diff options
author | Micael Karlberg <[email protected]> | 2013-02-05 11:36:20 +0100 |
---|---|---|
committer | Micael Karlberg <[email protected]> | 2013-02-05 13:56:44 +0100 |
commit | 19bb4c1bc496ae36aa112f7137be5acf4dfd2c4f (patch) | |
tree | 2c658c04df804c6e73989c723ee5e8630307c343 /lib/snmp/test | |
parent | d9e63bfb1a4a452ad8eb7a9e62d5127a666e2845 (diff) | |
download | otp-19bb4c1bc496ae36aa112f7137be5acf4dfd2c4f.tar.gz otp-19bb4c1bc496ae36aa112f7137be5acf4dfd2c4f.tar.bz2 otp-19bb4c1bc496ae36aa112f7137be5acf4dfd2c4f.zip |
[snmp/compiler] Add the mib (ALARM-MIB)
Diffstat (limited to 'lib/snmp/test')
-rw-r--r-- | lib/snmp/test/test-mibs/ALARM-MIB.mib | 1214 |
1 files changed, 1214 insertions, 0 deletions
diff --git a/lib/snmp/test/test-mibs/ALARM-MIB.mib b/lib/snmp/test/test-mibs/ALARM-MIB.mib new file mode 100644 index 0000000000..18e43d4b4b --- /dev/null +++ b/lib/snmp/test/test-mibs/ALARM-MIB.mib @@ -0,0 +1,1214 @@ +ALARM-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, + Integer32, Unsigned32, Gauge32, + TimeTicks, Counter32, Counter64, + IpAddress, Opaque, mib-2, + zeroDotZero + FROM SNMPv2-SMI -- [RFC2578] + DateAndTime, + RowStatus, RowPointer, + TEXTUAL-CONVENTION + FROM SNMPv2-TC -- [RFC2579] + SnmpAdminString + FROM SNMP-FRAMEWORK-MIB -- [RFC3411] + InetAddressType, InetAddress + FROM INET-ADDRESS-MIB -- [RFC3291] + MODULE-COMPLIANCE, OBJECT-GROUP, + NOTIFICATION-GROUP + FROM SNMPv2-CONF -- [RFC2580] + ZeroBasedCounter32 + FROM RMON2-MIB; -- [RFC2021] + + alarmMIB MODULE-IDENTITY + LAST-UPDATED "200409090000Z" -- September 09, 2004 + ORGANIZATION "IETF Distributed Management Working Group" + CONTACT-INFO + "WG EMail: [email protected] + Subscribe: [email protected] + http://www.ietf.org/html.charters/disman-charter.html + + + + + Chair: Randy Presuhn + + Editors: Sharon Chisholm + Nortel Networks + PO Box 3511 Station C + Ottawa, Ont. K1Y 4H7 + Canada + + Dan Romascanu + Avaya + Atidim Technology Park, Bldg. #3 + Tel Aviv, 61131 + Israel + Tel: +972-3-645-8414 + Email: [email protected]" + DESCRIPTION + "The MIB module describes a generic solution + to model alarms and to store the current list + of active alarms. + + Copyright (C) The Internet Society (2004). The + initial version of this MIB module was published + in RFC 3877. For full legal notices see the RFC + itself. Supplementary information may be available on: + http://www.ietf.org/copyrights/ianamib.html" + REVISION "200409090000Z" -- September 09, 2004 + DESCRIPTION + "Initial version, published as RFC 3877." + ::= { mib-2 118 } + +alarmObjects OBJECT IDENTIFIER ::= { alarmMIB 1 } + +alarmNotifications OBJECT IDENTIFIER ::= { alarmMIB 0 } + +alarmModel OBJECT IDENTIFIER ::= { alarmObjects 1 } + +alarmActive OBJECT IDENTIFIER ::= { alarmObjects 2 } + +alarmClear OBJECT IDENTIFIER ::= { alarmObjects 3 } + +-- Textual Conventions + + -- ResourceId is intended to be a general textual convention + -- that can be used outside of the set of MIBs related to + -- Alarm Management. + + + + + +ResourceId ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "A unique identifier for this resource. + + The type of the resource can be determined by looking + at the OID that describes the resource. + + Resources must be identified in a consistent manner. + For example, if this resource is an interface, this + object MUST point to an ifIndex and if this resource + is a physical entity [RFC2737], then this MUST point + to an entPhysicalDescr, given that entPhysicalIndex + is not accessible. In general, the value is the + name of the instance of the first accessible columnar + object in the conceptual row of a table that is + meaningful for this resource type, which SHOULD + be defined in an IETF standard MIB." + SYNTAX OBJECT IDENTIFIER + + -- LocalSnmpEngineOrZeroLenStr is intended to be a general + -- textual convention that can be used outside of the set of + -- MIBs related to Alarm Management. + + LocalSnmpEngineOrZeroLenStr ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "An SNMP Engine ID or a zero-length string. The + instantiation of this