Version 4.12.1 supports code replacement in runtime from/to - version 4.12, 4.11.2, 4.11.1 and 4.11.</p> - - <section> - <title>Improvements and new features</title> - <p>-</p> - <!-- - <list type="bulleted"> - <item> - <item> - <p>[agent] Improvement of the inform reporting. - It was previously not certain how many acks an - application received, 0, 1 or 2. This has now been - fixed, so that only 1 (one) ack is issued. </p> - <p>Per Hedeland</p> - <p>Own Id: OTP-7525</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>Logging of messages with the GetBulk-request PDU - incorrectly produced an erroneous entry in the - log: "An error occurred". </p> - <p>The reason for this was that the PDU-fields - error_status and error_index is re-used for - Non-repeaters and Max-repetitions for - GetBulk-request PDUs, but this was not handled - by the logging code. </p> - <p>Own Id: OTP-7695</p> - <p>Aux Id: Seq 11124</p> - </item> - - <item> - <p>[agent] An attempt to set the row status to active for an - notReady table row, could result in an "inconsistentValue" - error. </p> - <p>The same problem existed when attempting to set row status - to notInService for a row in notReady. </p> - <p>Serge Aleynikov</p> - <p>Own Id: OTP-7698</p> - <!-- <p>Aux Id: Seq 10966</p> --> - </item> - - </list> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.12.1 --> - - <section> - <title>SNMP Development Toolkit 4.12</title> - <p>Version 4.12 supports code replacement in runtime from/to - version 4.11.2, 4.11.1 and 4.11.</p> - - <section> - <title>Improvements and new features</title> - <!-- - <p>-</p> - --> - <list type="bulleted"> - <item> - <p>[agent] A simple lookup cache has been added to improve - the mib server lookup performance. </p> - <p>This can be disabled with the mib_server - <seealso marker="snmp_app">cache</seealso> option. </p> - <p>Own Id: OTP-7346</p> - </item> - - <item> - <p>[agent] Improvement of the inform reporting. - It was previously not certain how many acks an - application received, 0, 1 or 2. This has now been - fixed, so that only 1 (one) ack is issued. </p> - <p>Per Hedeland</p> - <p>Own Id: OTP-7525</p> - </item> - - </list> - - </section> - - <section> - <title>Reported Fixed Bugs and Malfunctions</title> - <p>-</p> - <!-- - <list type="bulleted"> - <item> - <p>[manager] Encryption error when attempting to send - version 3 inform-requests. </p> - <p>Own Id: OTP-7432</p> - <p>Aux Id: Seq 10966</p> - </item> - - </list> - --> - - </section> - - <section> - <title>Incompatibilities</title> - <p>-</p> - </section> - </section> <!-- 4.12 --> - <!-- section> <title>Release notes history</title> <p>For information about older versions see diff --git a/lib/snmp/doc/src/notes_history.xml b/lib/snmp/doc/src/notes_history.xml index e8dcbae528..023717cd7c 100644 --- a/lib/snmp/doc/src/notes_history.xml +++ b/lib/snmp/doc/src/notes_history.xml @@ -33,6 +33,1071 @@ </header> <section> + <title>SNMP Development Toolkit 4.17.1</title> + <p>Version 4.17.1 supports code replacement in runtime from/to + version 4.17, 4.16.2, 4.16.1, 4.16, 4.15, 4.14 and 4.13.5.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <list type="bulleted"> + <item> + <p>When the function FilterMod:accept_recv/2 + returned false the SNMP agent stopped collecting + messages from UDP.</p> + <p>Own Id: OTP-8761</p> + </item> + </list> + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.17.1 --> + + + <section> + <title>SNMP Development Toolkit 4.17</title> + <p>Version 4.17 supports code replacement in runtime from/to + version 4.16.2, 4.16.1, 4.16, 4.15, 4.14 and 4.13.5.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] Added very basic support for multiple SNMPv3 + EngineIDs in a single agent. See + <seealso marker="snmpa#send_notification">send_notification/7</seealso>, + <seealso marker="snmpa_mpd#process_packet">process_packet/7</seealso>, + <seealso marker="snmpa_mpd#generate_response_msg">generate_response_msg/6</seealso> or + <seealso marker="snmpa_mpd#generate_msg">generate_msg/6</seealso> + for more info. </p> + + <p>Own Id: OTP-8478</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <p>-</p> + + <!-- + <list type="bulleted"> + <item> + <p>The config utility + (<seealso marker="snmp#config">snmp:config/0</seealso>) + generated a default notify.conf + with a bad name for the standard trap entry (was "stadard trap", + but should have been "standard trap"). This has been corrected. </p> + <p>Kenji Rikitake</p> + <p>Own Id: OTP-8433</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.17 --> + + + <section> + <title>SNMP Development Toolkit 4.16.2</title> + <p>Version 4.16.2 supports code replacement in runtime from/to + version 4.16.1, 4.16, 4.15, 4.14 and 4.13.5.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[compiler] The SMI specifies that a table row OID should be + named: { <tableIdentifier> "1" }. </p> + <p>A new option has been introduced, + <seealso marker="snmpc#compiler_opts">relaxed_row_name_assign_check</seealso>, + that allows for a more liberal numbering scheme</p> + <p>Own Id: OTP-8574</p> + </item> + + <item> + <p>[agent|manager] Changes to make snmp (forward) compatible with + the new version of the crypto application (released in R14). + As of R14, crypto is implemented using NIFs. Also, + the API is more strict. </p> + <p>Own Id: OTP-8594</p> + </item> + + <item> + <p>Auto [agent] Changed default value for the MIB server cache. + GC is now on by default. </p> + <p>Own Id: OTP-8648</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>Encode/decode of Counter64 values larger than + 16#7fffffffffffffff (9223372036854775807) failed. </p> + <p>Own Id: OTP-8563</p> + </item> + + <item> + <p>[compiler] Fails to compile non-contiguous BITS. </p> + <p>Per Hedeland</p> + <p>Own Id: OTP-8595</p> + </item> + + <item> + <p>[manager] Raise condition causing the manager server process to + crash. Unregistering an agent while traffic (set/get-operations) + is ongoing could cause a crash in the manager server process + (raise condition). </p> + <p>Own Id: OTP-8646</p> + <p>Aux Id: Seq 11585</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.16.2 --> + + + <section> + <title>SNMP Development Toolkit 4.16.1</title> + <p>Version 4.16.1 supports code replacement in runtime from/to + version 4.16, 4.15, 4.14 and 4.13.5.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + <!-- + <list type="bulleted"> + <item> + <p>[agent|manager] Entries in the audit trail log can now be + augmented by a sequence number. </p> + <p>This is enabled by the <c>seqno</c> option, which is part of the + <seealso marker="snmp_config#audit_trail_log">Audit Trail Log</seealso> + config option. </p> + <p>See the + <seealso marker="snmp_app#configuration_params">reference manual</seealso> + or the + <seealso marker="snmp_config#configuration_params">Configuring the application</seealso> + chapter of the User's Guide for further info. </p> + + <p>Own Id: OTP-8395</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>[manager] Fixed an upgrade/downgrade problem. </p> + <p>Upgrade/downgrade from/to 4.13.5 did not work for the net-if + process. This has now been fixed. </p> + <p>Own Id: OTP-8481</p> + </item> + + <item> + <p>[agent] A minor mnesia related performance improvement. </p> + <p>Own Id: OTP-8480</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.16.1 --> + + + <section> + <title>SNMP Development Toolkit 4.16</title> + <p>Version 4.16 supports code replacement in runtime from/to + version 4.15, 4.14 and 4.13.5.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent|manager] Entries in the audit trail log can now be + augmented by a sequence number. </p> + <p>This is enabled by the <c>seqno</c> option, which is part of the + <seealso marker="snmp_config#audit_trail_log">Audit Trail Log</seealso> + config option. </p> + <p>See the + <seealso marker="snmp_app#configuration_params">reference manual</seealso> + or the + <seealso marker="snmp_config#configuration_params">Configuring the application</seealso> + chapter of the User's Guide for further info. </p> + + <p>Own Id: OTP-8395</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>[manager] Registration of agents using the config file, + <seealso marker="snmp_manager_config_files#agents">agents.conf</seealso>, + does not work. This has now been corrected. </p> + <p>Per Hedeland</p> + <p>Own Id: OTP-8442</p> + </item> + + <item> + <p>The config utility + (<seealso marker="snmp#config">snmp:config/0</seealso>) + generated a default notify.conf + with a bad name for the standard trap entry (was "stadard trap", + but should have been "standard trap"). This has been corrected. </p> + <p>Kenji Rikitake</p> + <p>Own Id: OTP-8433</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.16 --> + + + <section> + <title>SNMP Development Toolkit 4.15</title> + + <p>Version 4.15 supports code replacement in runtime from/to + version 4.14 and 4.13.5.