diff options
author | Erlang/OTP <[email protected]> | 2009-11-20 14:54:40 +0000 |
---|---|---|
committer | Erlang/OTP <[email protected]> | 2009-11-20 14:54:40 +0000 |
commit | 84adefa331c4159d432d22840663c38f155cd4c1 (patch) | |
tree | bff9a9c66adda4df2106dfd0e5c053ab182a12bd /lib/snmp/test/test-mibs/RFC1271-MIB.mib | |
download | otp-84adefa331c4159d432d22840663c38f155cd4c1.tar.gz otp-84adefa331c4159d432d22840663c38f155cd4c1.tar.bz2 otp-84adefa331c4159d432d22840663c38f155cd4c1.zip |
The R13B03 release.OTP_R13B03
Diffstat (limited to 'lib/snmp/test/test-mibs/RFC1271-MIB.mib')
-rw-r--r-- | lib/snmp/test/test-mibs/RFC1271-MIB.mib | 3492 |
1 files changed, 3492 insertions, 0 deletions
diff --git a/lib/snmp/test/test-mibs/RFC1271-MIB.mib b/lib/snmp/test/test-mibs/RFC1271-MIB.mib new file mode 100644 index 0000000000..25778dede8 --- /dev/null +++ b/lib/snmp/test/test-mibs/RFC1271-MIB.mib @@ -0,0 +1,3492 @@ + RFC1271-MIB DEFINITIONS ::= BEGIN + + IMPORTS + Counter FROM RFC1155-SMI + mib-2,DisplayString FROM RFC1213-MIB + OBJECT-TYPE FROM RFC-1212; + + -- This MIB module uses the extended OBJECT-TYPE macro as + -- defined in [9]. + + + -- Remote Network Monitoring MIB + + rmon OBJECT IDENTIFIER ::= { mib-2 16 } + + + -- textual conventions + + OwnerString ::= DisplayString + -- This data type is used to model an administratively + -- assigned name of the owner of a resource. This + -- information is taken from the NVT ASCII character set. + -- It is suggested that this name contain one or more + -- of the following: + -- IP address, management station name, network manager's + -- name, location, or phone number. + -- In some cases the agent itself will be the owner of + -- an entry. In these cases, this string shall be set + -- to a string starting with 'monitor'. + + + -- + -- SNMP access control is articulated entirely in terms of + -- the contents of MIB views; access to a particular SNMP + -- object instance depends only upon its presence or + -- absence in a particular MIB view and never upon its + -- value or the value of related object instances. Thus, + -- objects of this type afford resolution of resource + -- contention only among cooperating managers; they + -- realize no access control function with respect + -- to uncooperative parties. + -- + -- By convention, objects with this syntax are declared + -- as having + -- + -- SIZE (0..127) + + + EntryStatus ::= INTEGER + { valid(1), + createRequest(2), + underCreation(3), + invalid(4) + } + + -- The status of a table entry. + -- + -- Setting this object to the value invalid(4) has the + -- effect of invalidating the corresponding entry. + -- That is, it effectively disassociates the mapping + -- identified with said entry. + -- It is an implementation-specific matter as to whether + -- the agent removes an invalidated entry from the table. + -- Accordingly, management stations must be prepared to + -- receive tabular information from agents that corresponds + -- to entries currently not in use. Proper + -- interpretation of such entries requires examination + -- of the relevant EntryStatus object. + -- + -- An existing instance of this object cannot be set to + -- createRequest(2). This object may only be set to + -- createRequest(2) when this instance is created. When + -- this object is created, the agent may wish to create + -- supplemental object instances to complete a conceptual + -- row in this table. Immediately after completing the + -- create operation, the agent must set this object to + -- underCreation(3). + -- + -- Entries shall exist in the underCreation(3) state until + + + -- the management station is finished configuring the + -- entry and sets this object to valid(1) or aborts, + -- setting this object to invalid(4). If the agent + -- determines that an entry has been in the + -- underCreation(3) state for an abnormally long time, + -- it may decide that the management station has + -- crashed. If the agent makes this decision, + -- it may set this object to invalid(4) to reclaim the + -- entry. A prudent agent will understand that the + -- management station may need to wait for human input + -- and will allow for that possibility in its + -- determination of this abnormally long period. + + + statistics OBJECT IDENTIFIER ::= { rmon 1 } + history OBJECT IDENTIFIER ::= { rmon 2 } + alarm OBJECT IDENTIFIER ::= { rmon 3 } + hosts OBJECT IDENTIFIER ::= { rmon 4 } + hostTopN OBJECT IDENTIFIER ::= { rmon 5 } + matrix OBJECT IDENTIFIER ::= { rmon 6 } + filter OBJECT IDENTIFIER ::= { rmon 7 } + capture OBJECT IDENTIFIER ::= { rmon 8 } + event OBJECT IDENTIFIER ::= { rmon 9 } + + + -- The Statistics Group + -- + -- Implementation of the Statistics group is optional. + -- + -- The statistics group contains statistics measured by the + -- probe for each monitored interface on this device. These + -- statistics take the form of free running counters that + -- start from zero when a valid entry is created. + -- + -- This group currently has statistics defined only for + -- Ethernet interfaces. Each etherStatsEntry contains + -- statistics for one Ethernet interface. The probe must + -- create one etherStats entry for each monitored Ethernet + -- interface on the device. + + etherStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF EtherStatsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Ethernet statistics entries." + ::= { statistics 1 } + + + + etherStatsEntry OBJECT-TYPE + SYNTAX EtherStatsEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A collection of statistics kept for a particular + Ethernet interface." + INDEX { etherStatsIndex } + ::= { etherStatsTable 1 } + + EtherStatsEntry ::= SEQUENCE { + etherStatsIndex INTEGER (1..65535), + etherStatsDataSource OBJECT IDENTIFIER, + etherStatsDropEvents Counter, + etherStatsOctets Counter, + etherStatsPkts Counter, + etherStatsBroadcastPkts Counter, + etherStatsMulticastPkts Counter, + etherStatsCRCAlignErrors Counter, + etherStatsUndersizePkts Counter, + etherStatsOversizePkts Counter, + etherStatsFragments Counter, + etherStatsJabbers Counter, + etherStatsCollisions Counter, + etherStatsPkts64Octets Counter, + etherStatsPkts65to127Octets Counter, + etherStatsPkts128to255Octets Counter, + etherStatsPkts256to511Octets Counter, + etherStatsPkts512to1023Octets Counter, + etherStatsPkts1024to1518Octets Counter, + etherStatsOwner OwnerString, + etherStatsStatus INTEGER + } + + etherStatsIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of this object uniquely identifies this + etherStats entry." + ::= { etherStatsEntry 1 } + + etherStatsDataSource OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-write + STATUS mandatory + DESCRIPTION + + + "This object identifies the source of the data that + this etherStats entry is configured to analyze. This + source can be any ethernet interface on this device. + In order to identify a particular interface, this + object shall identify the instance of the ifIndex + object, defined in [4,6], for the desired interface. + For example, if an entry were to receive data from + interface #1, this object would be set to ifIndex.1. + + The statistics in this group reflect all packets + on the local network segment attached to the + identified interface. + + This object may not be modified if the associated + etherStatsStatus object is equal to valid(1)." + ::= { etherStatsEntry 2 } + + etherStatsDropEvents OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of events in which packets + were dropped by the probe due to lack of resources. + Note that this number is not necessarily the number of + packets dropped; it is just the number of times this + condition has been detected." + ::= { etherStatsEntry 3 } + + etherStatsOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of octets of data (including + those in bad packets) received on the + network (excluding framing bits but including + FCS octets)." + ::= { etherStatsEntry 4 } + + etherStatsPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error packets) + received." + ::= { etherStatsEntry 5 } + + + etherStatsBroadcastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of good packets received that were + directed to the broadcast address." + ::= { etherStatsEntry 6 } + + etherStatsMulticastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of good packets received that were + directed to a multicast address. Note that this + number does not include packets directed to the + broadcast address." + ::= { etherStatsEntry 7 } + + etherStatsCRCAlignErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets received that + had a length (excluding framing bits, but + including FCS octets) of between 64 and 1518 + octets, inclusive, but were not an integral number + of octets in length or had a bad Frame Check + Sequence (FCS)." + ::= { etherStatsEntry 8 } + + etherStatsUndersizePkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets received that were + less than 64 octets long (excluding framing bits, + but including FCS octets) and were otherwise well + formed." + ::= { etherStatsEntry 9 } + + etherStatsOversizePkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + + + DESCRIPTION + "The total number of packets received that were + longer than 1518 octets (excluding framing bits, + but including FCS octets) and were otherwise + well formed." + ::= { etherStatsEntry 10 } + + etherStatsFragments OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets received that were not an + integral number of octets in length or that had a bad + Frame Check Sequence (FCS), and were less than 64 + octets in length (excluding framing bits but + including FCS octets)." + ::= { etherStatsEntry 11 } + + etherStatsJabbers OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets received that were + longer than 1518 octets (excluding framing bits, + but including FCS octets), and were not an + integral number of octets in length or had + a bad Frame Check Sequence (FCS)." + ::= { etherStatsEntry 12 } + + etherStatsCollisions OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The best estimate of the total number of collisions + on this Ethernet segment." + ::= { etherStatsEntry 13 } + + etherStatsPkts64Octets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error + packets) received that were 64 octets in length + (excluding framing bits but including FCS octets)." + + + ::= { etherStatsEntry 14 } + + etherStatsPkts65to127Octets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error + packets) received that were between + 65 and 127 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { etherStatsEntry 15 } + + etherStatsPkts128to255Octets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error + packets) received that were between + 128 and 255 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { etherStatsEntry 16 } + + etherStatsPkts256to511Octets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error + packets) received that were between + 256 and 511 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { etherStatsEntry 17 } + + etherStatsPkts512to1023Octets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error + packets) received that were between + 512 and 1023 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { etherStatsEntry 18 } + + + + + + etherStatsPkts1024to1518Octets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets (including error + packets) received that were between + 1024 and 1518 octets in length inclusive + (excluding framing bits but including FCS octets)." + ::= { etherStatsEntry 19 } + + etherStatsOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is + therefore using the resources assigned to it." + ::= { etherStatsEntry 20 } + + etherStatsStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this etherStats entry." + ::= { etherStatsEntry 21 } + + + -- The History Group + + -- Implementation of the History group is optional. + -- + -- The history group records periodic statistical samples from + -- a network and stores them for later retrieval. The + -- historyControl table stores configuration entries that each + -- define an interface, polling period, and other parameters. + -- Once samples are taken, their data is stored in an entry + -- in a media-specific table. Each such entry defines one + -- sample, and is associated with the