textual convention will provide + guidance on when this will be an SNMP Engine ID and + when it will be a zero lengths string" + SYNTAX OCTET STRING (SIZE(0 | 5..32)) + +-- Alarm Model + +alarmModelLastChanged OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time of the last + creation, deletion or modification of an entry in + the alarmModelTable. + + If the number and content of entries has been unchanged + since the last re-initialization of the local network + management subsystem, then the value of this object + MUST be zero." + + + + + ::= { alarmModel 1 } + +alarmModelTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmModelEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of information about possible alarms on the system, + and how they have been modelled." + ::= { alarmModel 2 } + +alarmModelEntry OBJECT-TYPE + SYNTAX AlarmModelEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entries appear in this table for each possible alarm state. + This table MUST be persistent across system reboots." + INDEX { alarmListName, alarmModelIndex, alarmModelState } + ::= { alarmModelTable 1 } + +AlarmModelEntry ::= SEQUENCE { + alarmModelIndex Unsigned32, + alarmModelState Unsigned32, + alarmModelNotificationId OBJECT IDENTIFIER, + alarmModelVarbindIndex Unsigned32, + alarmModelVarbindValue Integer32, + alarmModelDescription SnmpAdminString, + alarmModelSpecificPointer RowPointer, + alarmModelVarbindSubtree OBJECT IDENTIFIER, + alarmModelResourcePrefix OBJECT IDENTIFIER, + alarmModelRowStatus RowStatus + } + +alarmModelIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An integer that acts as an alarm Id + to uniquely identify each alarm + within the named alarm list. " + ::= { alarmModelEntry 1 } + +alarmModelState OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS not-accessible + STATUS current + + + + + DESCRIPTION + "A value of 1 MUST indicate a clear alarm state. + The value of this object MUST be less than the + alarmModelState of more severe alarm states for + this alarm. The value of this object MUST be more + than the alarmModelState of less severe alarm states + for this alarm." + ::= { alarmModelEntry 2 } + +alarmModelNotificationId OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The NOTIFICATION-TYPE object identifier of this alarm + state transition. If there is no notification associated + with this alarm state, the value of this object MUST be + '0.0'" + DEFVAL { zeroDotZero } + ::= { alarmModelEntry 3 } + +alarmModelVarbindIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The index into the varbind listing of the notification + indicated by alarmModelNotificationId which helps + signal that the given alarm has changed state. + If there is no applicable varbind, the value of this + object MUST be zero. + + Note that the value of alarmModelVarbindIndex acknowledges + the existence of the first two obligatory varbinds in + the InformRequest-PDU and SNMPv2-Trap-PDU (sysUpTime.0 + and snmpTrapOID.0). That is, a value of 2 refers to + the snmpTrapOID.0. + + If the incoming notification is instead an SNMPv1 Trap-PDU, + then an appropriate value for sysUpTime.0 or snmpTrapOID.0 + shall be determined by using the rules in section 3.1 of + [RFC3584]" + DEFVAL { 0 } + ::= { alarmModelEntry 4 } + +alarmModelVarbindValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-create + + + + + STATUS current + DESCRIPTION + "The value that the varbind indicated by + alarmModelVarbindIndex takes to indicate + that the alarm has entered this state. + + If alarmModelVarbindIndex has a value of 0, so + MUST alarmModelVarbindValue. + " + DEFVAL { 0 } + ::= { alarmModelEntry 5 } + +alarmModelDescription OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A brief description of this alarm and state suitable + to display to operators." + DEFVAL { "" } + ::= { alarmModelEntry 6 } + +alarmModelSpecificPointer OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "If no additional, model-specific Alarm MIB is supported by + the system the value of this object is `0.0'and attempts + to set it to any