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>The documentation is now built with open source tools + (<em>xsltproc</em> and <em>fop</em>) that exists on most + platforms. One visible change is that the frames are removed.</p> + <p>Own Id: OTP-8249</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[manager] When information from an unknown agent is received, + it was previously delivered to the default user via calls to all + the functions of the callback API depending on the info type + (<c>pdu</c>, <c>trap</c>, <c>report</c> or <c>inform</c>). + The problem was that the <c>TargetName</c> argument was useless + in this case (only an already known agent has a known/valid + <c>TargetName</c>, but the <c>TargetName</c> used in these calls + was generated "on the fly"). </p> + <p>This has now been changed so that when a message is received + from an unknown agent, then only + <seealso marker="snmpm_user#handle_agent">handle_agent</seealso> + (for the default user) is called, but now this call also has a + <c>Type</c> argument, which is + <c>pdu | trap | report | inform</c>, depending on what kind of + message was actually received, thus making it possible for the + user to properly analyze the data received. </p> + <p>To handle this, the + <seealso marker="snmpm_user">snmpm_user</seealso> behaviour has + been updated. </p> + <p>*** POTENTIAL INCOMPATIBILITY ***</p> + <p>Own Id: OTP-8229</p> + <!-- <p>Aux Id: Seq 11312</p> --> + </item> + + </list> + + </section> + + </section> <!-- 4.15 --> + + + <section> + <title>SNMP Development Toolkit 4.14</title> + + <p>Version 4.14 supports code replacement in runtime from/to + version 4.13.5, 4.13.4, 4.13.3, 4.13.2, 4.13.1 and 4.13.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>[compiler] Include object- and notification groups in the + compiled mib. + This will make it possible to import groups from other mibs. </p> + <p>Also the SNMPv2-MIB-file has been updated to a more + up-to-date version. </p> + <p>Own Id: OTP-8223</p> + <!-- <p>Aux Id: Seq 11383</p> --> + </item> + + <item> + <p>[manager] Added support for message filtering in the + network interface module provided with the application. + The component that actually make the filter decisions + is the network interface filter module. This module + must implement the + <seealso marker="snmpm_network_interface_filter">network interface filter behaviour</seealso> + for message filtering. + See also the Configuring chapter of + the User's Guide to see how to configure this feature. </p> + <p>See the + <seealso marker="snmp_app#configuration_params">configuration</seealso> + chapter for more info about the filter options.</p> + <p>Own Id: OTP-8228</p> + <p>Aux Id: Seq 11411</p> + </item> + + <item> + <p>The MIBs delivered as part of the application is now + also available as man pages, section 7. </p> + <p>Own Id: OTP-8237</p> + <!-- <p>Aux Id: Seq 11383</p> --> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <p>-</p> + + <!-- + <list type="bulleted"> + <item> + <p>[agent] The main agent type header file contained some miss-information + regarding the type of the entrytype field of the me-record, causing + unneccessary confusion.</p> + <p>Own Id: OTP-8116</p> + <p>Aux Id: Seq 11312</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.14 --> + + + <section> + <title>SNMP Development Toolkit 4.13.5</title> + + <p>Version 4.13.5 supports code replacement in runtime from/to + version 4.13.4, 4.13.3, 4.13.2, 4.13.1 and 4.13.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + + <list type="bulleted"> + <item> + <p>[agent] Improved the cache handling of the mib server. </p> + <p>A number of new functions and config options for the mib server + cache has been added. </p> + <p>See + <seealso marker="snmpa#invalidate_mibs_cache">invalidate_mibs_cache/0,1</seealso>, + <seealso marker="snmpa#enable_mibs_cache">enable_mibs_cache/0,1</seealso>, + <seealso marker="snmpa#disable_mibs_cache">disable_mibs_cache/0,1</seealso>, + <seealso marker="snmpa#gc_mibs_cache">gc_mibs_cache/0,1,2,3</seealso>, + <seealso marker="snmpa#enable_mibs_cache_autogc">enable_mibs_cache_autogc/0,1</seealso>, + <seealso marker="snmpa#disable_mibs_cache_autogc">disable_mibs_cache_autogc/0,1</seealso>, + <seealso marker="snmpa#update_mibs_cache_age">update_mibs_cache_age/1,2</seealso> and + <seealso marker="snmpa#update_mibs_cache_gclimit">update_mibs_cache_gclimit/1,2</seealso> for more info. </p> + <p>See also the + <seealso marker="snmp_app#configuration_params">configuration</seealso> + chapter for more info about the mib server cache options.</p> + <p>Own Id: OTP-8182</p> + <p>Aux Id: Seq 11383</p> + </item> + + <item> + <p>[agent] A manager could no longer use the SNMPv3 user "initial" + as this was interpretated as the first step of the discovery. </p> + <p>Introduced a new terminating option, <c>trigger_username</c> to + make it possible to configure the username the agent reacts to. + Default is <c>""</c>. </p> + <p>See the + <seealso marker="snmp_app#configuration_params">configuration</seealso> + chapter for more info about the discovery options.</p> + <p>Own Id: OTP-8120</p> + <p>Aux Id: Seq 11361</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] The main agent type header file contained some miss-information + regarding the type of the entrytype field of the me-record, causing + unneccessary confusion.</p> + <p>Own Id: OTP-8116</p> + <p>Aux Id: Seq 11312</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.13.5 --> + + + <section> + <title>SNMP Development Toolkit 4.13.4</title> + + <p>Version 4.13.4 supports code replacement in runtime from/to + version 4.13.3, 4.13.2, 4.13.1 and 4.13.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + + <!-- + <list type="bulleted"> + <item> + <p>[agent] Support for the discovery process. </p> + <p>The agent can both initiate discovery itself (see the + <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter + for more info) and respond to discovery initiated by a manager.</p> + <p>Own Id: OTP-7571</p> + <p>Aux Id: Seq 11053</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] Originating discovery problems. </p> + <p>Invalid state variable update during second stage of + discovery causes master agent crash. </p> + <p>Also the net_if process failed to activate socket + ({active, once}) after first discovery response was sent. </p> + <p>Own Id: OTP-8044</p> + <p>Aux Id: Seq 11295</p> + </item> + + <item> + <p>[agent] Terminating discovery problem. </p> + <p>The reply to the second stage request should include a + varbind with <c>usmStatsNotInTimeWindows</c>.</p> + <p>Own Id: OTP-8062</p> + <p>Aux Id: Seq 11318</p> + </item> + + <item> + <p>[agent] Originating discovery improvement. </p> + <p>Added the ExtraInfo argument to the + <seealso marker="snmpa#discovery">discovery</seealso> function. + This argument will be passed on to the stage1_finish callback + function. Also, the + <seealso marker="snmpa#discovery">discovery</seealso> function + will now always return <c>{ok, ManagerEngineID}</c> on successful + discovery. </p> + <p>The <seealso marker="snmpa_discovery_handler">discovery handler</seealso> + behaviour updated accordingly. </p> + <p>Own Id: OTP-8098</p> + <p>Aux Id: Seq 11346</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.13.4 --> + + + <section> + <title>SNMP Development Toolkit 4.13.3</title> + + <p>Version 4.13.3 supports code replacement in runtime from/to + version 4.13.2, 4.13.1 and 4.13.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + + <!-- + <list type="bulleted"> + <item> + <p>[agent] Support for the discovery process. </p> + <p>The agent can both initiate discovery itself (see the + <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter + for more info) and respond to discovery initiated by a manager.</p> + <p>Own Id: OTP-7571</p> + <p>Aux Id: Seq 11053</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[manager] A request for an oid of type BITS was actually + returned as OCTET STRING. </p> + <p>Values of type BITS are encoded as OCTET STRING, + which makes it impossible for the decoder to know that + they should really be of type BITS. + Instead, this has to be done higher up in the stack, where + there is knowledge of the MIB (assuming that the mib has + been loaded, there is info about the type of the mibentry). </p> + <p>This problem has now been fixed, but requires that the MIB + defining this mib-entry is loaded! </p> + <p>The utility function + <seealso marker="snmpm#oid_to_type">oid_to_type</seealso> + has been added, for debug purpose. </p> + <p>The utility function(s) + <seealso marker="snmp#octet_string_to_bits">octet_string_to_bits</seealso> + and + <seealso marker="snmp#bits_to_octet_string">bits_to_octet_string</seealso> + has also been added. These can be used if the user prefers to + handle the conversion on their own. </p> + <p>Own Id: OTP-8015</p> + <p>Aux Id: Seq 11285</p> + </item> + + <item> + <p>[agent] Fixed some issues with the discovery handling. </p> + <p>Changed the API of the + <seealso marker="snmpa#discovery">discovery</seealso> + function to solve some + of these problems. </p> + <p>Introduced various options for controlling the discovery + process. See the + <seealso marker="snmp_app#configuration_params">configuration</seealso> + chapter for more info about the discovery options.</p> + <p>Own Id: OTP-8020</p> + <p>Aux Id: Seq 11295</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.13.3 --> + + + <section> + <title>SNMP Development Toolkit 4.13.2</title> + + <p>Version 4.13.2 supports code replacement in runtime from/to + version 4.13.1 and 4.13.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + + <!-- + <list type="bulleted"> + <item> + <p>[agent] Support for the discovery process. </p> + <p>The agent can both initiate discovery itself (see the + <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter + for more info) and respond to discovery initiated by a manager.</p> + <p>Own Id: OTP-7571</p> + <p>Aux Id: Seq 11053</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[manager] Failure during downed user cleanup. + As part of the cleanup after a crashed user, + the manager attempts to unregister the agents + registered by this user. This however failed, + causing a server crash. </p> + <p>Own Id: OTP-7961</p> + <p>Aux Id: Seq 11275</p> + </item> + + <item> + <p>[manager] Incorrectly documented value type for + IpAddress (ip). The value type for IpAddress is + documented as ip but is actually ia. The value type + ip has been added. The old (not documented) value + type ia still works. </p> + <p>Own Id: OTP-7977</p> + <p>Aux Id: Seq 11279</p> + </item> + + <item> + <p>[manager] EngineId lookup fails when using version-3. </p> + <p>Own Id: OTP-7983</p> + <p>Aux Id: Seq 11275</p> + </item> + + <item> + <p>[agent] As of version 4.13 the possible return values + of the function + <seealso marker="snmpa_mpd#process_packet">snmpa_mpd:process_packet/4</seealso> + changed, but this was not documented. </p> + <p>Own Id: OTP-7989</p> + <p>Aux Id: Seq 11275</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.13.2 --> + + <section> + <title>SNMP Development Toolkit 4.13.1</title> + + <p>Version 4.13.1 supports code replacement in runtime from/to + version 4.13.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + + <!-- + <list type="bulleted"> + <item> + <p>[agent] Support for the discovery process. </p> + <p>The agent can both initiate discovery itself (see the + <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter + for more info) and respond to discovery initiated by a manager.</p> + <p>Own Id: OTP-7571</p> + <p>Aux Id: Seq 11053</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[manager] Registration of users had some issues. </p> + <p>Not all of the registration functions where actually exported + (<seealso marker="snmpm#register_user">register_user/4</seealso> + and + <seealso marker="snmpm#register_user_monitor">register_user_monitor/4</seealso>). + This has now been fixed. </p> + <p>Also, the registration did not succeed unless + user implemented the *new* behaviour. This has now + also been fixed (registration succeeds if the user + implements either the new (i.e. updated + <seealso marker="snmpm_user">snmpm_user</seealso>) + or the old user behaviour (<c>snmpm_user_old</c>)). </p> + <p>Own Id: OTP-7902</p> + <p>Aux Id: Seq 11240</p> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.13.1 --> + + <section> + <title>SNMP Development Toolkit 4.13</title> +<!-- + <p>Version 4.13 supports code replacement in runtime from/to + version 4.12.1.</p> +--> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] Support for the discovery process. </p> + <p>The agent can both initiate discovery itself (see the + <seealso marker="snmp_agent_funct_descr#discovery">discovery</seealso> chapter + for more info) and respond to discovery initiated by a manager.</p> + <p>Own Id: OTP-7571</p> + <p>Aux Id: Seq 11053</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] Unnecessary use of math:pow/2 could cause problems + on systems without floating point support. </p> + <p>Per Hedeland</p> + <p>Own Id: OTP-7735</p> + <!-- <p>Aux Id: Seq 10966</p> --> + </item> + + <item> + <p>[manager] A major flaw was discovered with the agent handling. </p> + <p>First, <c>TargetName</c> was never used as intended, as a unique + identifier for the target (agent in this case). </p> + <p>Second, <c>TargetName</c> had a <em>default value</em>, which meant + that several agents could have the same <c>TargetName</c>, causing + unpredictable behaviour in the manager. </p> + <p>Third, <c>EngineID</c> was not a mandatory config option and had + furthermore also a <em>default value</em>. </p> + + <p>These problems has been solved in the following way: </p> + <p>First, a new set of api functions has been introduced (and documented): + <seealso marker="snmpm#register_user">register_user/4</seealso>, + <seealso marker="snmpm#register_user_monitor">register_user_monitor/4</seealso>, + <seealso marker="snmpm#register_agent">register_agent/3</seealso>, + <seealso marker="snmpm#unregister_agent">unregister_agent/2</seealso>, + <seealso marker="snmpm#agent_info">agent_info/2</seealso>, + <seealso marker="snmpm#update_agent_info">update_agent_info/4</seealso>, + <seealso marker="snmpm#sync_get">sync_get/3,4,5,6</seealso>, + <seealso marker="snmpm#async_get">async_get/3,4,5,6</seealso>, + <seealso marker="snmpm#sync_get_next">sync_get_next/3,4,5,6</seealso>, + <seealso marker="snmpm#async_get_next">async_get_next/3,4,5,6</seealso>, + <seealso marker="snmpm#sync_set">sync_set/3,4,5,6</seealso>, + <seealso marker="snmpm#async_set">async_set/3,4,5,6</seealso>, + <seealso marker="snmpm#sync_get_bulk">sync_get_bulk/5,6,7,8</seealso> and + <seealso marker="snmpm#async_get_bulk">async_get_bulk/5,6,7,8</seealso> + that all use <c>TargetName</c> (and not, as previously, <c>Addr</c> + and <c>Port</c>) to identify the agent (also the return value of + <seealso marker="snmpm#which_agents">which_agents</seealso> has + been changed). </p> + <p>Second, for backward compatibility, the old functions still + exist, but are no longer documented and are now wrappers for the + new functions, including erroneous default value for EngineID and + all. The TargetName is however generated from the provided + <c>Addr</c>, <c>Port</c> and <c>Version</c> config options. </p> + <p>Third, the behaviour of the + <seealso marker="snmpm_user">SNMP manager user</seealso> has + been changed to reflect this, i.e. + <seealso marker="snmpm_user#handle_pdu">handle_pdu/4</seealso>, + <seealso marker="snmpm_user#handle_trap">handle_trap/3</seealso>, + <seealso marker="snmpm_user#handle_inform">handle_inform/3</seealso>, + <seealso marker="snmpm_user#handle_report">handle_report/3</seealso> + and the return-value of + <seealso marker="snmpm_user#handle_agent">handle_agent/4</seealso>. + The old (non-documented) callback-functions (using Addr and Port) + will still be called if the agent was registered using the old + registration functions. </p> + + <p>Own Id: OTP-7836</p> + <!