historyControlEntry that + -- caused the sample to be taken. Currently the only media- + -- specific table defined is the etherHistoryTable, for + -- Ethernet networks. + -- + -- If the probe keeps track of the time of day, it should + -- start the first sample of the history at a time such that + -- when the next hour of the day begins, a sample is + -- started at that instant. This tends to make more + + + -- user-friendly reports, and enables comparison of reports + -- from different probes that have relatively accurate time + -- of day. + -- + -- The monitor is encouraged to add two history control entries + -- per monitored interface upon initialization that describe + -- a short term and a long term polling period. Suggested + -- parameters are 30 seconds for the short term polling + -- period and 30 minutes for the long term period. + + historyControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF HistoryControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of history control entries." + ::= { history 1 } + + historyControlEntry OBJECT-TYPE + SYNTAX HistoryControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of parameters that set up a periodic + sampling of statistics." + INDEX { historyControlIndex } + ::= { historyControlTable 1 } + + HistoryControlEntry ::= SEQUENCE { + historyControlIndex INTEGER (1..65535), + historyControlDataSource OBJECT IDENTIFIER, + historyControlBucketsRequested INTEGER (1..65535), + historyControlBucketsGranted INTEGER (1..65535), + historyControlInterval INTEGER (1..3600), + historyControlOwner OwnerString, + historyControlStatus INTEGER + } + + historyControlIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in the + historyControl table. Each such entry defines a + set of samples at a particular interval for an + interface on the device." + ::= { historyControlEntry 1 } + + + historyControlDataSource OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object identifies the source of the data for + which historical data was collected and + placed in a media-specific table on behalf of this + historyControlEntry. This source can be any + interface on this device. In order to identify + a particular interface, this object shall identify + the instance of the ifIndex object, defined + in [4,6], for the desired interface. For example, + if an entry were to receive data from interface #1, + this object would be set to ifIndex.1. + + The statistics in this group reflect all packets + on the local network segment attached to the + identified interface. + + This object may not be modified if the associated + historyControlStatus object is equal to valid(1)." + ::= { historyControlEntry 2 } + + historyControlBucketsRequested OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The requested number of discrete time intervals + over which data is to be saved in the part of the + media-specific table associated with this + historyControl entry. + + When this object is created or modified, the probe + should set historyControlBucketsGranted as closely to + this object as is possible for the particular probe + implementation and available resources." + DEFVAL { 50 } + ::= { historyControlEntry 3 } + + historyControlBucketsGranted OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of discrete sampling intervals + over which data shall be saved in the part of + + + the media-specific table associated with this + historyControl entry. + + When the associated historyControlBucketsRequested + object is created or modified, the probe + should set this object as closely to the requested + value as is possible for the particular + probe implementation and available resources. The + probe must not lower this value except as a result + of a modification to the associated + historyControlBucketsRequested object. + + There will be times when the actual number of + buckets associated with this entry is less than + the value of this object. In this case, at the + end of each sampling interval, a new bucket will + be added to the media-specific table. + + When the number of buckets reaches the value of + this object and a new bucket is to be added to the + media-specific table, the oldest bucket associated + with this historyControlEntry shall be deleted by + the agent so that the new bucket can be added. + + When the value of this object changes to a value less + than the current value, entries are deleted + from the media-specific table associated with this + historyControlEntry. Enough of the oldest of these + entries shall be deleted by the agent so that their + number remains less than or equal to the new value of + this object. + + When the value of this object changes to a value + greater than the current value, the number of + associated media-specific entries may be allowed + to grow." + ::= { historyControlEntry 4 } + + historyControlInterval OBJECT-TYPE + SYNTAX INTEGER (1..3600) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval in seconds over which the data is + sampled for each bucket in the part of the + media-specific table associated with this + historyControl entry. This interval can + be set to any number of seconds between 1 and + + + 3600 (1 hour). + + Because the counters in a bucket may overflow at their + maximum value with no indication, a prudent manager + will take into account the possibility of overflow + in any of the associated counters. It is important + to consider the minimum time in which any counter + could overflow on a particular media type and set + the historyControlInterval object to a value less + than this interval. This is typically most + important for the 'octets' counter in any + media-specific table. For example, on an Ethernet + network, the etherHistoryOctets counter could overflow + in about one hour at the Ethernet's maximum + utilization. + + This object may not be modified if the associated + historyControlStatus object is equal to valid(1)." + DEFVAL { 1800 } + ::= { historyControlEntry 5 } + + historyControlOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is therefore + using the resources assigned to it." + ::= { historyControlEntry 6 } + + historyControlStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this historyControl entry. + + Each instance of the media-specific table associated + with this historyControlEntry will be deleted by the + agent if this historyControlEntry is not equal to + valid(1)." + ::= { historyControlEntry 7 } + + + -- Ether History table + + etherHistoryTable OBJECT-TYPE + SYNTAX SEQUENCE OF EtherHistoryEntry + + + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of Ethernet history entries." + ::= { history 2 } + + etherHistoryEntry OBJECT-TYPE + SYNTAX EtherHistoryEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "An historical sample of Ethernet statistics on a + particular Ethernet interface. This sample is + associated with the historyControlEntry which set + up the parameters for a regular collection of these + samples." + INDEX { etherHistoryIndex , etherHistorySampleIndex } + ::= { etherHistoryTable 1 } + + EtherHistoryEntry ::= SEQUENCE { + etherHistoryIndex INTEGER (1..65535), + etherHistorySampleIndex INTEGER, + etherHistoryIntervalStart TimeTicks, + etherHistoryDropEvents Counter, + etherHistoryOctets Counter, + etherHistoryPkts Counter, + etherHistoryBroadcastPkts Counter, + etherHistoryMulticastPkts Counter, + etherHistoryCRCAlignErrors Counter, + etherHistoryUndersizePkts Counter, + etherHistoryOversizePkts Counter, + etherHistoryFragments Counter, + etherHistoryJabbers Counter, + etherHistoryCollisions Counter, + etherHistoryUtilization INTEGER (0..10000) + } + + etherHistoryIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The history of which this entry is a part. The + history identified by a particular value of this + index is the same history as identified + by the same value of historyControlIndex." + ::= { etherHistoryEntry 1 } + + + + etherHistorySampleIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies the particular + sample this entry represents among all samples + associated with the same historyControlEntry. + This index starts at 1 and increases by one + as each new sample is taken." + ::= { etherHistoryEntry 2 } + + etherHistoryIntervalStart OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime at the start of the interval + over which this sample was measured. If the probe + keeps track of the time of day, it should start + the first sample of the history at a time such that + when the next hour of the day begins, a sample is + started at that instant. Note that following this + rule may require the probe to delay collecting the + first sample of the history, as each sample must be + of the same interval. Also note that the sample which + is currently being collected is not accessible in this + table until the end of its interval." + ::= { etherHistoryEntry 3 } + + etherHistoryDropEvents OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of events in which packets + were dropped by the probe due to lack of resources + during this interval. Note that this number is not + necessarily the number of packets dropped, it is just + the number of times this condition has been detected." + ::= { etherHistoryEntry 4 } + + etherHistoryOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of octets of data (including + + + those in bad packets) received on the + network (excluding framing bits but including + FCS octets)." + ::= { etherHistoryEntry 5 } + + etherHistoryPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets (including error packets) + received during this sampling interval." + ::= { etherHistoryEntry 6 } + + etherHistoryBroadcastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of good packets received during this + sampling interval that were directed to the + broadcast address." + ::= { etherHistoryEntry 7 } + + etherHistoryMulticastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of good packets received during this + sampling interval that were directed to a + multicast address. Note that this number does not + include packets addressed to the broadcast address." + ::= { etherHistoryEntry 8 } + + etherHistoryCRCAlignErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets received during this + sampling interval that had a length (excluding + framing bits but including FCS octets) between + 64 and 1518 octets, inclusive, but were not an + integral number of octets in length or had a + bad Frame Check Sequence (FCS)." + ::= { etherHistoryEntry 9 } + + + + etherHistoryUndersizePkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets received during this + interval that were less than 64 octets long + (excluding framing bits but including FCS + octets) and were otherwise well formed." + ::= { etherHistoryEntry 10 } + + etherHistoryOversizePkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets received during this + interval that were longer than 1518 octets + (excluding framing bits but including FCS + octets) but were otherwise well formed." + ::= { etherHistoryEntry 11 } + + etherHistoryFragments OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The total number of packets received during this + sampling interval that were not an integral + number of octets in length or that + had a bad Frame Check Sequence (FCS), and + were less than 64 octets in length (excluding + framing bits but including FCS octets)." + ::= { etherHistoryEntry 12 } + + etherHistoryJabbers OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets received during this + interval that were longer than 1518 octets + (excluding framing bits but including FCS octets), + and were not an integral number of octets in + length or had a bad Frame Check Sequence (FCS)." + ::= { etherHistoryEntry 13 } + + + + + etherHistoryCollisions OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The best estimate of the total number of collisions + on this Ethernet segment during this interval." + ::= { etherHistoryEntry 14 } + + etherHistoryUtilization OBJECT-TYPE + SYNTAX INTEGER (0..10000) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The best estimate of the mean physical layer + network utilization on this interface during this + interval, in hundredths of a percent." + ::= { etherHistoryEntry 15 } + + + -- The Alarm Group + + -- Implementation