other value MUST be rejected appropriately. + + When a model-specific Alarm MIB is supported, this object + MUST refer to the first accessible object in a corresponding + row of the model definition in one of these model-specific + MIB and attempts to set this object to { 0 0 } or any other + value MUST be rejected appropriately." + DEFVAL { zeroDotZero } + ::= { alarmModelEntry 7 } + + alarmModelVarbindSubtree OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The name portion of each VarBind in the notification, + in order, is compared to the value of this object. + If the name is equal to or a subtree of the value + of this object, for purposes of computing the value + + + + + of AlarmActiveResourceID the 'prefix' will be the + matching portion, and the 'indexes' will be any + remainder. The examination of varbinds ends with + the first match. If the value of this object is 0.0, + then the first varbind, or in the case of v2, the + first varbind after the timestamp and the trap + OID, will always be matched. + " + DEFVAL { zeroDotZero } + ::= { alarmModelEntry 8 } + + alarmModelResourcePrefix OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The value of AlarmActiveResourceId is computed + by appending any indexes extracted in accordance + with the description of alarmModelVarbindSubtree + onto the value of this object. If this object's + value is 0.0, then the 'prefix' extracted is used + instead. + " + DEFVAL { zeroDotZero } + ::= { alarmModelEntry 9 } + +alarmModelRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Control for creating and deleting entries. Entries may be + modified while active. Alarms whose alarmModelRowStatus is + not active will not appear in either the alarmActiveTable + or the alarmClearTable. Setting this object to notInService + cannot be used as an alarm suppression mechanism. Entries + that are notInService will disappear as described in RFC2579. + + This row can not be modified while it is being + referenced by a value of alarmActiveModelPointer. In these + cases, an error of `inconsistentValue' will be returned to + the manager. + + This entry may be deleted while it is being + referenced by a value of alarmActiveModelPointer. This results + in the deletion of this entry and entries in the active alarms + referencing this entry via an alarmActiveModelPointer. + + + + + + As all read-create objects in this table have a DEFVAL clause, + there is no requirement that any object be explicitly set + before this row can become active. Note that a row consisting + only of default values is not very meaningful." + ::= { alarmModelEntry 10 } + +-- Active Alarm Table -- + +alarmActiveLastChanged OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time of the last + creation or deletion of an entry in the alarmActiveTable. + If the number of entries has been unchanged since the + last re-initialization of the local network management + subsystem, then this object contains a zero value." + ::= { alarmActive 1 } + + alarmActiveOverflow OBJECT-TYPE + SYNTAX Counter32 + UNITS "active alarms" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of active alarms that have not been put into + the alarmActiveTable since system restart as a result + of extreme resource constraints." + ::= { alarmActive 5 } + +alarmActiveTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmActiveEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of Active Alarms entries." + ::= { alarmActive 2 } + +alarmActiveEntry OBJECT-TYPE + SYNTAX AlarmActiveEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entries appear in this table when alarms are raised. They + are removed when the alarm is cleared. + + If under extreme resource constraint the system is unable to + + + + + add any more entries into this table, then the + alarmActiveOverflow statistic will be increased by one." + INDEX { alarmListName, alarmActiveDateAndTime, + alarmActiveIndex } + ::= { alarmActiveTable 1 } + +AlarmActiveEntry ::= SEQUENCE { + alarmListName SnmpAdminString, + alarmActiveDateAndTime DateAndTime, + alarmActiveIndex