-- <p>Aux Id: Seq 10966</p> --> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.13 --> + + <section> + <title>SNMP Development Toolkit 4.12.2</title> + <p>Version 4.12.2 supports code replacement in runtime from/to + version 4.12.1, 4.12, 4.11.2, 4.11.1 and 4.11.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + <!-- + <list type="bulleted"> + <item> + <item> + <p>[agent] Improvement of the inform reporting. + It was previously not certain how many acks an + application received, 0, 1 or 2. This has now been + fixed, so that only 1 (one) ack is issued. </p> + <p>Per Hedeland</p> + <p>Own Id: OTP-7525</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] Bad session cache (usm+camv-info) invalidation + could cause user crash, through call(s) to (a number of) + MIB API function(s) (undefined function). </p> + <p>Own Id: OTP-7868</p> + <!-- <p>Aux Id: Seq 11124</p> --> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.12.2 --> + + <section> + <title>SNMP Development Toolkit 4.12.1</title> + <p>Version 4.12.1 supports code replacement in runtime from/to + version 4.12, 4.11.2, 4.11.1 and 4.11.</p> + + <section> + <title>Improvements and new features</title> + <p>-</p> + <!-- + <list type="bulleted"> + <item> + <item> + <p>[agent] Improvement of the inform reporting. + It was previously not certain how many acks an + application received, 0, 1 or 2. This has now been + fixed, so that only 1 (one) ack is issued. </p> + <p>Per Hedeland</p> + <p>Own Id: OTP-7525</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>Logging of messages with the GetBulk-request PDU + incorrectly produced an erroneous entry in the + log: "An error occurred". </p> + <p>The reason for this was that the PDU-fields + error_status and error_index is re-used for + Non-repeaters and Max-repetitions for + GetBulk-request PDUs, but this was not handled + by the logging code. </p> + <p>Own Id: OTP-7695</p> + <p>Aux Id: Seq 11124</p> + </item> + + <item> + <p>[agent] An attempt to set the row status to active for an + notReady table row, could result in an "inconsistentValue" + error. </p> + <p>The same problem existed when attempting to set row status + to notInService for a row in notReady. </p> + <p>Serge Aleynikov</p> + <p>Own Id: OTP-7698</p> + <!-- <p>Aux Id: Seq 10966</p> --> + </item> + + </list> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.12.1 --> + + <section> + <title>SNMP Development Toolkit 4.12</title> + <p>Version 4.12 supports code replacement in runtime from/to + version 4.11.2, 4.11.1 and 4.11.</p> + + <section> + <title>Improvements and new features</title> + <!-- + <p>-</p> + --> + <list type="bulleted"> + <item> + <p>[agent] A simple lookup cache has been added to improve + the mib server lookup performance. </p> + <p>This can be disabled with the mib_server + <seealso marker="snmp_app">cache</seealso> option. </p> + <p>Own Id: OTP-7346</p> + </item> + + <item> + <p>[agent] Improvement of the inform reporting. + It was previously not certain how many acks an + application received, 0, 1 or 2. This has now been + fixed, so that only 1 (one) ack is issued. </p> + <p>Per Hedeland</p> + <p>Own Id: OTP-7525</p> + </item> + + </list> + + </section> + + <section> + <title>Reported Fixed Bugs and Malfunctions</title> + <p>-</p> + <!-- + <list type="bulleted"> + <item> + <p>[manager] Encryption error when attempting to send + version 3 inform-requests. </p> + <p>Own Id: OTP-7432</p> + <p>Aux Id: Seq 10966</p> + </item> + + </list> + --> + + </section> + + <section> + <title>Incompatibilities</title> + <p>-</p> + </section> + </section> <!-- 4.12 --> + + <section> <title>SNMP Development Toolkit 4.11.2</title> <p>Version 4.11.2 supports code replacement in runtime from/to version 4.11.1 and 4.11. </p> diff --git a/lib/snmp/doc/src/snmp_app.xml b/lib/snmp/doc/src/snmp_app.xml index 694e619da1..f6abe783b3 100644 --- a/lib/snmp/doc/src/snmp_app.xml +++ b/lib/snmp/doc/src/snmp_app.xml @@ -1,10 +1,10 @@ -<?xml version="1.0" encoding="latin1" ?> +<?xml version="1.0" encoding="iso-8859-1" ?> <!DOCTYPE appref SYSTEM "appref.dtd"> <appref> <header> <copyright> - <year>1997</year><year>2010</year> + <year>1997</year><year>2011</year> <holder>Ericsson AB. All Rights Reserved.</holder> </copyright> <legalnotice> @@ -78,7 +78,15 @@ ]. </pre> - <!-- The info below is also found in the snmp_config.xml file --> + + <!-- + ******************************************************** + + The info below is also found in the snmp_config.xml file + + ******************************************************** + --> + <p>Each snmp component has its own set of configuration parameters, even though some of the types are common to both components. </p> @@ -92,6 +100,7 @@ {agent_verbosity, verbosity()} | {discovery, agent_discovery()} | {versions, versions()} | + {gb_max_vbs, gb_max_vbs()} | {priority, priority()} | {multi_threaded, multi_threaded()} | {db_dir, db_dir()} | @@ -122,8 +131,10 @@ {def_user_data, def_user_data()} </pre> + <marker id="agent_opts_and_types"></marker> <p>Agent specific config options and types:</p> <taglist> + <marker id="agent_type"></marker> <tag><c><![CDATA[agent_type() = master | sub <optional>]]></c></tag> <item> <p>If <c>master</c>, one master agent is @@ -131,6 +142,7 @@ <p>Default is <c>master</c>.</p> </item> + <marker id="agent_disco"></marker> <tag><c><![CDATA[agent_discovery() = [agent_discovery_opt()] <optional>]]></c></tag> <item> <p><c>agent_discovery_opt() = @@ -143,6 +155,7 @@ <p>For defaults see the options in <c>agent_discovery_opt()</c>.</p> </item> + <marker id="agent_term_disco_opts"></marker> <tag><c><![CDATA[agent_terminating_discovery_opts() = [agent_terminating_discovery_opt()] <optional>]]></c></tag> <item> <p><c>agent_terminating_discovery_opt() = @@ -160,6 +173,7 @@ </list> </item> + <marker id="agent_orig_disco_opts"></marker> <tag><c><![CDATA[agent_originating_discovery_opts() = [agent_originating_discovery_opt()] <optional>]]></c></tag> <item> <p><c>agent_originating_discovery_opt() = @@ -173,6 +187,7 @@ </list> </item> + <marker id="agent_mt"></marker> <tag><c><![CDATA[multi_threaded() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c>, the agent is multi-threaded, with one @@ -180,11 +195,21 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="agent_data_dir"></marker> <tag><c><![CDATA[db_dir() = string() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP agent internal db files are stored.</p> </item> + <marker id="agent_gb_max_vbs"></marker> + <tag><c><![CDATA[gb_max_vbs() = pos_integer() | infinity <optional>]]></c></tag> + <item> + <p>Defines the maximum number of varbinds allowed + in a Get-BULK response.</p> + <p>Default is <c>1000</c>.</p> + </item> + + <marker id="agent_local_db"></marker> <tag><c><![CDATA[local_db() = [local_db_opt()] <optional>]]></c></tag> <item> <p><c>local_db_opt() = {repair, agent_repair()} | {auto_save, agent_auto_save()} | {verbosity, verbosity()}</c></p> @@ -192,6 +217,7 @@ <p>For defaults see the options in <c>local_db_opt()</c>.</p> </item> + <marker id="agent_ldb_repair"></marker> <tag><c><![CDATA[agent_repair() = false | true | force <optional>]]></c></tag> <item> <p>When starting snmpa_local_db it always tries to open an @@ -202,6 +228,7 @@ <p>Default is <c>true</c>.</p> </item> + <marker id="agent_ldb_auto_save"></marker> <tag><c><![CDATA[agent_auto_save() = integer() | infinity <optional>]]></c></tag> <item> <p>The auto save interval. The table is flushed to disk @@ -209,6 +236,7 @@ <p>Default is <c>5000</c>.</p> </item> + <marker id="agent_net_if"></marker> <tag><c><![CDATA[agent_net_if() = [agent_net_if_opt()] <optional>]]></c></tag> <item> <p><c>agent_net_if_opt() = {module, agent_net_if_module()} | {verbosity, verbosity()} | {options, agent_net_if_options()}</c></p> @@ -217,6 +245,7 @@ <p>For defaults see the options in <c>agent_net_if_opt()</c>.</p> </item> + <marker id="agent_ni_module"></marker> <tag><c><![CDATA[agent_net_if_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface part for the @@ -225,6 +254,7 @@ <p>Default is <c>snmpa_net_if</c>.