of the Alarm group is optional. + -- + -- The Alarm Group requires the implementation of the Event + -- group. + -- + -- The Alarm group periodically takes statistical samples from + -- variables in the probe and compares them to thresholds + -- that have been configured. The alarm table stores + -- configuration entries that each define a variable, + -- polling period, and threshold parameters. If a sample is + -- found to cross the threshold values, an event is + -- generated. Only variables that resolve to an ASN.1 + -- primitive type of INTEGER (INTEGER, Counter, + -- Gauge, or TimeTicks) may be monitored in this way. + -- + -- This function has a hysteresis mechanism to limit the + -- generation of events. This mechanism generates one event + -- as a threshold is crossed in the appropriate direction. + -- No more events are generated for that threshold until the + -- opposite threshold is crossed. + -- + -- In the case of a sampling a deltaValue, a probe may + -- implement this mechanism with more precision if it takes + -- a delta sample twice per period, each time comparing the + -- sum of the latest two samples to the threshold. This + -- allows the detection of threshold crossings + + + -- that span the sampling boundary. Note that this does not + -- require any special configuration of the threshold value. + -- It is suggested that probes implement this more precise + -- algorithm. + + alarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of alarm entries." + ::= { alarm 1 } + + alarmEntry OBJECT-TYPE + SYNTAX AlarmEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of parameters that set up a periodic checking + for alarm conditions." + INDEX { alarmIndex } + ::= { alarmTable 1 } + + AlarmEntry ::= SEQUENCE { + alarmIndex INTEGER (1..65535), + alarmInterval INTEGER, + alarmVariable OBJECT IDENTIFIER, + alarmSampleType INTEGER, + alarmValue INTEGER, + alarmStartupAlarm INTEGER, + alarmRisingThreshold INTEGER, + alarmFallingThreshold INTEGER, + alarmRisingEventIndex INTEGER (1..65535), + alarmFallingEventIndex INTEGER (1..65535), + alarmOwner OwnerString, + alarmStatus INTEGER + } + + alarmIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in the + alarm table. Each such entry defines a + diagnostic sample at a particular interval + for an object on the device." + ::= { alarmEntry 1 } + + + alarmInterval OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The interval in seconds over which the data is + sampled and compared with the rising and falling + thresholds. When setting this variable, care + should be given to ensure that the variable being + monitored will not exceed 2^31 - 1 and roll + over the alarmValue object during the interval. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 2 } + + alarmVariable OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The object identifier of the particular variable to + be sampled. Only variables that resolve to an ASN.1 + primitive type of INTEGER (INTEGER, Counter, Gauge, + or TimeTicks) may be sampled. + + Because SNMP access control is articulated entirely + in terms of the contents of MIB views, no access + control mechanism exists that can restrict the value of + this object to identify only those objects that exist + in a particular MIB view. Because there is thus no + acceptable means of restricting the read access that + could be obtained through the alarm mechanism, the + probe must only grant write access to this object in + those views that have read access to all objects on + the probe. + + During a set operation, if the supplied variable + name is not available in the selected MIB view, a + badValue error must be returned. If at any time + the variable name of an established alarmEntry is + no longer available in the selected MIB view, the + probe must change the status of this alarmEntry + to invalid(4). + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 3 } + + + alarmSampleType OBJECT-TYPE + SYNTAX INTEGER { + absoluteValue(1), + deltaValue(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The method of sampling the selected variable and + calculating the value to be compared against the + thresholds. If the value of this object is + absoluteValue(1), the value of the selected variable + will be compared directly with the thresholds at the + end of the sampling interval. If the value of this + object is deltaValue(2), the value of the selected + variable at the last sample will be subtracted from + the current value, and the difference compared with + the thresholds. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 4 } + + alarmValue OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of the statistic during the last sampling + period. The value during the current sampling period + is not made available until the period is completed." + ::= { alarmEntry 5 } + + alarmStartupAlarm OBJECT-TYPE + SYNTAX INTEGER { + risingAlarm(1), + fallingAlarm(2), + risingOrFallingAlarm(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The alarm that may be sent when this entry is first + set to valid. If the first sample after this entry + becomes valid is greater than or equal to the + risingThreshold and alarmStartupAlarm is equal to + risingAlarm(1) or risingOrFallingAlarm(3), then a + single rising alarm will be generated. If the first + + + sample after this entry becomes valid is less than + or equal to the fallingThreshold and + alarmStartupAlarm is equal to fallingAlarm(2) or + risingOrFallingAlarm(3), then a single falling + alarm will be generated. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 6 } + + alarmRisingThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold for the sampled statistic. When the + current sampled value is greater than or equal to + this threshold, and the value at the last sampling + interval was less than this threshold, a single + event will be generated. + A single event will also be generated if the first + sample after this entry becomes valid is greater + than or equal to this threshold and the associated + alarmStartupAlarm is equal to risingAlarm(1) or + risingOrFallingAlarm(3). + + After a rising event is generated, another such event + will not be generated until the sampled value + falls below this threshold and reaches the + alarmFallingThreshold. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 7 } + + alarmFallingThreshold OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A threshold for the sampled statistic. When the + current sampled value is less than or equal to + this threshold, and the value at the last sampling + interval was greater than this threshold, a single + event will be generated. + A single event will also be generated if the first + sample after this entry becomes valid is less than or + equal to this threshold and the associated + + + alarmStartupAlarm is equal to fallingAlarm(2) or + risingOrFallingAlarm(3). + + After a falling event is generated, another such event + will not be generated until the sampled value + rises above this threshold and reaches the + alarmRisingThreshold. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 8 } + + alarmRisingEventIndex OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The index of the eventEntry that is + used when a rising threshold is crossed. The + eventEntry identified by a particular value of + this index is the same as identified by the same value + of the eventIndex object. If there is no + corresponding entry in the eventTable, then + no association exists. In particular, if this value + is zero, no associated event will be generated, as + zero is not a valid event index. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + ::= { alarmEntry 9 } + + alarmFallingEventIndex OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The index of the eventEntry that is + used when a falling threshold is crossed. The + eventEntry identified by a particular value of + this index is the same as identified by the same value + of the eventIndex object. If there is no + corresponding entry in the eventTable, then + no association exists. In particular, if this value + is zero, no associated event will be generated, as + zero is not a valid event index. + + This object may not be modified if the associated + alarmStatus object is equal to valid(1)." + + + ::= { alarmEntry 10 } + + alarmOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is + therefore using the resources assigned to it." + ::= { alarmEntry 11 } + + alarmStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this alarm entry." + ::= { alarmEntry 12 } + + + -- The Host Group + + -- Implementation of the Host group is optional. + -- + -- The host group discovers new hosts on the network by + -- keeping a list of source and destination MAC Addresses seen + -- in good packets. For each of these addresses, the host + -- group keeps a set of statistics. The hostControlTable + -- controls which interfaces this function is performed on, + -- and contains some information about the process. On + -- behalf of each hostControlEntry, data is collected on an + -- interface and placed both the hostTable and the + -- hostTimeTable. If the monitoring device finds itself + -- short of resources, it may delete entries as needed. It + -- is suggested that the device delete the least recently + -- used entries first. + + -- The hostTable contains entries for each address + -- discovered on a particular interface. Each entry + -- contains statistical data about that host. This table + -- is indexed by the MAC address of the host, through + -- which a random access may be achieved. + + -- The hostTimeTable contains data in the same format as the + -- hostTable, and must contain the same set of hosts, but is + -- indexed using hostTimeCreationOrder rather than hostAddress. + -- The hostTimeCreationOrder is an integer which reflects + -- the relative order in which a particular entry was + + + -- discovered and thus inserted into the table. As this + -- order, and thus index, is among those entries currently + -- in the table, the index for a particular entry may change + -- if an (earlier) entry is deleted. Thus the association + -- between hostTimeCreationOrder and hostTimeEntry may be + -- broken at any time. + + -- The hostTimeTable has two important uses. The first is the + -- fast download of this potentially large table. Because the + -- index of this table runs from 1 to the size of the table, + -- inclusive, its values are predictable. This allows very + -- efficient packing of variables into SNMP PDU's and allows + -- a table transfer to have multiple packets outstanding. + -- These benefits increase transfer rates tremendously. + + -- The second use of the hostTimeTable is the efficient + -- discovery by the management station of new entries added + -- to the table. After the management station has + -- downloaded the entire table, it knows that new entries + -- will be added immediately after the end of the current + -- table. It can thus detect new entries there + -- and retrieve them easily. + + -- Because the association between hostTimeCreationOrder and + -- hostTimeEntry may be broken at any time, the management + -- station must monitor the related hostControlLastDeleteTime + -- object. When the management station thus detects a deletion, + -- it must assume that any such associations have been broken, + -- and invalidate any it has stored locally. This includes + -- restarting any download of the hostTimeTable that may have + -- been in progress, as well as rediscovering the end of the + -- hostTimeTable so that it may detect new entries. If the + -- management station does not detect the broken association, + -- it may continue to refer to a particular host by its + -- creationOrder while unwittingly retrieving the data + -- associated with another host entirely. If this happens + -- while downloading the host table, the management station + -- may fail to download all of the entries in the table. + + + hostControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF HostControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of host table control entries." + ::= { hosts 1 } + + + + hostControlEntry OBJECT-TYPE + SYNTAX HostControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of parameters that set up the discovery