aboutsummaryrefslogtreecommitdiffstats
path: root/lib/snmp/test/test-mibs/RFC1271-MIB.mib
diff options
context:
space:
mode:
Diffstat (limited to 'lib/snmp/test/test-mibs/RFC1271-MIB.mib')
-rw-r--r--lib/snmp/test/test-mibs/RFC1271-MIB.mib3492
1 files changed, 3492 insertions, 0 deletions
diff --git a/lib/snmp/test/test-mibs/RFC1271-MIB.mib b/lib/snmp/test/test-mibs/RFC1271-MIB.mib
new file mode 100644
index 0000000000..25778dede8
--- /dev/null
+++ b/lib/snmp/test/test-mibs/RFC1271-MIB.mib
@@ -0,0 +1,3492 @@
+ RFC1271-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ Counter FROM RFC1155-SMI
+ mib-2,DisplayString FROM RFC1213-MIB
+ OBJECT-TYPE FROM RFC-1212;
+
+ -- This MIB module uses the extended OBJECT-TYPE macro as
+ -- defined in [9].
+
+
+ -- Remote Network Monitoring MIB
+
+ rmon OBJECT IDENTIFIER ::= { mib-2 16 }
+
+
+ -- textual conventions
+
+ OwnerString ::= DisplayString
+ -- This data type is used to model an administratively
+ -- assigned name of the owner of a resource. This
+ -- information is taken from the NVT ASCII character set.
+ -- It is suggested that this name contain one or more
+ -- of the following:
+ -- IP address, management station name, network manager's
+ -- name, location, or phone number.
+ -- In some cases the agent itself will be the owner of
+ -- an entry. In these cases, this string shall be set
+ -- to a string starting with 'monitor'.
+
+
+ --
+ -- SNMP access control is articulated entirely in terms of
+ -- the contents of MIB views; access to a particular SNMP
+ -- object instance depends only upon its presence or
+ -- absence in a particular MIB view and never upon its
+ -- value or the value of related object instances. Thus,
+ -- objects of this type afford resolution of resource
+ -- contention only among cooperating managers; they
+ -- realize no access control function with respect
+ -- to uncooperative parties.
+ --
+ -- By convention, objects with this syntax are declared
+ -- as having
+ --
+ -- SIZE (0..127)
+
+
+ EntryStatus ::= INTEGER
+ { valid(1),
+ createRequest(2),
+ underCreation(3),
+ invalid(4)
+ }
+
+ -- The status of a table entry.
+ --
+ -- Setting this object to the value invalid(4) has the
+ -- effect of invalidating the corresponding entry.
+ -- That is, it effectively disassociates the mapping
+ -- identified with said entry.
+ -- It is an implementation-specific matter as to whether
+ -- the agent removes an invalidated entry from the table.
+ -- Accordingly, management stations must be prepared to
+ -- receive tabular information from agents that corresponds
+ -- to entries currently not in use. Proper
+ -- interpretation of such entries requires examination
+ -- of the relevant EntryStatus object.
+ --
+ -- An existing instance of this object cannot be set to
+ -- createRequest(2). This object may only be set to
+ -- createRequest(2) when this instance is created. When
+ -- this object is created, the agent may wish to create
+ -- supplemental object instances to complete a conceptual
+ -- row in this table. Immediately after completing the
+ -- create operation, the agent must set this object to
+ -- underCreation(3).
+ --
+ -- Entries shall exist in the underCreation(3) state until
+
+
+ -- the management station is finished configuring the
+ -- entry and sets this object to valid(1) or aborts,
+ -- setting this object to invalid(4). If the agent
+ -- determines that an entry has been in the
+ -- underCreation(3) state for an abnormally long time,
+ -- it may decide that the management station has
+ -- crashed. If the agent makes this decision,
+ -- it may set this object to invalid(4) to reclaim the
+ -- entry. A prudent agent will understand that the
+ -- management station may need to wait for human input
+ -- and will allow for that possibility in its
+ -- determination of this abnormally long period.