</p> </item> + <marker id="agent_ni_opts"></marker> <tag><c><![CDATA[agent_net_if_options() = [agent_net_if_option()] <optional>]]></c></tag> <item> <p><c>agent_net_if_option() = {bind_to, bind_to()} | @@ -239,12 +269,14 @@ <p>For defaults see the options in <c>agent_net_if_option()</c>.</p> </item> + <marker id="agent_ni_req_limit"></marker> <tag><c><![CDATA[req_limit() = integer() | infinity <optional>]]></c></tag> <item> <p>Max number of simultaneous requests handled by the agent.</p> <p>Default is <c>infinity</c>.</p> </item> + <marker id="agent_ni_filter_opts"></marker> <tag><c><![CDATA[agent_net_if_filter_options() = [agent_net_if_filter_option()] <optional>]]></c></tag> <item> <p><c>agent_net_if_filter_option() = {module, agent_net_if_filter_module()}</c></p> @@ -255,6 +287,7 @@ <c>agent_net_if_filter_option()</c>.</p> </item> + <marker id="agent_ni_filter_module"></marker> <tag><c><![CDATA[agent_net_if_filter_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface filter part for the @@ -263,6 +296,7 @@ <p>Default is <c>snmpa_net_if_filter</c>.</p> </item> + <marker id="agent_mibs"></marker> <tag><c><![CDATA[agent_mibs() = [string()] <optional>]]></c></tag> <item> <p>Specifies a list of MIBs (including path) that defines which MIBs @@ -277,6 +311,7 @@ <p>Default is <c>[]</c>.</p> </item> + <marker id="agent_mib_storage"></marker> <tag><c><![CDATA[mib_storage() = ets | {ets, Dir} | {ets, Dir, Action} | dets | {dets, Dir} | {dets, Dir, Action} | mnesia | {mnesia, Nodes} | {mnesia, Nodes, Action} <optional>]]></c></tag> <item> <p>Specifies how info retrieved from the mibs will be stored.</p> @@ -302,6 +337,7 @@ mnesia/dets table already exist.</p> </item> + <marker id="agent_mib_server"></marker> <tag><c><![CDATA[mib_server() = [mib_server_opt()] <optional>]]></c></tag> <item> <p><c>mib_server_opt() = {mibentry_override, mibentry_override()} | {trapentry_override, trapentry_override()} | {verbosity, verbosity()} | {cache, mibs_cache()}</c></p> @@ -309,6 +345,7 @@ <p>For defaults see the options in <c>mib_server_opt()</c>.</p> </item> + <marker id="agent_ms_meo"></marker> <tag><c><![CDATA[mibentry_override() = bool() <optional>]]></c></tag> <item> <p>If this value is false, then when loading a mib each mib- @@ -318,6 +355,7 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="agent_ms_teo"></marker> <tag><c><![CDATA[trapentry_override() = bool() <optional>]]></c></tag> <item> <p>If this value is false, then when loading a mib each trap @@ -327,6 +365,7 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="agent_ms_cache"></marker> <tag><c><![CDATA[mibs_cache() = bool() | mibs_cache_opts() <optional>]]></c></tag> <item> <p>Shall the agent utilize the mib server lookup cache or not.</p> @@ -334,6 +373,7 @@ default values apply).</p> </item> + <marker id="agent_ms_cache_opts"></marker> <tag><c><![CDATA[mibs_cache_opts() = [mibs_cache_opt()] <optional>]]></c></tag> <item> <p><c>mibs_cache_opt() = {autogc, mibs_cache_autogc()} | {gclimit, mibs_cache_gclimit()} | {age, mibs_cache_age()}</c></p> @@ -341,6 +381,7 @@ <p>For defaults see the options in <c>mibs_cache_opt()</c>.</p> </item> + <marker id="agent_ms_cache_autogc"></marker> <tag><c><![CDATA[mibs_cache_autogc() = bool() <optional>]]></c></tag> <item> <p>Defines if the mib server shall perform cache gc automatically or @@ -349,6 +390,7 @@ <p>Default is <c>true</c>.</p> </item> + <marker id="agent_ms_cache_age"></marker> <tag><c><![CDATA[mibs_cache_age() = integer() > 0 <optional>]]></c></tag> <item> <p>Defines how old the entries in the cache will be allowed before @@ -358,6 +400,7 @@ <p>Default is <c>10 timutes</c>.</p> </item> + <marker id="agent_ms_cache_gclimit"></marker> <tag><c><![CDATA[mibs_cache_gclimit() = integer() > 0 | infinity <optional>]]></c></tag> <item> <p>When performing a GC, this is the max number of cache entries @@ -368,6 +411,7 @@ <p>Default is <c>100</c>.</p> </item> + <marker id="agent_error_report_mod"></marker> <tag><c><![CDATA[error_report_mod() = atom() <optional>]]></c></tag> <item> <p>Defines an error report module, implementing the @@ -377,6 +421,7 @@ <p>Default is <c>snmpa_error_logger</c>.</p> </item> + <marker id="agent_symbolic_store"></marker> <tag><c>symbolic_store() = [symbolic_store_opt()]</c></tag> <item> <p><c>symbolic_store_opt() = {verbosity, verbosity()}</c></p> @@ -384,23 +429,29 @@ <p>For defaults see the options in <c>symbolic_store_opt()</c>.</p> </item> + <marker id="agent_target_cache"></marker> <tag><c>target_cache() = [target_cache_opt()]</c></tag> <item> <p><c>target_cache_opt() = {verbosity, verbosity()}</c></p> <p>Defines options specific for the SNMP agent target cache. </p> <p>For defaults see the options in <c>target_cache_opt()</c>.</p> </item> + + <marker id="agent_config"></marker> <tag><c><![CDATA[agent_config() = [agent_config_opt()] <mandatory>]]></c></tag> <item> <p><c>agent_config_opt() = {dir, agent_config_dir()} | {force_load, force_load()} | {verbosity, verbosity()}</c></p> <p>Defines specific config related options for the SNMP agent. </p> <p>For defaults see the options in <c>agent_config_opt()</c>.</p> </item> + + <marker id="agent_config_dir"></marker> <tag><c><![CDATA[agent_config_dir = dir() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP agent configuration files are stored.</p> </item> + <marker id="agent_force_load"></marker> <tag><c><![CDATA[force_load() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c> the configuration files are re-read @@ -412,14 +463,18 @@ </item> </taglist> + <marker id="manager_opts_and_types"></marker> <p>Manager specific config options and types:</p> <taglist> + <marker id="manager_server"></marker> <tag><c><![CDATA[server() = [server_opt()] <optional>]]></c></tag> <item> <p><c>server_opt() = {timeout, server_timeout()} | {verbosity, verbosity()}</c></p> <p>Specifies the options for the manager server process.</p> <p>Default is <c>silence</c>.</p> </item> + + <marker id="manager_server_timeout"></marker> <tag><c><![CDATA[server_timeout() = integer() <optional>]]></c></tag> <item> <p>Asynchroneous request cleanup time. For every requests, @@ -440,6 +495,7 @@ <p>Default is <c>30000</c>.</p> </item> + <marker id="manager_config"></marker> <tag><c><![CDATA[manager_config() = [manager_config_opt()] <mandatory>]]></c></tag> <item> <p><c>manager_config_opt() = {dir, manager_config_dir()} | {db_dir, manager_db_dir()} | {db_init_error, db_init_error()} | {repair, manager_repair()} | {auto_save, manager_auto_save()} | {verbosity, verbosity()}</c></p> @@ -447,16 +503,19 @@ <p>For defaults see the options in <c>manager_config_opt()</c>.</p> </item> + <marker id="manager_config_dir"></marker> <tag><c><![CDATA[manager_config_dir = dir() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP manager configuration files are stored.</p> </item> + <marker id="manager_config_db_dir"></marker> <tag><c><![CDATA[manager_db_dir = dir() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP manager store persistent data.</p> </item> + <marker id="manager_config_repair"></marker> <tag><c><![CDATA[manager_repair() = false | true | force <optional>]]></c></tag> <item> <p>Defines the repair option for the persistent database (if @@ -464,6 +523,7 @@ <p>Default is <c>true</c>.</p> </item> + <marker id="manager_config_auto_save"></marker> <tag><c><![CDATA[manager_auto_save() = integer() | infinity <optional>]]></c></tag> <item> <p>The auto save interval. The table is flushed to disk @@ -471,6 +531,7 @@ <p>Default is <c>5000</c>.</p> </item> + <marker id="manager_irb"></marker> <tag><c><![CDATA[manager_irb() = auto | user | {user, integer()} <optional>]]></c></tag> <item> <p>This option defines how the manager will handle the sending of @@ -500,6 +561,7 @@ <p>Default is <c>auto</c>.</p> </item> + <marker id="manager_mibs"></marker> <tag><c><![CDATA[manager_mibs() = [string()] <optional>]]></c></tag> <item> <p>Specifies a list of MIBs (including path) and defines which MIBs @@ -507,6 +569,7 @@ <p>Default is <c>[]</c>.</p> </item> + <marker id="manager_net_if"></marker> <tag><c><![CDATA[manager_net_if() = [manager_net_if_opt()] <optional>]]></c></tag> <item> <p><c>manager_net_if_opt() = {module, manager_net_if_module()} | @@ -517,6 +580,7 @@ <p>For defaults see the options in <c>manager_net_if_opt()</c>.