of + hosts on a particular interface and the collection + of statistics about these hosts." + INDEX { hostControlIndex } + ::= { hostControlTable 1 } + + HostControlEntry ::= SEQUENCE { + hostControlIndex INTEGER (1..65535), + hostControlDataSource OBJECT IDENTIFIER, + hostControlTableSize INTEGER, + hostControlLastDeleteTime TimeTicks, + hostControlOwner OwnerString, + hostControlStatus INTEGER + } + + hostControlIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in the + hostControl table. Each such entry defines + a function that discovers hosts on a particular + interface and places statistics about them in the + hostTable and the hostTimeTable on behalf of this + hostControlEntry." + ::= { hostControlEntry 1 } + + hostControlDataSource OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object identifies the source of the data for + this instance of the host function. This source + can be any interface on this device. In order + to identify a particular interface, this object shall + identify the instance of the ifIndex object, defined + in [4,6], for the desired interface. For example, + if an entry were to receive data from interface #1, + this object would be set to ifIndex.1. + + The statistics in this group reflect all packets + + + on the local network segment attached to the + identified interface. + + This object may not be modified if the associated + hostControlStatus object is equal to valid(1)." + ::= { hostControlEntry 2 } + + hostControlTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of hostEntries in the hostTable and the + hostTimeTable associated with this hostControlEntry." + ::= { hostControlEntry 3 } + + hostControlLastDeleteTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime when the last entry + was deleted from the portion of the hostTable + associated with this hostControlEntry. If no + deletions have occurred, this value shall be zero." + ::= { hostControlEntry 4 } + + hostControlOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is + therefore using the resources assigned to it." + ::= { hostControlEntry 5 } + + hostControlStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this hostControl entry. + + If this object is not equal to valid(1), all + associated entries in the hostTable, + hostTimeTable, and the hostTopNTable shall be + deleted by the agent." + ::= { hostControlEntry 6 } + + + hostTable OBJECT-TYPE + SYNTAX SEQUENCE OF HostEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of host entries." + ::= { hosts 2 } + + hostEntry OBJECT-TYPE + SYNTAX HostEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A collection of statistics for a particular host + that has been discovered on an interface of this + device." + INDEX { hostIndex, hostAddress } + ::= { hostTable 1 } + + HostEntry ::= SEQUENCE { + hostAddress OCTET STRING, + hostCreationOrder INTEGER (1..65535), + hostIndex INTEGER (1..65535), + hostInPkts Counter, + hostOutPkts Counter, + hostInOctets Counter, + hostOutOctets Counter, + hostOutErrors Counter, + hostOutBroadcastPkts Counter, + hostOutMulticastPkts Counter + } + + hostAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical address of this host." + ::= { hostEntry 1 } + + hostCreationOrder OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that defines the relative ordering of + the creation time of hosts captured for a + particular hostControlEntry. This index shall + + + be between 1 and N, where N is the value of + the associated hostControlTableSize. The ordering + of the indexes is based on the order of each entry's + insertion into the table, in which entries added + earlier have a lower index value than entries added + later. + + It is important to note that the order for a + particular entry may change as an (earlier) entry + is deleted from the table. Because this order may + change, management stations should make use of the + hostControlLastDeleteTime variable in the + hostControlEntry associated with the relevant + portion of the hostTable. By observing + this variable, the management station may detect + the circumstances where a previous association + between a value of hostCreationOrder + and a hostEntry may no longer hold." + ::= { hostEntry 2 } + + hostIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The set of collected host statistics of which + this entry is a part. The set of hosts + identified by a particular value of this + index is associated with the hostControlEntry + as identified by the same value of hostControlIndex." + ::= { hostEntry 3 } + + hostInPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets without errors transmitted to + this address since it was added to the hostTable." + ::= { hostEntry 4 } + + hostOutPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets including errors transmitted + by this address since it was added to the hostTable." + + + ::= { hostEntry 5 } + + hostInOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of octets transmitted to this address + since it was added to the hostTable (excluding + framing bits but including FCS octets), except for + those octets in packets that contained errors." + ::= { hostEntry 6 } + + hostOutOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of octets transmitted by this address + since it was added to the hostTable (excluding + framing bits but including FCS octets), including + those octets in packets that contained errors." + ::= { hostEntry 7 } + + hostOutErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of error packets transmitted by this + address since this host was added to the hostTable." + ::= { hostEntry 8 } + + hostOutBroadcastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of good packets transmitted by this + address that were directed to the broadcast address + since this host was added to the hostTable." + ::= { hostEntry 9 } + + hostOutMulticastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + + + "The number of good packets transmitted by this + address that were directed to a multicast address + since this host was added to the hostTable. + Note that this number does not include packets + directed to the broadcast address." + ::= { hostEntry 10 } + + + -- host Time Table + + hostTimeTable OBJECT-TYPE + SYNTAX SEQUENCE OF HostTimeEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of time-ordered host table entries." + ::= { hosts 3 } + + hostTimeEntry OBJECT-TYPE + SYNTAX HostTimeEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A collection of statistics for a particular host + that has been discovered on an interface of this + device. This collection includes the relative + ordering of the creation time of this object." + INDEX { hostTimeIndex, hostTimeCreationOrder } + ::= { hostTimeTable 1 } + + HostTimeEntry ::= SEQUENCE { + hostTimeAddress OCTET STRING, + hostTimeCreationOrder INTEGER (1..65535), + hostTimeIndex INTEGER (1..65535), + hostTimeInPkts Counter, + hostTimeOutPkts Counter, + hostTimeInOctets Counter, + hostTimeOutOctets Counter, + hostTimeOutErrors Counter, + hostTimeOutBroadcastPkts Counter, + hostTimeOutMulticastPkts Counter + } + + hostTimeAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + + + "The physical address of this host." + ::= { hostTimeEntry 1 } + + hostTimeCreationOrder OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in + the hostTime table among those entries associated + with the same hostControlEntry. This index shall + be between 1 and N, where N is the value of + the associated hostControlTableSize. The ordering + of the indexes is based on the order of each entry's + insertion into the table, in which entries added + earlier have a lower index value than entries added + later. Thus the management station has the ability + to learn of new entries added to this table without + downloading the entire table. + + It is important to note that the index for a + particular entry may change as an (earlier) entry + is deleted from the table. Because this order may + change, management stations should make use of the + hostControlLastDeleteTime variable in the + hostControlEntry associated with the relevant + portion of the hostTimeTable. By observing + this variable, the management station may detect + the circumstances where a download of the table + may have missed entries, and where a previous + association between a value of hostTimeCreationOrder + and a hostTimeEntry may no longer hold." + ::= { hostTimeEntry 2 } + + hostTimeIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The set of collected host statistics of which + this entry is a part. The set of hosts + identified by a particular value of this + index is associated with the hostControlEntry + as identified by the same value of hostControlIndex." + ::= { hostTimeEntry 3 } + + + + + + hostTimeInPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets without errors transmitted to + this address since it was added to the hostTimeTable." + ::= { hostTimeEntry 4 } + + hostTimeOutPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets including errors transmitted + by this address since it was added to the + hostTimeTable." + ::= { hostTimeEntry 5 } + + hostTimeInOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of octets transmitted to this address + since it was added to the hostTimeTable (excluding + framing bits but including FCS octets), except for + those octets in packets that contained errors." + ::= { hostTimeEntry 6 } + + hostTimeOutOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of octets transmitted by this address since + it was added to the hostTimeTable (excluding framing + bits but including FCS octets), including those + octets in packets that contained errors." + ::= { hostTimeEntry 7 } + + hostTimeOutErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of error packets transmitted by this + address since this host was added to the + + + hostTimeTable." + ::= { hostTimeEntry 8 } + + hostTimeOutBroadcastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of good packets transmitted by this + address that were directed to the broadcast address + since this host was added to the hostTimeTable." + ::= { hostTimeEntry 9 } + + hostTimeOutMulticastPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of good packets transmitted by this + address that were directed to a multicast address + since this host was added to the hostTimeTable. + Note that this number does not include packets + directed to the broadcast address." + ::= { hostTimeEntry 10 } + + + -- The Host Top "N" Group + + -- Implementation of the Host Top N group is optional. + -- + -- The Host Top N group requires the implementation of the + -- host group. + -- + -- The Host Top N group is used to prepare reports that + -- describe the hosts that top a list ordered by one of + -- their statistics. The available statistics are samples + -- of one of their base statistics, over an interval + -- specified by the management station. Thus, these + -- statistics are rate based. The management + -- station also selects how many such hosts are reported. + + -- The hostTopNControlTable is used to initiate the generation + -- of such a report. The management station may select the + -- parameters of such a report, such as which interface, + -- which statistic, how many hosts, and the start and stop + -- times of the sampling. When the report is prepared, + -- entries are created in the hostTopNTable associated with + -- the relevant hostTopNControlEntry. These entries are + + + -- static for each report after it has been prepared. + + hostTopNControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF HostTopNControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of top N host control entries." + ::= { hostTopN 1 } + + hostTopNControlEntry OBJECT-TYPE + SYNTAX HostTopNControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of parameters that control the creation of a + report of the top N hosts according to several + metrics." + INDEX { hostTopNControlIndex } + ::= { hostTopNControlTable 1 } + + HostTopNControlEntry ::= SEQUENCE { + hostTopNControlIndex INTEGER (1..65535), + hostTopNHostIndex INTEGER (1..65535), + hostTopNRateBase INTEGER, + hostTopNTimeRemaining INTEGER, + hostTopNDuration INTEGER, + hostTopNRequestedSize INTEGER, + hostTopNGrantedSize INTEGER, + hostTopNStartTime