Unsigned32, + alarmActiveEngineID LocalSnmpEngineOrZeroLenStr, + alarmActiveEngineAddressType InetAddressType, + alarmActiveEngineAddress InetAddress, + alarmActiveContextName SnmpAdminString, + alarmActiveVariables Unsigned32, + alarmActiveNotificationID OBJECT IDENTIFIER, + alarmActiveResourceId ResourceId, + alarmActiveDescription SnmpAdminString, + alarmActiveLogPointer RowPointer, + alarmActiveModelPointer RowPointer, + alarmActiveSpecificPointer RowPointer } + +alarmListName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE(0..32)) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The name of the list of alarms. This SHOULD be the same as + nlmLogName if the Notification Log MIB [RFC3014] is supported. + This SHOULD be the same as, or contain as a prefix, the + applicable snmpNotifyFilterProfileName if the + SNMP-NOTIFICATION-MIB DEFINITIONS [RFC3413] is supported. + + An implementation may allow multiple named alarm lists, up to + some implementation-specific limit (which may be none). A + zero-length list name is reserved for creation and deletion + by the managed system, and MUST be used as the default log + name by systems that do not support named alarm lists." + ::= { alarmActiveEntry 1 } + +alarmActiveDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The local date and time when the error occurred. + + This object facilitates retrieving all instances of + + + + + alarms that have been raised or have changed state + since a given point in time. + + Implementations MUST include the offset from UTC, + if available. Implementation in environments in which + the UTC offset is not available is NOT RECOMMENDED." + ::= { alarmActiveEntry 2 } + +alarmActiveIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A strictly monotonically increasing integer which + acts as the index of entries within the named alarm + list. It wraps back to 1 after it reaches its + maximum value." + ::= { alarmActiveEntry 3 } + +alarmActiveEngineID OBJECT-TYPE + SYNTAX LocalSnmpEngineOrZeroLenStr + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The identification of the SNMP engine at which the alarm + originated. If the alarm is from an SNMPv1 system this + object is a zero length string." + ::= { alarmActiveEntry 4 } + +alarmActiveEngineAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates what type of address is stored in + the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc." + ::= { alarmActiveEntry 5 } + +alarmActiveEngineAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The address of the SNMP engine on which the alarm is + occurring. + + This object MUST always be instantiated, even if the list + can contain alarms from only one engine." + + + + + ::= { alarmActiveEntry 6 } + +alarmActiveContextName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the SNMP MIB context from which the alarm came. + For SNMPv1 alarms this is the community string from the Trap. + Note that care MUST be taken when selecting community + strings to ensure that these can be represented as a + well-formed SnmpAdminString. Community or Context names + that are not well-formed SnmpAdminStrings will be mapped + to zero length strings. + + If the alarm's source SNMP engine is known not to support + multiple contexts, this object is a zero length string." + ::= { alarmActiveEntry 7 } + +alarmActiveVariables OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of variables in alarmActiveVariableTable for this + alarm." + ::= { alarmActiveEntry 8 } + +alarmActiveNotificationID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The NOTIFICATION-TYPE object identifier of the alarm + state transition that is occurring." + ::= { alarmActiveEntry 9 } + +alarmActiveResourceId OBJECT-TYPE + SYNTAX ResourceId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the resource under alarm. + + If there is no corresponding resource, then + the value of this object MUST be 0.0." + ::= { alarmActiveEntry 10 } + + + + + +alarmActiveDescription OBJECT-TYPE + SYNTAX SnmpAdminString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object provides a textual