</p> </item> + <marker id="manager_ni_opts"></marker> <tag><c><![CDATA[manager_net_if_options() = [manager_net_if_option()] <optional>]]></c></tag> <item> <p><c>manager_net_if_option() = {bind_to, bind_to()} | @@ -530,6 +594,7 @@ <p>For defaults see the options in <c>manager_net_if_option()</c>.</p> </item> + <marker id="manager_ni_module"></marker> <tag><c><![CDATA[manager_net_if_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface part for the @@ -538,6 +603,7 @@ <p>Default is <c>snmpm_net_if</c>.</p> </item> + <marker id="manager_ni_filter_opts"></marker> <tag><c><![CDATA[manager_net_if_filter_options() = [manager_net_if_filter_option()] <optional>]]></c></tag> <item> <p><c>manager_net_if_filter_option() = {module, manager_net_if_filter_module()}</c></p> @@ -548,6 +614,7 @@ <c>manager_net_if_filter_option()</c>.</p> </item> + <marker id="manager_ni_filter_module"></marker> <tag><c><![CDATA[manager_net_if_filter_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface filter part for the @@ -556,6 +623,7 @@ <p>Default is <c>snmpm_net_if_filter</c>.</p> </item> + <marker id="manager_def_user_module"></marker> <tag><c><![CDATA[def_user_module() = atom() <optional>]]></c></tag> <item> <p>The module implementing the default user. See the @@ -563,6 +631,7 @@ <p>Default is <c>snmpm_user_default</c>.</p> </item> + <marker id="manager_def_user_data"></marker> <tag><c><![CDATA[def_user_data() = term() <optional>]]></c></tag> <item> <p>Data for the default user. Passed to the user module when @@ -571,8 +640,10 @@ </item> </taglist> + <marker id="common_types"></marker> <p>Common config types:</p> <taglist> + <marker id="restart_type"></marker> <tag><c>restart_type() = permanent | transient | temporary</c></tag> <item> <p>See <seealso marker="stdlib:supervisor#child_spec">supervisor</seealso> @@ -580,6 +651,8 @@ <p>Default is <c>permanent</c> for the agent and <c>transient</c> for the manager.</p> </item> + + <marker id="db_init_error"></marker> <tag><c>db_init_error() = terminate | create</c></tag> <item> <p>Defines what to do if the agent or manager is unable to open an @@ -588,23 +661,31 @@ agent/manager will remove the faulty file(s) and create new ones.</p> <p>Default is <c>terminate</c>.</p> </item> + + <marker id="prio"></marker> <tag><c><![CDATA[priority() = atom() <optional>]]></c></tag> <item> <p>Defines the Erlang priority for all SNMP processes.</p> <p>Default is <c>normal</c>.</p> </item> + + <marker id="versions"></marker> <tag><c><![CDATA[versions() = [version()] <optional>]]></c></tag> <item> <p><c>version() = v1 | v2 | v3</c></p> <p>Which SNMP versions shall be accepted/used.</p> <p>Default is <c>[v1,v2,v3]</c>.</p> </item> + + <marker id="verbosity"></marker> <tag><c><![CDATA[verbosity() = silence | info | log | debug | trace <optional>]]></c></tag> <item> <p>Verbosity for a SNMP process. This specifies now much debug info is printed.</p> <p>Default is <c>silence</c>.</p> </item> + + <marker id="bind_to"></marker> <tag><c><![CDATA[bind_to() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c>, net_if binds to the IP address. @@ -612,6 +693,8 @@ where it is running. </p> <p>Default is <c>false</c>.</p> </item> + + <marker id="no_reuse"></marker> <tag><c><![CDATA[no_reuse() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c>, net_if does not specify that the IP @@ -619,22 +702,30 @@ the address is set to reusable. </p> <p>Default is <c>false</c>.</p> </item> + + <marker id="recbuf"></marker> <tag><c><![CDATA[recbuf() = integer() <optional>]]></c></tag> <item> <p>Receive buffer size. </p> <p>Default value is defined by <c>gen_udp</c>.</p> </item> + + <marker id="sndbuf"></marker> <tag><c><![CDATA[sndbuf() = integer() <optional>]]></c></tag> <item> <p>Send buffer size. </p> <p>Default value is defined by <c>gen_udp</c>.</p> </item> + + <marker id="note_store"></marker> <tag><c><![CDATA[note_store() = [note_store_opt()] <optional>]]></c></tag> <item> <p><c>note_store_opt() = {timeout, note_store_timeout()} | {verbosity, verbosity()}</c></p> <p>Specifies the start-up verbosity for the SNMP note store.</p> <p>For defaults see the options in <c>note_store_opt()</c>.</p> </item> + + <marker id="ns_timeout"></marker> <tag><c><![CDATA[note_store_timeout() = integer() <optional>]]></c></tag> <item> <p>Note cleanup time. When storing a note in the note store, @@ -643,9 +734,9 @@ milli-seconds.</p> <p>Default is <c>30000</c>.</p> - <marker id="audit_trail_log"></marker> </item> + <marker id="audit_trail_log"></marker> <tag><c><![CDATA[audit_trail_log() = [audit_trail_log_opt()] <optional>]]></c></tag> <item> <p><c>audit_trail_log_opt() = {type, atl_type()} | {dir, atl_dir()} | {size, atl_size()} | {repair, atl_repair()} | {seqno, atl_seqno()}</c></p> @@ -655,6 +746,8 @@ <c>size</c> options are mandatory.</p> <p>If not present, audit trail logging is not used.</p> </item> + + <marker id="atl_type"></marker> <tag><c><![CDATA[atl_type() = read | write | read_write <optional>]]></c></tag> <item> <p>Specifies what type of an audit trail log should be used. @@ -675,12 +768,16 @@ </list> <p>Default is <c>read_write</c>.</p> </item> + + <marker id="atl_dir"></marker> <tag><c><![CDATA[atl_dir = dir() <mandatory>]]></c></tag> <item> <p>Specifies where the audit trail log should be stored.</p> <p>If <c>audit_trail_log</c> specifies that logging should take place, this parameter <em>must</em> be defined.</p> </item> + + <marker id="atl_size"></marker> <tag><c><![CDATA[atl_size() = {integer(), integer()} <mandatory>]]></c></tag> <item> <p>Specifies the size of the audit @@ -688,6 +785,8 @@ <p>If <c>audit_trail_log</c> specifies that logging should take place, this parameter <em>must</em> be defined.</p> </item> + + <marker id="atl_repair"></marker> <tag><c><![CDATA[atl_repair() = true | false | truncate | snmp_repair <optional>]]></c></tag> <item> <p>Specifies if and how the audit trail log shall be repaired @@ -699,6 +798,8 @@ analysis.</p> <p>Default is <c>true</c>.</p> </item> + + <marker id="atl_seqno"></marker> <tag><c><![CDATA[atl_seqno() = true | false <optional>]]></c></tag> <item> <p>Specifies if the audit trail log entries will be (sequence) diff --git a/lib/snmp/doc/src/snmp_config.xml b/lib/snmp/doc/src/snmp_config.xml index fc8562b638..0a49b7a62e 100644 --- a/lib/snmp/doc/src/snmp_config.xml +++ b/lib/snmp/doc/src/snmp_config.xml @@ -40,6 +40,7 @@ <item>starting the application (agent and/or manager)</item> <item>debugging the application (agent and/or manager)</item> </list> + <p>Refer also to the chapter(s) <seealso marker="snmp_agent_config_files">Definition of Agent Configuration Files</seealso> and <seealso marker="snmp_manager_config_files">Definition of Manager Configuration Files</seealso> which contains more detailed information @@ -73,7 +74,14 @@ </item> </list> - <!-- The info below is also found in the snmp_app.xml file --> + + <!-- + ***************************************************** + + The info below is also found in the snmp_app.xml file + + ***************************************************** + --> <p>The agent and manager uses (application) configuration parameters to find out where these directories are located. The parameters should be @@ -87,6 +95,7 @@ {agent_verbosity, verbosity()} | {versions, versions()} | {discovery, agent_discovery()} | + {gb_max_vbs, gb_max_vbs()} | {priority, priority()} | {multi_threaded, multi_threaded()} | {db_dir, db_dir()} | @@ -117,8 +126,10 @@ {def_user_data, def_user_data()} </pre> + <marker id="agent_opts_and_types"></marker> <p>Agent specific config options and types:</p> <taglist> + <marker id="agent_type"></marker> <tag><c><![CDATA[agent_type() = master | sub <optional>]]></c></tag> <item> <p>If <c>master</c>, one master agent is @@ -126,6 +137,7 @@ <p>Default is <c>master</c>.</p> </item> + <marker id="agent_disco"></marker> <tag><c><![CDATA[agent_discovery() = [agent_discovery_opt()] <optional>]]></c></tag> <item> <p><c>agent_discovery_opt() = @@ -138,6 +150,7 @@ <p>For defaults see the options in <c>agent_discovery_opt()</c>.