TimeTicks, + hostTopNOwner OwnerString, + hostTopNStatus INTEGER + } + + hostTopNControlIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry + in the hostTopNControl table. Each such + entry defines one top N report prepared for + one interface." + ::= { hostTopNControlEntry 1 } + + hostTopNHostIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + + + STATUS mandatory + DESCRIPTION + "The host table for which a top N report will be + prepared on behalf of this entry. The host table + identified by a particular value of this index is + associated with the same host table as identified + by the same value of hostIndex. + + This object may not be modified if the associated + hostTopNStatus object is equal to valid(1)." + ::= { hostTopNControlEntry 2 } + + hostTopNRateBase OBJECT-TYPE + SYNTAX INTEGER { + hostTopNInPkts(1), + hostTopNOutPkts(2), + hostTopNInOctets(3), + hostTopNOutOctets(4), + hostTopNOutErrors(5), + hostTopNOutBroadcastPkts(6), + hostTopNOutMulticastPkts(7) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The variable for each host that the hostTopNRate + variable is based upon. + + This object may not be modified if the associated + hostTopNStatus object is equal to valid(1)." + ::= { hostTopNControlEntry 3 } + + hostTopNTimeRemaining OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The number of seconds left in the report currently + being collected. When this object is modified by + the management station, a new collection is started, + possibly aborting a currently running report. The + new value is used as the requested duration of this + report, which is loaded into the associated + hostTopNDuration object. + + When this object is set to a non-zero value, any + associated hostTopNEntries shall be made + inaccessible by the monitor. While the value of this + + + object is non-zero, it decrements by one per second + until it reaches zero. During this time, all + associated hostTopNEntries shall remain + inaccessible. At the time that this object + decrements to zero, the report is made + accessible in the hostTopNTable. Thus, the hostTopN + table needs to be created only at the end of the + collection interval." + DEFVAL { 0 } + ::= { hostTopNControlEntry 4 } + + hostTopNDuration OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of seconds that this report has collected + during the last sampling interval, or if this + report is currently being collected, the number + of seconds that this report is being collected + during this sampling interval. + + When the associated hostTopNTimeRemaining object is + set, this object shall be set by the probe to the + same value and shall not be modified until the next + time the hostTopNTimeRemaining is set. + + This value shall be zero if no reports have been + requested for this hostTopNControlEntry." + DEFVAL { 0 } + ::= { hostTopNControlEntry 5 } + + hostTopNRequestedSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum number of hosts requested for the top N + table. + + When this object is created or modified, the probe + should set hostTopNGrantedSize as closely to this + object as is possible for the particular probe + implementation and available resources." + DEFVAL { 10 } + ::= { hostTopNControlEntry 6 } + + + + + hostTopNGrantedSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum number of hosts in the top N table. + + When the associated hostTopNRequestedSize object is + created or modified, the probe should set this + object as closely to the requested value as is + possible for the particular implementation and + available resources. The probe must not lower this + value except as a result of a set to the associated + hostTopNRequestedSize object. + + Hosts with the highest value of hostTopNRate shall be + placed in this table in decreasing order of this rate + until there is no more room or until there are no more + hosts." + ::= { hostTopNControlEntry 7 } + + hostTopNStartTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime when this top N report was + last started. In other words, this is the time that + the associated hostTopNTimeRemaining object was + modified to start the requested report." + ::= { hostTopNControlEntry 8 } + + hostTopNOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is + therefore using the resources assigned to it." + ::= { hostTopNControlEntry 9 } + + hostTopNStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this hostTopNControl entry. + + + + If this object is not equal to valid(1), all + associated hostTopNEntries shall be deleted by + the agent." + ::= { hostTopNControlEntry 10 } + + hostTopNTable OBJECT-TYPE + SYNTAX SEQUENCE OF HostTopNEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of top N host entries." + ::= { hostTopN 2 } + + hostTopNEntry OBJECT-TYPE + SYNTAX HostTopNEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of statistics for a host that is part of a + top N report." + INDEX { hostTopNReport, hostTopNIndex } + ::= { hostTopNTable 1 } + + HostTopNEntry ::= SEQUENCE { + hostTopNReport INTEGER (1..65535), + hostTopNIndex INTEGER (1..65535), + hostTopNAddress OCTET STRING, + hostTopNRate INTEGER + } + + hostTopNReport OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object identifies the top N report of which + this entry is a part. The set of hosts + identified by a particular value of this + object is part of the same report as identified + by the same value of the hostTopNControlIndex object." + ::= { hostTopNEntry 1 } + + hostTopNIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in + + + the hostTopN table among those in the same report. + This index is between 1 and N, where N is the + number of entries in this table. Increasing values + of hostTopNIndex shall be assigned to entries with + decreasing values of hostTopNRate until index N + is assigned to the entry with the lowest value of + hostTopNRate or there are no more hostTopNEntries." + ::= { hostTopNEntry 2 } + + hostTopNAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The physical address of this host." + ::= { hostTopNEntry 3 } + + hostTopNRate OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The amount of change in the selected variable + during this sampling interval. The selected + variable is this host's instance of the object + selected by hostTopNRateBase." + ::= { hostTopNEntry 4 } + + + -- The Matrix Group + + -- Implementation of the Matrix group is optional. + -- + -- The Matrix group consists of the matrixControlTable, + -- matrixSDTable and the matrixDSTable. These tables + -- store statistics for a particular conversation between + -- two addresses. As the device detects a new conversation, + -- including those to a non-unicast address, it creates a + -- new entry in both of the matrix tables. + -- It must only create new entries based on information + -- received in good packets. If the monitoring device finds + -- itself short of resources, it may delete entries as needed. + -- It is suggested that the device delete the least recently + -- used entries first. + + matrixControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF MatrixControlEntry + ACCESS not-accessible + + + STATUS mandatory + DESCRIPTION + "A list of information entries for the + traffic matrix on each interface." + ::= { matrix 1 } + + matrixControlEntry OBJECT-TYPE + SYNTAX MatrixControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "Information about a traffic matrix on a + particular interface." + INDEX { matrixControlIndex } + ::= { matrixControlTable 1 } + + MatrixControlEntry ::= SEQUENCE { + matrixControlIndex INTEGER (1..65535), + matrixControlDataSource OBJECT IDENTIFIER, + matrixControlTableSize INTEGER, + matrixControlLastDeleteTime TimeTicks, + matrixControlOwner OwnerString, + matrixControlStatus INTEGER + } + + matrixControlIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in the + matrixControl table. Each such entry defines + a function that discovers conversations on a particular + interface and places statistics about them in the + matrixSDTable and the matrixDSTable on behalf of this + matrixControlEntry." + ::= { matrixControlEntry 1 } + + matrixControlDataSource OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object identifies the source of + the data from which this entry creates a traffic matrix. + This source can be any interface on this device. In + order to identify a particular interface, this object + shall identify the instance of the ifIndex object, + + + defined in [4,6], for the desired interface. For + example, if an entry were to receive data from + interface #1, this object would be set to ifIndex.1. + + The statistics in this group reflect all packets + on the local network segment attached to the + identified interface. + + This object may not be modified if the associated + matrixControlStatus object is equal to valid(1)." + ::= { matrixControlEntry 2 } + + matrixControlTableSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of matrixSDEntries in the matrixSDTable + for this interface. This must also be the value of + the number of entries in the matrixDSTable for this + interface." + ::= { matrixControlEntry 3 } + + matrixControlLastDeleteTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime when the last entry + was deleted from the portion of the matrixSDTable + or matrixDSTable associated with this + matrixControlEntry. + If no deletions have occurred, this value shall be + zero." + ::= { matrixControlEntry 4 } + + matrixControlOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is + therefore using the resources assigned to it." + ::= { matrixControlEntry 5 } + + matrixControlStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + + + STATUS mandatory + DESCRIPTION + "The status of this matrixControl entry. + + If this object is not equal to valid(1), all + associated entries in the matrixSDTable and the + matrixDSTable shall be deleted by the agent." + ::= { matrixControlEntry 6 } + + matrixSDTable OBJECT-TYPE + SYNTAX SEQUENCE OF MatrixSDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of traffic matrix entries indexed by + source and destination MAC address." + ::= { matrix 2 } + + matrixSDEntry OBJECT-TYPE + SYNTAX MatrixSDEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A collection of statistics for communications between + two addresses on a particular interface." + INDEX { matrixSDIndex, + matrixSDSourceAddress, matrixSDDestAddress } + ::= { matrixSDTable 1 } + + MatrixSDEntry ::= SEQUENCE { + matrixSDSourceAddress OCTET STRING, + matrixSDDestAddress OCTET STRING, + matrixSDIndex INTEGER (1..65535), + matrixSDPkts Counter, + matrixSDOctets Counter, + matrixSDErrors Counter + } + + matrixSDSourceAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The source physical address." + ::= { matrixSDEntry 1 } + + + + + + matrixSDDestAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The destination physical address." + ::= { matrixSDEntry 2 } + + matrixSDIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The set of collected matrix statistics of which + this entry is a part. The set of matrix statistics + identified by a particular value of this index + is associated with the same matrixControlEntry + as identified by the same value of matrixControlIndex." + ::= { matrixSDEntry 3 } + + matrixSDPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets transmitted from the source + address to the destination address (this number + includes error packets)." + ::= { matrixSDEntry 4 } + + matrixSDOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of octets (excluding framing bits but + including FCS octets) contained in all packets + transmitted from the source address to the + destination address." + ::= { matrixSDEntry 5 } + + matrixSDErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of error packets transmitted from + the source address to the destination address." + + + ::= { matrixSDEntry 6 } + + + -- Traffic matrix tables from destination to source + + matrixDSTable OBJECT-TYPE + SYNTAX SEQUENCE OF MatrixDSEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of traffic matrix entries indexed by + destination and source MAC address." + ::= { matrix 3 } + + matrixDSEntry OBJECT-TYPE + SYNTAX MatrixDSEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A collection of statistics for