description of the + active alarm. This text is generated dynamically by the + notification generator to provide useful information + to the human operator. This information SHOULD + provide information allowing the operator to locate + the resource for which this alarm is being generated. + This information is not intended for consumption by + automated tools." + ::= { alarmActiveEntry 11 } + +alarmActiveLogPointer OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A pointer to the corresponding row in a + notification logging MIB where the state change + notification for this active alarm is logged. + If no log entry applies to this active alarm, + then this object MUST have the value of 0.0" + ::= { alarmActiveEntry 12 } + +alarmActiveModelPointer OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A pointer to the corresponding row in the + alarmModelTable for this active alarm. This + points not only to the alarm model being + instantiated, but also to the specific alarm + state that is active." + ::= { alarmActiveEntry 13 } + +alarmActiveSpecificPointer OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "If no additional, model-specific, Alarm MIB is supported by + the system this object is `0.0'. When a model-specific Alarm + MIB is supported, this object is the instance pointer to the + specific model-specific active alarm list." + + + + + ::= { alarmActiveEntry 14 } + +-- Active Alarm Variable Table -- + +alarmActiveVariableTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmActiveVariableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of variables to go with active alarm entries." + ::= { alarmActive 3 } + +alarmActiveVariableEntry OBJECT-TYPE + SYNTAX AlarmActiveVariableEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entries appear in this table when there are variables in + the varbind list of a corresponding alarm in + alarmActiveTable. + + Entries appear in this table as though + the trap/notification had been transported using a + SNMPv2-Trap-PDU, as defined in [RFC3416] - i.e., the + alarmActiveVariableIndex 1 will always be sysUpTime + and alarmActiveVariableIndex 2 will always be + snmpTrapOID. + + If the incoming notification is instead an SNMPv1 Trap-PDU and + the value of alarmModelVarbindIndex is 1 or 2, an appropriate + value for sysUpTime.0 or snmpTrapOID.0 shall be determined + by using the rules in section 3.1 of [RFC3584]." + INDEX { alarmListName, alarmActiveIndex, + alarmActiveVariableIndex } + ::= { alarmActiveVariableTable 1 } + +AlarmActiveVariableEntry ::= SEQUENCE { + alarmActiveVariableIndex Unsigned32, + alarmActiveVariableID OBJECT IDENTIFIER, + alarmActiveVariableValueType INTEGER, + alarmActiveVariableCounter32Val Counter32, + alarmActiveVariableUnsigned32Val Unsigned32, + alarmActiveVariableTimeTicksVal TimeTicks, + alarmActiveVariableInteger32Val Integer32, + alarmActiveVariableOctetStringVal OCTET STRING, + alarmActiveVariableIpAddressVal IpAddress, + alarmActiveVariableOidVal OBJECT IDENTIFIER, + alarmActiveVariableCounter64Val Counter64, + + + + + alarmActiveVariableOpaqueVal Opaque } + +alarmActiveVariableIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A strictly monotonically increasing integer, starting at + 1 for a given alarmActiveIndex, for indexing variables + within the active alarm variable list. " + ::= { alarmActiveVariableEntry 1 } + +alarmActiveVariableID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The alarm variable's object identifier." + ::= { alarmActiveVariableEntry 2 } + +alarmActiveVariableValueType OBJECT-TYPE + SYNTAX INTEGER { + counter32(1), + unsigned32(2), + timeTicks(3), + integer32(4), + ipAddress(5), + octetString(6), + objectId(7), + counter64(8), + opaque(9) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of the value. One and only one of the value + objects that follow is used for a given row in this table, + based on this type." + ::= { alarmActiveVariableEntry 3 } + +alarmActiveVariableCounter32Val OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'counter32'." + ::= { alarmActiveVariableEntry 