aboutsummaryrefslogtreecommitdiffstats
path: root/lib/sasl/doc
diff options
context:
space:
mode:
Diffstat (limited to 'lib/sasl/doc')
-rw-r--r--lib/sasl/doc/src/alarm_handler.xml12
-rw-r--r--lib/sasl/doc/src/appup.xml23
-rw-r--r--lib/sasl/doc/src/notes.xml78
3 files changed, 106 insertions, 7 deletions
diff --git a/lib/sasl/doc/src/alarm_handler.xml b/lib/sasl/doc/src/alarm_handler.xml
index ab3041137e..e4def7c7f5 100644
--- a/lib/sasl/doc/src/alarm_handler.xml
+++ b/lib/sasl/doc/src/alarm_handler.xml
@@ -5,7 +5,7 @@
<header>
<copyright>
<year>1996</year>
- <year>2013</year>
+ <year>2014</year>
<holder>Ericsson AB, All Rights Reserved</holder>
</copyright>
<legalnotice>
@@ -87,7 +87,9 @@
<v>AlarmId = term()</v>
</type>
<desc>
- <p>Clears all alarms with id <c>AlarmId</c>.
+ <p>Sends the <c>clear_alarm</c> event to all event handlers.</p>
+ <p>When receiving this event, the default simple handler
+ clears the latest received alarm with id <c>AlarmId</c>.
</p>
</desc>
</func>
@@ -109,8 +111,10 @@
<v>AlarmDescription = term()</v>
</type>
<desc>
- <p>Sets an alarm with id <c>AlarmId</c>. This id is used at a
- later stage when the alarm is cleared.
+ <p>Sends the <c>set_alarm</c> event to all event handlers.</p>
+ <p>When receiving this event, the default simple handler
+ stores the alarm. The <c>AlarmId</c> identifies the alarm
+ and is used when the alarm is cleared.
</p>
</desc>
</func>
diff --git a/lib/sasl/doc/src/appup.xml b/lib/sasl/doc/src/appup.xml
index 85fcbed3ba..95f315d269 100644
--- a/lib/sasl/doc/src/appup.xml
+++ b/lib/sasl/doc/src/appup.xml
@@ -4,7 +4,7 @@
<fileref>
<header>
<copyright>
- <year>1997</year><year>2013</year>
+ <year>1997</year><year>2014</year>
<holder>Ericsson AB. All Rights Reserved.</holder>
</copyright>
<legalnotice>
@@ -84,6 +84,9 @@
version identifier must be specified as a binary, e.g.</p>
<code type="none">&lt;&lt;"2\\.1\\.[0-9]+">></code>
<p>will match all versions <c>2.1.x</c>, where x is any number.</p>
+ <p>Note that the regular expression must match the complete
+ version string, so the above example will work for for
+ e.g. <c>2.1.1</c>, but not for <c>2.1.1.1</c></p>
</section>
<section>
@@ -339,7 +342,7 @@ restart_new_emulator
version of erts, kernel, stdlib and sasl are used when the
emulator restarts. Only one <c>restart_new_emulator</c>
instruction is allowed in the relup, and it shall be placed
- first. <seealso marker="systools#make_relup/3">systools:make_relup3,4</seealso>
+ first. <seealso marker="systools#make_relup/3">systools:make_relup/3,4</seealso>
will ensure this when the relup is generated. The rest of the
relup script is executed after the restart as a part of the boot
script.</p>
@@ -347,11 +350,25 @@ restart_new_emulator
completed. To programatically find out if the upgrade is
complete,
call <seealso marker="release_handler#which_releases/0">
- release_handler:which_releases</seealso> and check if the
+ release_handler:which_releases/0,1</seealso> and check if the
expected release has status <c>current</c>.</p>
<p>The new release must still be made permanent after the upgrade
is completed. Otherwise, the old emulator is started in case of
an emulator restart.</p>
+ <warning>
+ <p>As stated above, the <c>restart_new_emulator</c>
+ instruction causes the emulator to be restarted with new
+ versions of <c>erts</c>, <c>kernel</c>, <c>stdlib</c> and
+ <c>sasl</c>. All other applications, however, will at startup
+ be running their old versions in this new emulator. In most
+ cases this is no problem, but every now and then there will be
+ incompatible changes to the core applications which may cause
+ trouble in this setting. Such incompatible changes (when
+ functions are removed) are normally preceded by a deprecation
+ over two major releases. To make sure your application is not
+ crashed by an incompatible change, always remove any call to
+ deprecated functions as soon as possible.</p>
+ </warning>
<pre>
restart_emulator
</pre>
diff --git a/lib/sasl/doc/src/notes.xml b/lib/sasl/doc/src/notes.xml
index 09d97cbe7b..95d7c6fa50 100644
--- a/lib/sasl/doc/src/notes.xml
+++ b/lib/sasl/doc/src/notes.xml
@@ -30,6 +30,84 @@
</header>
<p>This document describes the changes made to the SASL application.</p>
+<section><title>SASL 2.4.1</title>
+
+ <section><title>Fixed Bugs and Malfunctions</title>
+ <list>
+ <item>
+ <p>
+ The documentation erroneously specified that
+ <c>alarm_handler:clear_alarm/1</c> would clear
+ <em>all</em> alarms with id <c>AlarmId</c>. This is now
+ corrected according to the implementation - only the
+ latest received alarm with the given <c>AlarmId</c> is
+ cleared by the simple default handler.</p>
+ <p>
+ Own Id: OTP-12025</p>
+ </item>
+ </list>
+ </section>
+
+</section>
+
+<section><title>SASL 2.4</title>
+
+ <section><title>Fixed Bugs and Malfunctions</title>
+ <list>
+ <item>
+ <p>
+ The upgrade instruction 'restart_application' would
+ earlier ignore the restart type configured in the .rel
+ file and always restart the application as permanent.
+ This is now changed, and the restart type from the .rel
+ file is used. If restart type is 'load', the application
+ will only be loaded and not started. If the restart type
+ is 'none', the application will not be loaded nor
+ started, but all modules in the application will be
+ loaded. (Thanks to Tobias Schlager for reporting this
+ problem)</p>
+ <p>
+ *** POTENTIAL INCOMPATIBILITY ***</p>
+ <p>
+ Own Id: OTP-11716</p>
+ </item>
+ <item>
+ <p>
+ If <c>systools:make_script/2</c> failed with reason
+ <c>duplicate_modules</c>, and the <c>silent</c> flag was
+ not used, a crash with reason <c>function_clause</c>
+ would occur when <c>systools</c> tried to format the
+ error message. This has been corrected. (Thanks to
+ Jean-Sébastien Pédron)</p>
+ <p>
+ Own Id: OTP-11819</p>
+ </item>
+ </list>
+ </section>
+
+
+ <section><title>Improvements and New Features</title>
+ <list>
+ <item>
+ <p>
+ Calls to erlang:open_port/2 with 'spawn' are updated to
+ handle space in the command path.</p>
+ <p>
+ Own Id: OTP-10842</p>
+ </item>
+ <item>
+ <p>
+ Some more documentation is added to explain the behavior
+ when an upgrade includes new versions of ERTS, Kernel,
+ STDLIB or SASL.</p>
+ <p>
+ Own Id: OTP-11717</p>
+ </item>
+ </list>
+ </section>
+
+</section>
+
<section><title>SASL 2.3.4</title>
<section><title>Fixed Bugs and Malfunctions</title>