+
+
+ statistics OBJECT IDENTIFIER ::= { rmon 1 }
+ history OBJECT IDENTIFIER ::= { rmon 2 }
+ alarm OBJECT IDENTIFIER ::= { rmon 3 }
+ hosts OBJECT IDENTIFIER ::= { rmon 4 }
+ hostTopN OBJECT IDENTIFIER ::= { rmon 5 }
+ matrix OBJECT IDENTIFIER ::= { rmon 6 }
+ filter OBJECT IDENTIFIER ::= { rmon 7 }
+ capture OBJECT IDENTIFIER ::= { rmon 8 }
+ event OBJECT IDENTIFIER ::= { rmon 9 }
+
+
+ -- The Statistics Group
+ --
+ -- Implementation of the Statistics group is optional.
+ --
+ -- The statistics group contains statistics measured by the
+ -- probe for each monitored interface on this device. These
+ -- statistics take the form of free running counters that
+ -- start from zero when a valid entry is created.
+ --
+ -- This group currently has statistics defined only for
+ -- Ethernet interfaces. Each etherStatsEntry contains
+ -- statistics for one Ethernet interface. The probe must
+ -- create one etherStats entry for each monitored Ethernet
+ -- interface on the device.
+
+ etherStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EtherStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of Ethernet statistics entries."
+ ::= { statistics 1 }
+
+
+
+ etherStatsEntry OBJECT-TYPE
+ SYNTAX EtherStatsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A collection of statistics kept for a particular
+ Ethernet interface."
+ INDEX { etherStatsIndex }
+ ::= { etherStatsTable 1 }
+
+ EtherStatsEntry ::= SEQUENCE {
+ etherStatsIndex INTEGER (1..65535),
+ etherStatsDataSource OBJECT IDENTIFIER,
+ etherStatsDropEvents Counter,
+ etherStatsOctets Counter,
+ etherStatsPkts Counter,
+ etherStatsBroadcastPkts Counter,
+ etherStatsMulticastPkts Counter,
+ etherStatsCRCAlignErrors Counter,
+ etherStatsUndersizePkts Counter,
+ etherStatsOversizePkts Counter,
+ etherStatsFragments Counter,
+ etherStatsJabbers Counter,
+ etherStatsCollisions Counter,
+ etherStatsPkts64Octets Counter,
+ etherStatsPkts65to127Octets Counter,
+ etherStatsPkts128to255Octets Counter,
+ etherStatsPkts256to511Octets Counter,
+ etherStatsPkts512to1023Octets Counter,
+ etherStatsPkts1024to1518Octets Counter,
+ etherStatsOwner OwnerString,
+ etherStatsStatus INTEGER
+ }
+
+ etherStatsIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object uniquely identifies this
+ etherStats entry."
+ ::= { etherStatsEntry 1 }
+
+ etherStatsDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+
+
+ "This object identifies the source of the data that
+ this etherStats entry is configured to analyze. This
+ source can be any ethernet interface on this device.
+ In order to identify a particular interface, this
+ object shall identify the instance of the ifIndex
+ object, defined in [4,6], for the desired interface.
+ For example, if an entry were to receive data from
+ interface #1, this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the
+ identified interface.
+
+ This object may not be modified if the associated
+ etherStatsStatus object is equal to valid(1)."
+ ::= { etherStatsEntry 2 }
+
+ etherStatsDropEvents OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of events in which packets
+ were dropped by the probe due to lack of resources.
+ Note that this number is not necessarily the number of
+ packets dropped; it is just the number of times this
+ condition has been detected."
+ ::= { etherStatsEntry 3 }
+
+ etherStatsOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of octets of data (including
+ those in bad packets) received on the
+ network (excluding framing bits but including
+ FCS octets)."
+ ::= { etherStatsEntry 4 }
+
+ etherStatsPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error packets)
+ received."
+ ::= { etherStatsEntry 5 }
+
+
+ etherStatsBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of good packets received that were
+ directed to the broadcast address."
+ ::= { etherStatsEntry 6 }
+
+ etherStatsMulticastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of good packets received that were
+ directed to a multicast address. Note that this
+ number does not include packets directed to the
+ broadcast address."