4 } + + + + + +alarmActiveVariableUnsigned32Val OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'unsigned32'." + ::= { alarmActiveVariableEntry 5 } + +alarmActiveVariableTimeTicksVal OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'timeTicks'." + ::= { alarmActiveVariableEntry 6 } + +alarmActiveVariableInteger32Val OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'integer32'." + ::= { alarmActiveVariableEntry 7 } + +alarmActiveVariableOctetStringVal OBJECT-TYPE + SYNTAX OCTET STRING (SIZE(0..65535)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'octetString'." + ::= { alarmActiveVariableEntry 8 } + +alarmActiveVariableIpAddressVal OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'ipAddress'." + ::= { alarmActiveVariableEntry 9 } + +alarmActiveVariableOidVal OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'objectId'." + ::= { alarmActiveVariableEntry 10 } + + + + + +alarmActiveVariableCounter64Val OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'counter64'." + ::= { alarmActiveVariableEntry 11 } + +alarmActiveVariableOpaqueVal OBJECT-TYPE + SYNTAX Opaque + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value when alarmActiveVariableType is 'opaque'. + + Note that although RFC2578 [RFC2578] forbids the use + of Opaque in 'standard' MIB modules, this particular + usage is driven by the need to be able to accurately + represent any well-formed notification, and justified + by the need for backward compatibility." + ::= { alarmActiveVariableEntry 12 } + +-- Statistics -- + +alarmActiveStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmActiveStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table represents the alarm statistics + information." + ::= { alarmActive 4 } + +alarmActiveStatsEntry OBJECT-TYPE + SYNTAX AlarmActiveStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Statistics on the current active alarms." + INDEX { alarmListName } + + ::= { alarmActiveStatsTable 1 } + +AlarmActiveStatsEntry ::= + SEQUENCE { + alarmActiveStatsActiveCurrent Gauge32, + alarmActiveStatsActives ZeroBasedCounter32, + alarmActiveStatsLastRaise TimeTicks, + + + + + alarmActiveStatsLastClear TimeTicks + } + +alarmActiveStatsActiveCurrent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of currently active alarms on the system." + ::= { alarmActiveStatsEntry 1 } + +alarmActiveStatsActives OBJECT-TYPE + SYNTAX ZeroBasedCounter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of active alarms since system restarted." + ::= { alarmActiveStatsEntry 2 } + +alarmActiveStatsLastRaise OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time of the last + alarm raise for this alarm list. + If no alarm raises have occurred since the + last re-initialization of the local network management + subsystem, then this object contains a zero value." + ::= { alarmActiveStatsEntry 3 } + +alarmActiveStatsLastClear OBJECT-TYPE + SYNTAX TimeTicks + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The value of sysUpTime at the time of the last + alarm clear for this alarm list. + If no alarm clears have occurred since the + last re-initialization of the local network management + subsystem, then this object contains a zero value." + ::= { alarmActiveStatsEntry 4 } + +-- Alarm Clear + +alarmClearMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + + + + + STATUS current + DESCRIPTION + "This object specifies the maximum number of cleared + alarms to store in the alarmClearTable. When this + number is reached, the cleared alarms with the + earliest clear time will be removed from the table." + ::= { alarmClear 1 } + +alarmClearTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmClearEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains information on + cleared alarms." + ::= { alarmClear 2 } + +alarmClearEntry OBJECT-TYPE + SYNTAX AlarmClearEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Information on a cleared alarm." + INDEX { alarmListName, alarmClearDateAndTime, +alarmClearIndex } + + ::= { alarmClearTable 1 } + +AlarmClearEntry ::= + SEQUENCE { + alarmClearIndex