</p> </item> + <marker id="agent_term_disco_opts"></marker> <tag><c><![CDATA[agent_terminating_discovery_opts() = [agent_terminating_discovery_opt()] <optional>]]></c></tag> <item> <p><c>agent_terminating_discovery_opt() = @@ -155,6 +168,7 @@ </list> </item> + <marker id="agent_orig_disco_opts"></marker> <tag><c><![CDATA[agent_originating_discovery_opts() = [agent_originating_discovery_opt()] <optional>]]></c></tag> <item> <p><c>agent_originating_discovery_opt() = @@ -168,6 +182,7 @@ </list> </item> + <marker id="agent_mt"></marker> <tag><c><![CDATA[multi_threaded() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c>, the agent is multi-threaded, with one @@ -175,11 +190,21 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="agent_data_dir"></marker> <tag><c><![CDATA[db_dir() = string() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP agent internal db files are stored.</p> </item> + <marker id="agent_gb_max_vbs"></marker> + <tag><c><![CDATA[gb_max_vbs() = pos_integer() | infinity <optional>]]></c></tag> + <item> + <p>Defines the maximum number of varbinds allowed + in a Get-BULK response.</p> + <p>Default is <c>1000</c>.</p> + </item> + + <marker id="agent_local_db"></marker> <tag><c><![CDATA[local_db() = [local_db_opt()] <optional>]]></c></tag> <item> <p><c>local_db_opt() = {repair, agent_repair()} | {auto_save, agent_auto_save()} | {verbosity, verbosity()}</c></p> @@ -187,6 +212,7 @@ <p>For defaults see the options in <c>local_db_opt()</c>.</p> </item> + <marker id="agent_ldb_repair"></marker> <tag><c><![CDATA[agent_repair() = false | true | force <optional>]]></c></tag> <item> <p>When starting snmpa_local_db it always tries to open an @@ -197,6 +223,7 @@ <p>Default is <c>true</c>.</p> </item> + <marker id="agent_ldb_auto_save"></marker> <tag><c><![CDATA[agent_auto_save() = integer() | infinity <optional>]]></c></tag> <item> <p>The auto save interval. The table is flushed to disk @@ -204,6 +231,7 @@ <p>Default is <c>5000</c>.</p> </item> + <marker id="agent_net_if"></marker> <tag><c><![CDATA[agent_net_if() = [agent_net_if_opt()] <optional>]]></c></tag> <item> <p><c>agent_net_if_option() = {module, agent_net_if_module()} | @@ -214,6 +242,7 @@ <p>For defaults see the options in <c>agent_net_if_opt()</c>.</p> </item> + <marker id="agent_ni_module"></marker> <tag><c><![CDATA[agent_net_if_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface part for the @@ -222,6 +251,7 @@ <p>Default is <c>snmpa_net_if</c>.</p> </item> + <marker id="agent_ni_opts"></marker> <tag><c><![CDATA[agent_net_if_options() = [agent_net_if_option()] <optional>]]></c></tag> <item> <p><c>agent_net_if_option() = {bind_to, bind_to()} | @@ -236,6 +266,14 @@ <p>For defaults see the options in <c>agent_net_if_option()</c>.</p> </item> + <marker id="agent_ni_req_limit"></marker> + <tag><c><![CDATA[req_limit() = integer() | infinity <optional>]]></c></tag> + <item> + <p>Max number of simultaneous requests handled by the agent.</p> + <p>Default is <c>infinity</c>.</p> + </item> + + <marker id="agent_ni_filter_opts"></marker> <tag><c><![CDATA[agent_net_if_filter_options() = [agent_net_if_filter_option()] <optional>]]></c></tag> <item> <p><c><![CDATA[agent_net_if_filter_option() = {module, agent_net_if_filter_module()}]]></c></p> @@ -245,6 +283,7 @@ <p>For defaults see the options in <c>agent_net_if_filter_option()</c>.</p> </item> + <marker id="agent_ni_filter_module"></marker> <tag><c><![CDATA[agent_net_if_filter_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface filter part for the @@ -254,12 +293,7 @@ <p>Default is <c>snmpa_net_if_filter</c>.</p> </item> - <tag><c><![CDATA[req_limit() = integer() | infinity <optional>]]></c></tag> - <item> - <p>Max number of simultaneous requests handled by the agent.</p> - <p>Default is <c>infinity</c>.</p> - </item> - + <marker id="agent_mibs"></marker> <tag><c><![CDATA[agent_mibs() = [string()] <optional>]]></c></tag> <item> <p>Specifies a list of MIBs (including path) that defines which MIBs @@ -274,6 +308,7 @@ <p>Default is <c>[]</c>.</p> </item> + <marker id="agent_mib_storage"></marker> <tag><c><![CDATA[mib_storage() = ets | {ets, Dir} | {ets, Dir, Action} | dets | {dets, Dir} | {dets, Dir, Action} | mnesia | {mnesia, Nodes} | {mnesia, Nodes, Action} <optional>]]></c></tag> <item> <p>Specifies how info retrieved from the mibs will be stored.</p> @@ -299,6 +334,7 @@ mnesia/dets table already exist.</p> </item> + <marker id="agent_mib_server"></marker> <tag><c><![CDATA[mib_server() = [mib_server_opt()] <optional>]]></c></tag> <item> <p><c>mib_server_opt() = {mibentry_override, mibentry_override()} | {trapentry_override, trapentry_override()} | {verbosity, verbosity()} | {cache, mibs_cache()}</c></p> @@ -306,6 +342,7 @@ <p>For defaults see the options in <c>mib_server_opt()</c>.</p> </item> + <marker id="agent_ms_meo"></marker> <tag><c><![CDATA[mibentry_override() = bool() <optional>]]></c></tag> <item> <p>If this value is false, then when loading a mib each mib- @@ -315,6 +352,7 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="agent_ms_teo"></marker> <tag><c><![CDATA[trapentry_override() = bool() <optional>]]></c></tag> <item> <p>If this value is false, then when loading a mib each trap @@ -324,6 +362,7 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="agent_ms_cache"></marker> <tag><c><![CDATA[mibs_cache() = bool() | mibs_cache_opts() <optional>]]></c></tag> <item> <p>Shall the agent utilize the mib server lookup cache or not.</p> @@ -331,6 +370,7 @@ default values apply).</p> </item> + <marker id="agent_ms_cache_opts"></marker> <tag><c><![CDATA[mibs_cache_opts() = [mibs_cache_opt()] <optional>]]></c></tag> <item> <p><c>mibs_cache_opt() = {autogc, mibs_cache_autogc()} | {gclimit, mibs_cache_gclimit()} | {age, mibs_cache_age()}</c></p> @@ -338,6 +378,7 @@ <p>For defaults see the options in <c>mibs_cache_opt()</c>.</p> </item> + <marker id="agent_ms_cache_autogc"></marker> <tag><c><![CDATA[mibs_cache_autogc() = bool() <optional>]]></c></tag> <item> <p>Defines if the mib server shall perform cache gc automatically or @@ -346,6 +387,7 @@ <p>Default is <c>true</c>.</p> </item> + <marker id="agent_ms_cache_age"></marker> <tag><c><![CDATA[mibs_cache_age() = integer() > 0 <optional>]]></c></tag> <item> <p>Defines how old the entries in the cache will be allowed before @@ -355,6 +397,7 @@ <p>Default is <c>10 timutes</c>.</p> </item> + <marker id="agent_ms_cache_gclimit"></marker> <tag><c><![CDATA[mibs_cache_gclimit() = integer() > 0 | infinity <optional>]]></c></tag> <item> <p>When performing a GC, this is the max number of cache entries @@ -365,6 +408,7 @@ <p>Default is <c>100</c>.</p> </item> + <marker id="agent_error_report_mod"></marker> <tag><c><![CDATA[error_report_mod() = atom() <optional>]]></c></tag> <item> <p>Defines an error report module, implementing the @@ -374,6 +418,7 @@ <p>Default is <c>snmpa_error_logger</c>.</p> </item> + <marker id="agent_symbolic_store"></marker> <tag><c>symbolic_store() = [symbolic_store_opt()]</c></tag> <item> <p><c>symbolic_store_opt() = {verbosity, verbosity()}</c></p> @@ -381,12 +426,15 @@ <p>For defaults see the options in <c>symbolic_store_opt()</c>.</p> </item> + <marker id="agent_target_cache"></marker> <tag><c>target_cache() = [target_cache_opt()]</c></tag> <item> <p><c>target_cache_opt() = {verbosity, verbosity()}</c></p> <p>Defines options specific for the SNMP agent target cache. </p> <p>For defaults see the options in <c>target_cache_opt()</c>.</p> </item> + + <marker id="agent_config"></marker> <tag><c><![CDATA[agent_config() = [agent_config_opt()] <mandatory>]]></c></tag> <item> <p><c>agent_config_opt() = {dir, agent_config_dir()} | {force_load, force_load()} | {verbosity, verbosity()}</c></p> @@ -394,11 +442,13 @@ <p>For defaults see the options in <c>agent_config_opt()</c>.</p> </item> + <marker id="agent_config_dir"></marker> <tag><c><![CDATA[agent_config_dir = dir() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP agent configuration files are stored.</p> </item> + <marker id="agent_force_load"></marker> <tag><c><![CDATA[force_load() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c> the configuration files are re-read @@ -410,14 +460,18 @@ </item> </taglist> + <marker id="manager_opts_and_types"></marker> <p>Manager specific config options and types:</p> <taglist> + <marker id="manager_server"></marker> <tag><c><![CDATA[server() = [server_opt()] <optional>]]></c></tag> <item> <p><c>server_opt() = {timeout, server_timeout()} | {verbosity, verbosity()}</c></p> <p>Specifies the options for the manager server process.