+ ::= { etherStatsEntry 7 }
+
+ etherStatsCRCAlignErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets received that
+ had a length (excluding framing bits, but
+ including FCS octets) of between 64 and 1518
+ octets, inclusive, but were not an integral number
+ of octets in length or had a bad Frame Check
+ Sequence (FCS)."
+ ::= { etherStatsEntry 8 }
+
+ etherStatsUndersizePkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets received that were
+ less than 64 octets long (excluding framing bits,
+ but including FCS octets) and were otherwise well
+ formed."
+ ::= { etherStatsEntry 9 }
+
+ etherStatsOversizePkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+
+
+ DESCRIPTION
+ "The total number of packets received that were
+ longer than 1518 octets (excluding framing bits,
+ but including FCS octets) and were otherwise
+ well formed."
+ ::= { etherStatsEntry 10 }
+
+ etherStatsFragments OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets received that were not an
+ integral number of octets in length or that had a bad
+ Frame Check Sequence (FCS), and were less than 64
+ octets in length (excluding framing bits but
+ including FCS octets)."
+ ::= { etherStatsEntry 11 }
+
+ etherStatsJabbers OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets received that were
+ longer than 1518 octets (excluding framing bits,
+ but including FCS octets), and were not an
+ integral number of octets in length or had
+ a bad Frame Check Sequence (FCS)."
+ ::= { etherStatsEntry 12 }
+
+ etherStatsCollisions OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The best estimate of the total number of collisions
+ on this Ethernet segment."
+ ::= { etherStatsEntry 13 }
+
+ etherStatsPkts64Octets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error
+ packets) received that were 64 octets in length
+ (excluding framing bits but including FCS octets)."
+
+
+ ::= { etherStatsEntry 14 }
+
+ etherStatsPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error
+ packets) received that were between
+ 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 15 }
+
+ etherStatsPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error
+ packets) received that were between
+ 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 16 }
+
+ etherStatsPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error
+ packets) received that were between
+ 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 17 }
+
+ etherStatsPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error
+ packets) received that were between
+ 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 18 }
+
+
+
+
+
+ etherStatsPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets (including error
+ packets) received that were between
+ 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 19 }
+
+ etherStatsOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is
+ therefore using the resources assigned to it."
+ ::= { etherStatsEntry 20 }
+
+ etherStatsStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this etherStats entry."
+ ::= { etherStatsEntry 21 }
+
+
+ -- The History Group
+
+ -- Implementation of the History group is optional.
+ --
+ -- The history group records periodic statistical samples from
+ -- a network and stores them for later retrieval. The
+ -- historyControl table stores configuration entries that each
+ -- define an interface, polling period, and other parameters.
+ -- Once samples are taken, their data is stored in an entry
+ -- in a media-specific table. Each such entry defines one
+ -- sample, and is associated with the historyControlEntry that
+ -- caused the sample to be taken. Currently the only media-
+ -- specific table defined is the etherHistoryTable, for
+ -- Ethernet networks.
+ --
+ -- If the probe keeps track of the time of day, it should
+ -- start the first sample of the history at a time such that
+ -- when the next hour of the day begins, a sample is
+ -- started at that instant. This tends to make more
+
+
+ -- user-friendly reports, and enables comparison of reports
+ -- from different probes that have relatively accurate time
+ -- of day.
+ --
+ -- The monitor is encouraged to add two history control entries
+ -- per monitored interface upon initialization that describe
+ -- a short term and a long term polling period. Suggested
+ -- parameters are 30 seconds for the short term polling
+ -- period and 30 minutes for the long term period.
+
+ historyControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HistoryControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of history control entries."
+ ::= { history 1 }
+
+ historyControlEntry OBJECT-TYPE
+ SYNTAX HistoryControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of parameters that set up a periodic
+ sampling of statistics."
+ INDEX { historyControlIndex }
+ ::= { historyControlTable 1 }
+
+ HistoryControlEntry ::= SEQUENCE {
+ historyControlIndex INTEGER (1..65535),
+ historyControlDataSource OBJECT IDENTIFIER,
+ historyControlBucketsRequested INTEGER (1..65535),
+ historyControlBucketsGranted INTEGER (1..65535),
+ historyControlInterval INTEGER (1..3600),
+ historyControlOwner OwnerString,
+ historyControlStatus INTEGER
+ }
+
+ historyControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ historyControl table. Each such entry defines a
+ set of samples at a particular interval for an
+ interface on the device."