Unsigned32, + alarmClearDateAndTime DateAndTime, + alarmClearEngineID LocalSnmpEngineOrZeroLenStr, + alarmClearEngineAddressType InetAddressType, + alarmClearEngineAddress InetAddress, + alarmClearContextName SnmpAdminString, + alarmClearNotificationID OBJECT IDENTIFIER, + alarmClearResourceId ResourceId, + alarmClearLogIndex Unsigned32, + alarmClearModelPointer RowPointer + } + +alarmClearIndex OBJECT-TYPE + SYNTAX Unsigned32 (1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An integer which acts as the index of entries within + + + + + the named alarm list. It wraps back to 1 after it + reaches its maximum value. + + This object has the same value as the alarmActiveIndex that + this alarm instance had when it was active." + ::= { alarmClearEntry 1 } + +alarmClearDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The local date and time when the alarm cleared. + + This object facilitates retrieving all instances of + alarms that have been cleared since a given point in time. + + Implementations MUST include the offset from UTC, + if available. Implementation in environments in which + the UTC offset is not available is NOT RECOMMENDED." + ::= { alarmClearEntry 2 } + +alarmClearEngineID OBJECT-TYPE + SYNTAX LocalSnmpEngineOrZeroLenStr + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The identification of the SNMP engine at which the alarm + originated. If the alarm is from an SNMPv1 system this + object is a zero length string." + ::= { alarmClearEntry 3 } + +alarmClearEngineAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates what type of address is stored in + the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc." + ::= { alarmClearEntry 4 } + +alarmClearEngineAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The Address of the SNMP engine on which the alarm was + occurring. This is used to identify the source of an SNMPv1 + + + + + trap, since an alarmActiveEngineId cannot be extracted from the + SNMPv1 trap PDU. + + This object MUST always be instantiated, even if the list + can contain alarms from only one engine." + ::= { alarmClearEntry 5 } + +alarmClearContextName OBJECT-TYPE + SYNTAX SnmpAdminString (SIZE(0..32)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The name of the SNMP MIB context from which the alarm came. + For SNMPv1 traps this is the community string from the Trap. + Note that care needs to be taken when selecting community + strings to ensure that these can be represented as a + well-formed SnmpAdminString. Community or Context names + that are not well-formed SnmpAdminStrings will be mapped + to zero length strings. + + If the alarm's source SNMP engine is known not to support + multiple contexts, this object is a zero length string." + ::= { alarmClearEntry 6 } + +alarmClearNotificationID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The NOTIFICATION-TYPE object identifier of the alarm + clear." + ::= { alarmClearEntry 7 } + +alarmClearResourceId OBJECT-TYPE + SYNTAX ResourceId + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object identifies the resource that was under alarm. + + If there is no corresponding resource, then + the value of this object MUST be 0.0." + ::= { alarmClearEntry 8 } + +alarmClearLogIndex OBJECT-TYPE + SYNTAX Unsigned32 (0..4294967295) + MAX-ACCESS read-only + STATUS current + + + + + DESCRIPTION + "This number MUST be the same as the log index of the + applicable row in the notification log MIB, if it exists. + If no log index applies to the trap, then this object + MUST have the value of 0." + ::= { alarmClearEntry 9 } + +alarmClearModelPointer OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A pointer to the corresponding row in the + alarmModelTable for this cleared alarm." + ::= { alarmClearEntry 10 } + +-- Notifications + +alarmActiveState NOTIFICATION-TYPE + OBJECTS { alarmActiveModelPointer, + alarmActiveResourceId } + STATUS current + DESCRIPTION + "An instance of the alarm indicated by + alarmActiveModelPointer has been raised + against the entity indicated by + alarmActiveResourceId. + + The agent must throttle the