communications between + two address on a particular interface." + INDEX { matrixDSIndex, + matrixDSDestAddress, matrixDSSourceAddress } + ::= { matrixDSTable 1 } + + MatrixDSEntry ::= SEQUENCE { + matrixDSSourceAddress OCTET STRING, + matrixDSDestAddress OCTET STRING, + matrixDSIndex INTEGER (1..65535), + matrixDSPkts Counter, + matrixDSOctets Counter, + matrixDSErrors Counter + } + + matrixDSSourceAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The source physical address." + ::= { matrixDSEntry 1 } + + matrixDSDestAddress OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The destination physical address." + + + ::= { matrixDSEntry 2 } + + matrixDSIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The set of collected matrix statistics of which + this entry is a part. The set of matrix statistics + identified by a particular value of this index + is associated with the same matrixControlEntry + as identified by the same value of matrixControlIndex." + ::= { matrixDSEntry 3 } + + matrixDSPkts OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets transmitted from the source + address to the destination address (this number + includes error packets)." + ::= { matrixDSEntry 4 } + + matrixDSOctets OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of octets (excluding framing bits + but including FCS octets) contained in all packets + transmitted from the source address to the + destination address." + ::= { matrixDSEntry 5 } + + matrixDSErrors OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of error packets transmitted from + the source address to the destination address." + ::= { matrixDSEntry 6 } + + + -- The Filter Group + + -- Implementation of the Filter group is optional. + + + -- + -- The Filter group allows packets to be captured with an + -- arbitrary filter expression. A logical data and + -- event stream or "channel" is formed by the packets + -- that match the filter expression. + -- + -- This filter mechanism allows the creation of an arbitrary + -- logical expression with which to filter packets. Each + -- filter associated with a channel is OR'ed with the others. + -- Within a filter, any bits checked in the data and status are + -- AND'ed with respect to other bits in the same filter. The + -- NotMask also allows for checking for inequality. Finally, + -- the channelAcceptType object allows for inversion of the + -- whole equation. + -- + -- The channel can be turned on or off, and can also + -- generate events when packets pass through it. + + filterTable OBJECT-TYPE + SYNTAX SEQUENCE OF FilterEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of packet filter entries." + ::= { filter 1 } + + filterEntry OBJECT-TYPE + SYNTAX FilterEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of parameters for a packet filter applied on a + particular interface." + INDEX { filterIndex } + ::= { filterTable 1 } + + FilterEntry ::= SEQUENCE { + filterIndex INTEGER (1..65535), + filterChannelIndex INTEGER (1..65535), + filterPktDataOffset INTEGER, + filterPktData OCTET STRING, + filterPktDataMask OCTET STRING, + filterPktDataNotMask OCTET STRING, + filterPktStatus INTEGER, + filterPktStatusMask INTEGER, + filterPktStatusNotMask INTEGER, + filterOwner OwnerString, + filterStatus INTEGER + + + } + + filterIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry + in the filter table. Each such entry defines + one filter that is to be applied to every packet + received on an interface." + ::= { filterEntry 1 } + + filterChannelIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object identifies the channel of which this + filter is a part. The filters identified by a + particular value of this object are associated + with the same channel as identified by the same + value of the channelIndex object." + ::= { filterEntry 2 } + + filterPktDataOffset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The offset from the beginning of each packet where + a match of packet data will be attempted. This offset + is measured from the point in the physical layer + packet after the framing bits, if any. For example, + in an Ethernet frame, this point is at the beginning + of the destination MAC address. + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + DEFVAL { 0 } + ::= { filterEntry 3 } + + filterPktData OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The data that is to be matched with the input packet. + + + For each packet received, this filter and the + accompanying filterPktDataMask and + filterPktDataNotMask will be adjusted for the + offset. The only bits relevant to this + match algorithm are those that have the corresponding + filterPktDataMask bit equal to one. The following + three rules are then applied to every packet: + + (1) If the packet is too short and does not have data + corresponding to part of the filterPktData, the + packet will fail this data match. + + (2) For each relevant bit from the packet with the + corresponding filterPktDataNotMask bit set to + zero, if the bit from the packet is not equal to + the corresponding bit from the filterPktData, + then the packet will fail this data match. + + (3) If for every relevant bit from the packet with the + corresponding filterPktDataNotMask bit set to one, + the bit from the packet is equal to the + corresponding bit from the filterPktData, then + the packet will fail this data match. + + Any packets that have not failed any of the three + matches above have passed this data match. + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + ::= { filterEntry 4 } + + filterPktDataMask OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The mask that is applied to the match process. + After adjusting this mask for the offset, only those + bits in the received packet that correspond to bits + set in this mask are relevant for further processing + by the match algorithm. The offset is applied to + filterPktDataMask in the same way it is applied to + the filter. For the purposes of the matching + algorithm, if the associated filterPktData object + is longer than this mask, this mask is conceptually + extended with '1' bits until it reaches the + length of the filterPktData object. + + + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + ::= { filterEntry 5 } + + filterPktDataNotMask OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The inversion mask that is applied to the match + process. After adjusting this mask for the offset, + those relevant bits in the received packet that + correspond to bits cleared in this mask must all + be equal to their corresponding bits in the + filterPktData object for the packet to be accepted. + In addition, at least one of those relevant + bits in the received packet that correspond to bits + set in this mask must be different to its + corresponding bit in the filterPktData object. + + For the purposes of the matching algorithm, if + the associated filterPktData object is longer than + this mask, this mask is conceptually extended with + '0' bits until it reaches the length of the + filterPktData object. + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + ::= { filterEntry 6 } + + filterPktStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status that is to be matched with the input + packet. The only bits relevant to this match + algorithm are those that have the corresponding + filterPktStatusMask bit equal to one. + + The following two rules are then applied to every + packet: + + (1) For each relevant bit from the packet status + with the corresponding filterPktStatusNotMask + bit set to zero, if the bit from the packet + status is not equal to the corresponding bit + from the filterPktStatus, then the packet will + + + fail this status match. + + (2) If for every relevant bit from the packet status + with the corresponding filterPktStatusNotMask + bit set to one, the bit from the packet status + is equal to the corresponding bit from the + filterPktStatus, then the packet will fail + this status match. + + Any packets that have not failed either of the two + matches above have passed this status match. + + The value of the packet status is a sum. This sum + initially takes the value zero. Then, for each + error, E, that has been discovered in this packet, + 2 raised to a value representing E is added to the sum. + The errors and the bits that represent them are + dependent on the media type of the interface that + this channel is receiving packets from. + + The errors defined for a packet captured off of an + Ethernet interface are as follows: + + bit # Error + 0 Packet is longer than 1518 octets + 1 Packet is shorter than 64 octets + 2 Packet experienced a CRC or Alignment + error + + For example, an Ethernet fragment would have a + value of 6 (2^1 + 2^2). + + As this MIB is expanded to new media types, this + object will have other media-specific errors defined. + + For the purposes of this status matching algorithm, if + the packet status is longer than this + object, filterPktStatus this object is conceptually + extended with '0' bits until it reaches the size of + the packet status. + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + ::= { filterEntry 7 } + + filterPktStatusMask OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + + + STATUS mandatory + DESCRIPTION + "The mask that is applied to the status match process. + Only those bits in the received packet that correspond + to bits set in this mask are relevant for further + processing by the status match algorithm. For the + purposes of the matching algorithm, if the + associated filterPktStatus object is longer than + this mask, this mask is conceptually extended with + '1' bits until it reaches the size of the + filterPktStatus. In addition, if a packet status is + longer than this mask, this mask is conceptually + extended with '0' bits until it reaches the size of + the packet status. + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + ::= { filterEntry 8 } + + filterPktStatusNotMask OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The inversion mask that is applied to the status match + process. Those relevant bits in the received packet + status that correspond to bits cleared in this mask + must all be equal to their corresponding bits in the + filterPktStatus object for the packet to be accepted. + In addition, at least one of those relevant bits in the + received packet status that correspond to bits set in + this mask must be different to its corresponding bit + in the filterPktStatus object for the packet to be + accepted. + + For the purposes of the matching algorithm, if the + associated filterPktStatus object or a packet status + is longer than this mask, this mask is conceptually + extended with '0' bits until it reaches the longer of + the lengths of the filterPktStatus object and the + packet status. + + This object may not be modified if the associated + filterStatus object is equal to valid(1)." + ::= { filterEntry 9 } + + filterOwner OBJECT-TYPE + SYNTAX OwnerString + + + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is + therefore using the resources assigned to it." + ::= { filterEntry 10 } + + filterStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this filter entry." + ::= { filterEntry 11 } + + channelTable OBJECT-TYPE + SYNTAX SEQUENCE OF ChannelEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of packet channel entries." + ::= { filter 2 } + + channelEntry OBJECT-TYPE + SYNTAX ChannelEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of parameters for a packet channel applied on a + particular interface." + INDEX { channelIndex } + ::= { channelTable 1 } + + ChannelEntry ::= SEQUENCE { + channelIndex INTEGER (1..65535), + channelIfIndex INTEGER (1..65535), + channelAcceptType INTEGER, + channelDataControl INTEGER, + channelTurnOnEventIndex INTEGER (0..65535), + channelTurnOffEventIndex INTEGER (0..65535), + channelEventIndex INTEGER (0..65535), + channelEventStatus INTEGER, + channelMatches Counter, + channelDescription DisplayString (SIZE (0..127)), + channelOwner OwnerString, + channelStatus INTEGER + } + + + + channelIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry + in the channel table. Each such + entry defines one channel, a logical data + and event stream." + ::= { channelEntry 1 } + + channelIfIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of