</p> <p>Default is <c>silence</c>.</p> </item> + + <marker id="manager_server_timeout"></marker> <tag><c><![CDATA[server_timeout() = integer() <optional>]]></c></tag> <item> <p>Asynchroneous request cleanup time. For every requests, @@ -438,6 +492,7 @@ <p>Default is <c>30000</c>.</p> </item> + <marker id="manager_config"></marker> <tag><c><![CDATA[manager_config() = [manager_config_opt()] <mandatory>]]></c></tag> <item> <p><c>manager_config_opt() = {dir, manager_config_dir()} | {db_dir, manager_db_dir()} | {db_init_error, db_init_error()} | {repair, manager_repair()} | {auto_save, manager_auto_save()} | {verbosity, verbosity()}</c></p> @@ -445,16 +500,19 @@ <p>For defaults see the options in <c>manager_config_opt()</c>.</p> </item> + <marker id="manager_config_dir"></marker> <tag><c><![CDATA[manager_config_dir = dir() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP manager configuration files are stored.</p> </item> + <marker id="manager_config_db_dir"></marker> <tag><c><![CDATA[manager_db_dir = dir() <mandatory>]]></c></tag> <item> <p>Defines where the SNMP manager store persistent data.</p> </item> + <marker id="manager_config_repair"></marker> <tag><c><![CDATA[manager_repair() = false | true | force <optional>]]></c></tag> <item> <p>Defines the repair option for the persistent database (if @@ -462,6 +520,7 @@ <p>Default is <c>true</c>.</p> </item> + <marker id="manager_config_auto_save"></marker> <tag><c><![CDATA[manager_auto_save() = integer() | infinity <optional>]]></c></tag> <item> <p>The auto save interval. The table is flushed to disk @@ -469,6 +528,7 @@ <p>Default is <c>5000</c>.</p> </item> + <marker id="manager_irb"></marker> <tag><c><![CDATA[manager_irb() = auto | user | {user, integer()} <optional>]]></c></tag> <item> <p>This option defines how the manager will handle the sending of @@ -498,6 +558,7 @@ <p>Default is <c>auto</c>.</p> </item> + <marker id="manager_mibs"></marker> <tag><c><![CDATA[manager_mibs() = [string()] <optional>]]></c></tag> <item> <p>Specifies a list of MIBs (including path) and defines which MIBs @@ -505,6 +566,7 @@ <p>Default is <c>[]</c>.</p> </item> + <marker id="manager_net_if"></marker> <tag><c><![CDATA[manager_net_if() = [manager_net_if_opt()] <optional>]]></c></tag> <item> <p><c>manager_net_if_opt() = {module, manager_net_if_module()} | @@ -515,6 +577,7 @@ <p>For defaults see the options in <c>manager_net_if_opt()</c>.</p> </item> + <marker id="manager_ni_opts"></marker> <tag><c><![CDATA[manager_net_if_options() = [manager_net_if_option()] <optional>]]></c></tag> <item> <p><c>manager_net_if_option() = {bind_to, bind_to()} | @@ -528,6 +591,7 @@ <p>For defaults see the options in <c>manager_net_if_option()</c>.</p> </item> + <marker id="manager_ni_module"></marker> <tag><c><![CDATA[manager_net_if_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface part for the @@ -536,6 +600,7 @@ <p>Default is <c>snmpm_net_if</c>.</p> </item> + <marker id="manager_ni_filter_opts"></marker> <tag><c><![CDATA[manager_net_if_filter_options() = [manager_net_if_filter_option()] <optional>]]></c></tag> <item> <p><c>manager_net_if_filter_option() = {module, manager_net_if_filter_module()}</c></p> @@ -546,6 +611,7 @@ <c>manager_net_if_filter_option()</c>.</p> </item> + <marker id="manager_ni_filter_module"></marker> <tag><c><![CDATA[manager_net_if_filter_module() = atom() <optional>]]></c></tag> <item> <p>Module which handles the network interface filter part for the @@ -554,6 +620,7 @@ <p>Default is <c>snmpm_net_if_filter</c>.</p> </item> + <marker id="manager_def_user_module"></marker> <tag><c><![CDATA[def_user_module() = atom() <optional>]]></c></tag> <item> <p>The module implementing the default user. See the @@ -561,6 +628,7 @@ <p>Default is <c>snmpm_user_default</c>.</p> </item> + <marker id="manager_def_user_data"></marker> <tag><c><![CDATA[def_user_data() = term() <optional>]]></c></tag> <item> <p>Data for the default user. Passed to the user when calling @@ -569,8 +637,10 @@ </item> </taglist> + <marker id="common_types"></marker> <p>Common config types:</p> <taglist> + <marker id="restart_type"></marker> <tag><c>restart_type() = permanent | transient | temporary</c></tag> <item> <p>See <seealso marker="stdlib:supervisor#child_spec">supervisor</seealso> @@ -579,6 +649,7 @@ for the manager.</p> </item> + <marker id="db_init_error"></marker> <tag><c>db_init_error() = terminate | create</c></tag> <item> <p>Defines what to do if the agent is unable to open an @@ -588,12 +659,14 @@ <p>Default is <c>terminate</c>.</p> </item> + <marker id="prio"></marker> <tag><c><![CDATA[priority() = atom() <optional>]]></c></tag> <item> <p>Defines the Erlang priority for all SNMP processes.</p> <p>Default is <c>normal</c>.</p> </item> + <marker id="versions"></marker> <tag><c><![CDATA[versions() = [version()] <optional>]]></c></tag> <item> <p><c>version() = v1 | v2 | v3</c></p> @@ -601,6 +674,7 @@ <p>Default is <c>[v1,v2,v3]</c>.</p> </item> + <marker id="verbosity"></marker> <tag><c><![CDATA[verbosity() = silence | info | log | debug | trace <optional>]]></c></tag> <item> <p>Verbosity for a SNMP process. This specifies now much debug info @@ -608,6 +682,7 @@ <p>Default is <c>silence</c>.</p> </item> + <marker id="bind_to"></marker> <tag><c><![CDATA[bind_to() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c>, net_if binds to the IP address. @@ -616,6 +691,7 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="no_reuse"></marker> <tag><c><![CDATA[no_reuse() = bool() <optional>]]></c></tag> <item> <p>If <c>true</c>, net_if does not specify that the IP @@ -624,17 +700,21 @@ <p>Default is <c>false</c>.</p> </item> + <marker id="recbuf"></marker> <tag><c><![CDATA[recbuf() = integer() <optional>]]></c></tag> <item> <p>Receive buffer size. </p> <p>Default value is defined by <c>gen_udp</c>.</p> </item> + + <marker id="sndbuf"></marker> <tag><c><![CDATA[sndbuf() = integer() <optional>]]></c></tag> <item> <p>Send buffer size. </p> <p>Default value is defined by <c>gen_udp</c>.</p> </item> + <marker id="note_store"></marker> <tag><c><![CDATA[note_store() = [note_store_opt()] <optional>]]></c></tag> <item> <p><c>note_store_opt() = {timeout, note_store_timeout()} | {verbosity, verbosity()}</c></p> @@ -642,6 +722,7 @@ <p>For defaults see the options in <c>note_store_opt()</c>.</p> </item> + <marker id="ns_timeout"></marker> <tag><c><![CDATA[note_store_timeout() = integer() <optional>]]></c></tag> <item> <p>Note cleanup time. When storing a note in the note store, @@ -649,10 +730,9 @@ process performs a GC to remove the expired note's. Time in milli-seconds.</p> <p>Default is <c>30000</c>.</p> - - <marker id="audit_trail_log"></marker> </item> + <marker id="audit_trail_log"></marker> <tag><c><![CDATA[audit_trail_log() [audit_trail_log_opt()] <optional>]]></c></tag> <item> <p><c>audit_trail_log_opt() = {type, atl_type()} | {dir, atl_dir()} | {size, atl_size()} | {repair, atl_repair()} | {seqno, atl_seqno()}</c></p> @@ -663,6 +743,7 @@ <p>If not present, audit trail logging is not used.</p> </item> + <marker id="atl_type"></marker> <tag><c><![CDATA[atl_type() = read | write | read_write <optional>]]></c></tag> <item> <p>Specifies what type of an audit trail log should be used. @@ -684,6 +765,7 @@ <p>Default is <c>read_write</c>.</p> </item> + <marker id="atl_dir"></marker> <tag><c><![CDATA[atl_dir = dir() <mandatory>]]></c></tag> <item> <p>Specifies where the audit trail log should be stored.</p> @@ -691,6 +773,7 @@ place, this parameter <em>must</em> be defined.</p> </item> + <marker id="atl_size"></marker> <tag><c><![CDATA[atl_size() = {integer(), integer()} <mandatory>]]></c></tag> <item> <p>Specifies the size of the audit @@ -699,6 +782,7 @@ take place, this parameter <em>must</em> be defined.</p> </item> + <marker id="atl_repair"></marker> <tag><c><![CDATA[atl_repair() = true | false | truncate | snmp_repair <optional>]]></c></tag> <item> <p>Specifies if and how the audit trail log shall be repaired @@ -710,6 +794,8 @@ analysis.</p> <p>Default is <c>true</c>.</p> </item> + + <marker id="atl_seqno"></marker> <tag><c><![CDATA[atl_seqno() = true | false <optional>]]></c></tag> <item> <p>Specifies if the audit trail log entries will be (sequence) |