generation of + consecutive alarmActiveState traps so that there is at + least a two-second gap between traps of this + type against the same alarmActiveModelPointer and + alarmActiveResourceId. When traps are throttled, + they are dropped, not queued for sending at a future time. + + A management application should periodically check + the value of alarmActiveLastChanged to detect any + missed alarmActiveState notification-events, e.g., + due to throttling or transmission loss." + ::= { alarmNotifications 2 } + +alarmClearState NOTIFICATION-TYPE + OBJECTS { alarmActiveModelPointer, + alarmActiveResourceId } + STATUS current + DESCRIPTION + "An instance of the alarm indicated by + alarmActiveModelPointer has been cleared against + + + + + the entity indicated by alarmActiveResourceId. + + The agent must throttle the generation of + consecutive alarmActiveClear traps so that there is at + least a two-second gap between traps of this + type against the same alarmActiveModelPointer and + alarmActiveResourceId. When traps are throttled, + they are dropped, not queued for sending at a future time. + + A management application should periodically check + the value of alarmActiveLastChanged to detect any + missed alarmClearState notification-events, e.g., + due to throttling or transmission loss." + ::= { alarmNotifications 3 } + +-- Conformance + +alarmConformance OBJECT IDENTIFIER ::= { alarmMIB 2 } + +alarmCompliances OBJECT IDENTIFIER ::= { alarmConformance 1 } + +alarmCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for systems supporting + the Alarm MIB." + MODULE -- this module + MANDATORY-GROUPS { + alarmActiveGroup, + alarmModelGroup + } + GROUP alarmActiveStatsGroup + DESCRIPTION + "This group is optional." + GROUP alarmClearGroup + DESCRIPTION + "This group is optional." + GROUP alarmNotificationsGroup + DESCRIPTION + "This group is optional." + ::= { alarmCompliances 1 } + +alarmGroups OBJECT IDENTIFIER ::= { alarmConformance 2 } + +alarmModelGroup OBJECT-GROUP + OBJECTS { + alarmModelLastChanged, + alarmModelNotificationId, + + + + + alarmModelVarbindIndex, + alarmModelVarbindValue, + alarmModelDescription, + alarmModelSpecificPointer, + alarmModelVarbindSubtree, + alarmModelResourcePrefix, + alarmModelRowStatus + } + STATUS current + DESCRIPTION + "Alarm model group." + ::= { alarmGroups 1} + +alarmActiveGroup OBJECT-GROUP + OBJECTS { + alarmActiveLastChanged, + alarmActiveOverflow, + alarmActiveEngineID, + alarmActiveEngineAddressType, + alarmActiveEngineAddress, + alarmActiveContextName, + alarmActiveVariables, + alarmActiveNotificationID, + alarmActiveResourceId, + alarmActiveDescription, + alarmActiveLogPointer, + alarmActiveModelPointer, + alarmActiveSpecificPointer, + alarmActiveVariableID, + alarmActiveVariableValueType, + alarmActiveVariableCounter32Val, + alarmActiveVariableUnsigned32Val, + alarmActiveVariableTimeTicksVal, + alarmActiveVariableInteger32Val, + alarmActiveVariableOctetStringVal, + alarmActiveVariableIpAddressVal, + alarmActiveVariableOidVal, + alarmActiveVariableCounter64Val, + alarmActiveVariableOpaqueVal + } + STATUS current + DESCRIPTION + "Active Alarm list group." + ::= { alarmGroups 2} + + alarmActiveStatsGroup OBJECT-GROUP + OBJECTS { + alarmActiveStatsActives, + + + + + alarmActiveStatsActiveCurrent, + alarmActiveStatsLastRaise, + alarmActiveStatsLastClear + } + STATUS current + DESCRIPTION + "Active alarm summary group." + ::= { alarmGroups 3} + +alarmClearGroup OBJECT-GROUP + OBJECTS { + alarmClearMaximum, + alarmClearEngineID, + alarmClearEngineAddressType, + alarmClearEngineAddress, + alarmClearContextName, + alarmClearNotificationID, + alarmClearResourceId, + alarmClearLogIndex, + alarmClearModelPointer + } + STATUS current + DESCRIPTION + "Cleared alarm group." + ::= { alarmGroups 4} + +alarmNotificationsGroup NOTIFICATION-GROUP + NOTIFICATIONS { alarmActiveState, alarmClearState } + STATUS current + DESCRIPTION + "The collection of notifications that can be used to + model alarms for faults lacking pre-existing + notification definitions." + ::= { alarmGroups 6 } + +END |