this object uniquely identifies the + interface on this remote network monitoring device + to which the associated filters are applied to allow + data into this channel. The interface identified by + a particular value of this object is the same + interface as identified by the same value of the + ifIndex object, defined in [4,6]. The filters in + this group are applied to all packets on the local + network segment attached to the identified + interface. + + This object may not be modified if the associated + channelStatus object is equal to valid(1)." + ::= { channelEntry 2 } + + channelAcceptType OBJECT-TYPE + SYNTAX INTEGER { + acceptMatched(1), + acceptFailed(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls the action of the filters + associated with this channel. If this object is equal + to acceptMatched(1), packets will be accepted to this + channel if they are accepted by both the packet data + and packet status matches of an associated filter. If + this object is equal to acceptFailed(2), packets will + be accepted to this channel only if they fail either + the packet data match or the packet status match of + each of the associated filters. + + + This object may not be modified if the associated + channelStatus object is equal to valid(1)." + ::= { channelEntry 3 } + + channelDataControl OBJECT-TYPE + SYNTAX INTEGER { + on(1), + off(2) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "This object controls the flow of data through this + channel. If this object is on(1), data, status and + events flow through this channel. If this object is + off(2), data, status and events will not flow through + this channel." + DEFVAL { off } + ::= { channelEntry 4 } + + channelTurnOnEventIndex OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of this object identifies the event + that is configured to turn the associated + channelDataControl from off to on when the event is + generated. The event identified by a particular value + of this object is the same event as identified by the + same value of the eventIndex object. If there is no + corresponding entry in the eventTable, then no + association exists. In fact, if no event is intended + for this channel, channelTurnOnEventIndex must be + set to zero, a non-existent event index. + + This object may not be modified if the associated + channelStatus object is equal to valid(1)." + ::= { channelEntry 5 } + + channelTurnOffEventIndex OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of this object identifies the event + that is configured to turn the associated + channelDataControl from on to off when the event is + + + generated. The event identified by a particular value + of this object is the same event as identified by the + same value of the eventIndex object. If there is no + corresponding entry in the eventTable, then no + association exists. In fact, if no event is intended + for this channel, channelTurnOffEventIndex must be + set to zero, a non-existent event index. + + This object may not be modified if the associated + channelStatus object is equal to valid(1)." + ::= { channelEntry 6 } + + channelEventIndex OBJECT-TYPE + SYNTAX INTEGER (0..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The value of this object identifies the event + that is configured to be generated when the + associated channelDataControl is on and a packet + is matched. The event identified by a particular value + of this object is the same event as identified by the + same value of the eventIndex object. If there is no + corresponding entry in the eventTable, then no + association exists. In fact, if no event is intended + for this channel, channelEventIndex must be + set to zero, a non-existent event index. + + This object may not be modified if the associated + channelStatus object is equal to valid(1)." + ::= { channelEntry 7 } + + channelEventStatus OBJECT-TYPE + SYNTAX INTEGER { + eventReady(1), + eventFired(2), + eventAlwaysReady(3) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The event status of this channel. + + If this channel is configured to generate events + when packets are matched, a means of controlling + the flow of those events is often needed. When + this object is equal to eventReady(1), a single + event may be generated, after which this object + + + will be set by the probe to eventFired(2). While + in the eventFired(2) state, no events will be + generated until the object is modified to + eventReady(1) (or eventAlwaysReady(3)). The + management station can thus easily respond to a + notification of an event by re-enabling this object. + + If the management station wishes to disable this + flow control and allow events to be generated + at will, this object may be set to + eventAlwaysReady(3). Disabling the flow control + is discouraged as it can result in high network + traffic or other performance problems." + DEFVAL { eventReady } + ::= { channelEntry 8 } + + channelMatches OBJECT-TYPE + SYNTAX Counter + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of times this channel has matched a packet. + Note that this object is updated even when + channelDataControl is set to off." + ::= { channelEntry 9 } + + channelDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A comment describing this channel." + ::= { channelEntry 10 } + + channelOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is therefore + using the resources assigned to it." + ::= { channelEntry 11 } + + channelStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + + + "The status of this channel entry." + ::= { channelEntry 12 } + + + -- The Packet Capture Group + + -- Implementation of the Packet Capture group is optional. + -- + -- The Packet Capture Group requires implementation of the + -- Filter Group. + -- + -- The Packet Capture group allows packets to be captured + -- upon a filter match. The bufferControlTable controls + -- the captured packets output from a channel that is + -- associated with it. The captured packets are placed + -- in entries in the captureBufferTable. These entries are + -- associated with the bufferControlEntry on whose behalf they + -- were stored. + + bufferControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF BufferControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of buffers control entries." + ::= { capture 1 } + + bufferControlEntry OBJECT-TYPE + SYNTAX BufferControlEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of parameters that control the collection of + a stream of packets that have matched filters." + INDEX { bufferControlIndex } + ::= { bufferControlTable 1 } + + BufferControlEntry ::= SEQUENCE { + bufferControlIndex INTEGER (1..65535), + bufferControlChannelIndex INTEGER (1..65535), + bufferControlFullStatus INTEGER, + bufferControlFullAction INTEGER, + bufferControlCaptureSliceSize INTEGER, + bufferControlDownloadSliceSize INTEGER, + bufferControlDownloadOffset INTEGER, + bufferControlMaxOctetsRequested INTEGER, + bufferControlMaxOctetsGranted INTEGER, + bufferControlCapturedPackets INTEGER, + + + bufferControlTurnOnTime TimeTicks, + bufferControlOwner OwnerString, + bufferControlStatus INTEGER + } + + bufferControlIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry + in the bufferControl table. The value of this + index shall never be zero. Each such + entry defines one set of packets that is + captured and controlled by one or more filters." + ::= { bufferControlEntry 1 } + + bufferControlChannelIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "An index that identifies the channel that is the + source of packets for this bufferControl table. + The channel identified by a particular value of this + index is the same as identified by the same value of + the channelIndex object. + + This object may not be modified if the associated + bufferControlStatus object is equal to valid(1)." + ::= { bufferControlEntry 2 } + + bufferControlFullStatus OBJECT-TYPE + SYNTAX INTEGER { + spaceAvailable(1), + full(2) + } + ACCESS read-only + STATUS mandatory + DESCRIPTION + "This object shows whether the buffer has room to + accept new packets or if it is full. + + If the status is spaceAvailable(1), the buffer is + accepting new packets normally. If the status is + full(2) and the associated bufferControlFullAction + object is wrapWhenFull, the buffer is accepting new + packets by deleting enough of the oldest packets + + + to make room for new ones as they arrive. Otherwise, + if the status is full(2) and the + bufferControlFullAction object is lockWhenFull, + then the buffer has stopped collecting packets. + + When this object is set to full(2) the probe must + not later set it to spaceAvailable(1) except in the + case of a significant gain in resources such as + an increase of bufferControlOctetsGranted. In + particular, the wrap-mode action of deleting old + packets to make room for newly arrived packets + must not affect the value of this object." + ::= { bufferControlEntry 3 } + + bufferControlFullAction OBJECT-TYPE + SYNTAX INTEGER { + lockWhenFull(1), + wrapWhenFull(2) -- FIFO + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "Controls the action of the buffer when it + reaches the full status. When in the lockWhenFull(1) + state a packet is added to the buffer that + fills the buffer, the bufferControlFullStatus will + be set to full(2) and this buffer will stop capturing + packets." + ::= { bufferControlEntry 4 } + + bufferControlCaptureSliceSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum number of octets of each packet + that will be saved in this capture buffer. + For example, if a 1500 octet packet is received by + the probe and this object is set to 500, then only + 500 octets of the packet will be stored in the + associated capture buffer. If this variable is set + to 0, the capture buffer will save as many octets + as is possible. + + This object may not be modified if the associated + bufferControlStatus object is equal to valid(1)." + DEFVAL { 100 } + ::= { bufferControlEntry 5 } + + + bufferControlDownloadSliceSize OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The maximum number of octets of each packet + in this capture buffer that will be returned in + an SNMP retrieval of that packet. For example, + if 500 octets of a packet have been stored in the + associated capture buffer, the associated + bufferControlDownloadOffset is 0, and this + object is set to 100, then the captureBufferPacket + object that contains the packet will contain only + the first 100 octets of the packet. + + A prudent manager will take into account possible + interoperability or fragmentation problems that may + occur if the download slice size is set too large. + In particular, conformant SNMP implementations are not + required to accept messages whose length exceeds 484 + octets, although they are encouraged to support larger + datagrams whenever feasible." + DEFVAL { 100 } + ::= { bufferControlEntry 6 } + + bufferControlDownloadOffset OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The offset of the first octet of each packet + in this capture buffer that will be returned in + an SNMP retrieval of that packet. For example, + if 500 octets of a packet have been stored in the + associated capture buffer and this object is set to + 100, then the captureBufferPacket object that + contains the packet will contain bytes starting + 100 octets into the packet." + DEFVAL { 0 } + ::= { bufferControlEntry 7 } + + bufferControlMaxOctetsRequested OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The requested maximum number of octets to be + saved in this captureBuffer, including any + + + implementation-specific overhead. If this variable + is set to -1, the capture buffer will save as many + octets as is possible. + + When this object is created or modified, the probe + should set bufferControlMaxOctetsGranted as closely + to this object as is possible for the particular probe + implementation and available resources. However, if + the object has the special value of -1, the probe + must set bufferControlMaxOctetsGranted to -1." + DEFVAL { -1 } + ::= { bufferControlEntry 8 } + + bufferControlMaxOctetsGranted OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The maximum number of octets that can be + saved in this captureBuffer, including overhead. + If this variable is -1, the capture buffer will save + as many octets as possible. + + When the bufferControlMaxOctetsRequested object is + created or modified, the probe should set this object + as closely to the requested value as is possible for + the particular probe implementation and available + resources. However, if the request object has the + special value of -1, the probe must set this object + to -1. The probe must not lower this value except + as a result of a modification to the associated + bufferControlMaxOctetsRequested object. + + When this maximum number of octets is reached + and a new packet is to be added to this + capture buffer and the corresponding + bufferControlFullAction is set to wrapWhenFull(2), + enough of the oldest packets associated with this + capture buffer shall be deleted by the agent so + that the new packet can be added. If the + corresponding bufferControlFullAction is set to + lockWhenFull(1), the new packet shall be discarded. + In either case, the probe must set + bufferControlFullStatus to full(2). + + When the value of this object changes to a value less + than the current value, entries are deleted from + the captureBufferTable associated with this + + + bufferControlEntry. Enough of the + oldest of these captureBufferEntries shall be + deleted by the agent so that the number of octets + used remains less than or equal to the new value of + this object. + + When the value of this object changes to a value greater + than the current value, the number of associated + captureBufferEntries may be allowed to grow." + ::= { bufferControlEntry 9 } + + bufferControlCapturedPackets OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of packets currently in this captureBuffer." + ::= { bufferControlEntry 10 } + + bufferControlTurnOnTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime when this capture buffer was + first turned on." + ::= { bufferControlEntry 11 } + + bufferControlOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is therefore + using the resources assigned to it." + ::= { bufferControlEntry 12 } + + bufferControlStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this buffer Control Entry." + ::= { bufferControlEntry 13 } + + captureBufferTable OBJECT-TYPE + SYNTAX SEQUENCE OF CaptureBufferEntry + ACCESS not-accessible + + + STATUS mandatory + DESCRIPTION + "A list of packets captured off of a channel." + ::= { capture 2 } + + captureBufferEntry OBJECT-TYPE + SYNTAX CaptureBufferEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A packet captured off of an attached network." + INDEX { captureBufferControlIndex, captureBufferIndex } + ::= { captureBufferTable 1 } + + CaptureBufferEntry ::= SEQUENCE { + captureBufferControlIndex INTEGER (1..65535), + captureBufferIndex INTEGER, + captureBufferPacketID INTEGER, + captureBufferPacketData OCTET STRING, + captureBufferPacketLength INTEGER, + captureBufferPacketTime INTEGER, + captureBufferPacketStatus INTEGER + } + + captureBufferControlIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The index of the bufferControlEntry with which + this packet is associated." + ::= { captureBufferEntry 1 } + + captureBufferIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry + in the captureBuffer table associated with a + particular bufferControlEntry. This index will + start at 1 and increase by one for each new packet + added with the same captureBufferControlIndex." + ::= { captureBufferEntry 2 } + + captureBufferPacketID OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + + + STATUS mandatory + DESCRIPTION + "An index that describes the order of packets + that are received on a particular interface. + The packetID of a packet captured on an + interface is defined to be greater than the + packetID's of all packets captured previously on + the same interface. As the captureBufferPacketID + object has a maximum positive value of 2^31 - 1, + any captureBufferPacketID object shall have the + value of the associated packet's packetID mod 2^31." + ::= { captureBufferEntry 3 } + + captureBufferPacketData OBJECT-TYPE + SYNTAX OCTET STRING + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The data inside the packet, starting at the beginning + of the packet plus any offset specified in the + associated bufferControlDownloadOffset, including any + link level headers. The length of the data in this + object is the minimum of the length of the captured + packet minus the offset, the length of the associated + bufferControlCaptureSliceSize minus the offset, and the + associated bufferControlDownloadSliceSize. If this + minimum is less than zero, this object shall have a + length of zero." + ::= { captureBufferEntry 4 } + + captureBufferPacketLength OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The actual length (off the wire) of the packet stored + in this entry, including FCS octets." + ::= { captureBufferEntry 5 } + + captureBufferPacketTime OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The number of milliseconds that had passed since + this capture buffer was first turned on when this + packet was captured." + ::= { captureBufferEntry 6 } + + + captureBufferPacketStatus OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "A value which indicates the error status of this + packet. + + The value of this object is defined in the same way as + filterPacketStatus. The value is a sum. This sum + initially takes the value zero. Then, for each + error, E, that has been discovered in this packet, + 2 raised to a value representing E is added to the sum. + + The errors defined for a packet captured off of an + Ethernet interface are as follows: + + bit # Error + 0 Packet is longer than 1518 octets + 1 Packet is shorter than 64 octets + 2 Packet experienced a CRC or Alignment + error + 3 First packet in this capture buffer after + it was detected that some packets were + not processed correctly. + + For example, an Ethernet fragment would have a + value of 6 (2^1 + 2^2). + + As this MIB is expanded to new media types, this object + will have other media-specific errors defined." + ::= { captureBufferEntry 7 } + + + -- The Event Group + + -- Implementation of the Event group is optional. + -- + -- The Event group controls the generation and notification + -- of events from this device. Each entry in the eventTable + -- describes the parameters of the event that can be triggered. + -- Each event entry is fired by an associated condition located + -- elsewhere in the MIB. An event entry may also be associated + -- with a function elsewhere in the MIB that will be executed + -- when the event is generated. For example, a channel may + -- be turned on or off by the firing of an event. + -- + -- Each eventEntry may optionally specify that a log entry + + + -- be created on its behalf whenever the event occurs. + -- Each entry may also specify that notification should + -- occur by way of SNMP trap messages. In this case, the + -- community for the trap message is given in the associated + -- eventCommunity object. The enterprise and specific trap + -- fields of the trap are determined by the condition that + -- triggered the event. Three traps are defined in a companion + -- document: risingAlarm, fallingAlarm, and packetMatch. + -- If the eventTable is triggered by a condition specified + -- elsewhere, the enterprise and specific trap fields + -- must be specified for traps generated for that condition. + + eventTable OBJECT-TYPE + SYNTAX SEQUENCE OF EventEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of events to be generated." + ::= { event 1 } + + eventEntry OBJECT-TYPE + SYNTAX EventEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of parameters that describe an event to be + generated when certain conditions are met." + INDEX { eventIndex } + ::= { eventTable 1 } + + EventEntry ::= SEQUENCE { + eventIndex INTEGER (1..65535), + eventDescription DisplayString (SIZE (0..127)), + eventType INTEGER, + eventCommunity OCTET STRING (SIZE (0..127)), + eventLastTimeSent TimeTicks, + eventOwner OwnerString, + eventStatus INTEGER + } + + eventIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry in the + event table. Each such entry defines one event that + is to be generated when the appropriate conditions + + + occur." + ::= { eventEntry 1 } + + eventDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..127)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "A comment describing this event entry." + ::= { eventEntry 2 } + + eventType OBJECT-TYPE + SYNTAX INTEGER { + none(1), + log(2), + snmp-trap(3), -- send an SNMP trap + log-and-trap(4) + } + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The type of notification that the probe will make + about this event. In the case of log, an entry is + made in the log table for each event. In the case of + snmp-trap, an SNMP trap is sent to one or more + management stations." + ::= { eventEntry 3 } + + eventCommunity OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..127)) + ACCESS read-write + STATUS mandatory + DESCRIPTION + "If an SNMP trap is to be sent, it will be sent to + the SNMP community specified by this octet string. + In the future this table will be extended to include + the party security mechanism. This object shall be + set to a string of length zero if it is intended that + that mechanism be used to specify the destination of + the trap." + ::= { eventEntry 4 } + + eventLastTimeSent OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime at the time this event + + + entry last generated an event. If this entry has + not generated any events, this value will be + zero." + ::= { eventEntry 5 } + + eventOwner OBJECT-TYPE + SYNTAX OwnerString + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The entity that configured this entry and is therefore + using the resources assigned to it. + + If this object contains a string starting with 'monitor' + and has associated entries in the log table, all + connected management stations should retrieve those + log entries, as they may have significance to all + management stations connected to this device" + ::= { eventEntry 6 } + + eventStatus OBJECT-TYPE + SYNTAX EntryStatus + ACCESS read-write + STATUS mandatory + DESCRIPTION + "The status of this event entry. + + If this object is not equal to valid(1), all associated + log entries shall be deleted by the agent." + ::= { eventEntry 7 } + + -- + logTable OBJECT-TYPE + SYNTAX SEQUENCE OF LogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A list of events that have been logged." + ::= { event 2 } + + logEntry OBJECT-TYPE + SYNTAX LogEntry + ACCESS not-accessible + STATUS mandatory + DESCRIPTION + "A set of data describing an event that has been + logged." + INDEX { logEventIndex, logIndex } + + + ::= { logTable 1 } + + LogEntry ::= SEQUENCE { + logEventIndex INTEGER (1..65535), + logIndex INTEGER, + logTime TimeTicks, + logDescription DisplayString (SIZE (0..255)) + } + + logEventIndex OBJECT-TYPE + SYNTAX INTEGER (1..65535) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The event entry that generated this log + entry. The log identified by a particular + value of this index is associated with the same + eventEntry as identified by the same value + of eventIndex." + ::= { logEntry 1 } + + logIndex OBJECT-TYPE + SYNTAX INTEGER + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An index that uniquely identifies an entry + in the log table amongst those generated by the + same eventEntries. These indexes are + assigned beginning with 1 and increase by one + with each new log entry. The association + between values of logIndex and logEntries + is fixed for the lifetime of each logEntry. + The agent may choose to delete the oldest + instances of logEntry as required because of + lack of memory. It is an implementation-specific + matter as to when this deletion may occur." + ::= { logEntry 2 } + + logTime OBJECT-TYPE + SYNTAX TimeTicks + ACCESS read-only + STATUS mandatory + DESCRIPTION + "The value of sysUpTime when this log entry was + created." + ::= { logEntry 3 } + + + + logDescription OBJECT-TYPE + SYNTAX DisplayString (SIZE (0..255)) + ACCESS read-only + STATUS mandatory + DESCRIPTION + "An implementation dependent description of the + event that activated this log entry." + ::= { logEntry 4 } + + END + |