+ ::= { historyControlEntry 1 }
+
+
+ historyControlDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object identifies the source of the data for
+ which historical data was collected and
+ placed in a media-specific table on behalf of this
+ historyControlEntry. This source can be any
+ interface on this device. In order to identify
+ a particular interface, this object shall identify
+ the instance of the ifIndex object, defined
+ in [4,6], for the desired interface. For example,
+ if an entry were to receive data from interface #1,
+ this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the
+ identified interface.
+
+ This object may not be modified if the associated
+ historyControlStatus object is equal to valid(1)."
+ ::= { historyControlEntry 2 }
+
+ historyControlBucketsRequested OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The requested number of discrete time intervals
+ over which data is to be saved in the part of the
+ media-specific table associated with this
+ historyControl entry.
+
+ When this object is created or modified, the probe
+ should set historyControlBucketsGranted as closely to
+ this object as is possible for the particular probe
+ implementation and available resources."
+ DEFVAL { 50 }
+ ::= { historyControlEntry 3 }
+
+ historyControlBucketsGranted OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of discrete sampling intervals
+ over which data shall be saved in the part of
+
+
+ the media-specific table associated with this
+ historyControl entry.
+
+ When the associated historyControlBucketsRequested
+ object is created or modified, the probe
+ should set this object as closely to the requested
+ value as is possible for the particular
+ probe implementation and available resources. The
+ probe must not lower this value except as a result
+ of a modification to the associated
+ historyControlBucketsRequested object.
+
+ There will be times when the actual number of
+ buckets associated with this entry is less than
+ the value of this object. In this case, at the
+ end of each sampling interval, a new bucket will
+ be added to the media-specific table.
+
+ When the number of buckets reaches the value of
+ this object and a new bucket is to be added to the
+ media-specific table, the oldest bucket associated
+ with this historyControlEntry shall be deleted by
+ the agent so that the new bucket can be added.
+
+ When the value of this object changes to a value less
+ than the current value, entries are deleted
+ from the media-specific table associated with this
+ historyControlEntry. Enough of the oldest of these
+ entries shall be deleted by the agent so that their
+ number remains less than or equal to the new value of
+ this object.
+
+ When the value of this object changes to a value
+ greater than the current value, the number of
+ associated media-specific entries may be allowed
+ to grow."
+ ::= { historyControlEntry 4 }
+
+ historyControlInterval OBJECT-TYPE
+ SYNTAX INTEGER (1..3600)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The interval in seconds over which the data is
+ sampled for each bucket in the part of the
+ media-specific table associated with this
+ historyControl entry. This interval can
+ be set to any number of seconds between 1 and
+
+
+ 3600 (1 hour).
+
+ Because the counters in a bucket may overflow at their
+ maximum value with no indication, a prudent manager
+ will take into account the possibility of overflow
+ in any of the associated counters. It is important
+ to consider the minimum time in which any counter
+ could overflow on a particular media type and set
+ the historyControlInterval object to a value less
+ than this interval. This is typically most
+ important for the 'octets' counter in any
+ media-specific table. For example, on an Ethernet
+ network, the etherHistoryOctets counter could overflow
+ in about one hour at the Ethernet's maximum
+ utilization.
+
+ This object may not be modified if the associated
+ historyControlStatus object is equal to valid(1)."
+ DEFVAL { 1800 }
+ ::= { historyControlEntry 5 }
+
+ historyControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { historyControlEntry 6 }
+
+ historyControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this historyControl entry.
+
+ Each instance of the media-specific table associated
+ with this historyControlEntry will be deleted by the
+ agent if this historyControlEntry is not equal to
+ valid(1)."
+ ::= { historyControlEntry 7 }
+
+
+ -- Ether History table
+
+ etherHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EtherHistoryEntry
+
+
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of Ethernet history entries."
+ ::= { history 2 }
+
+ etherHistoryEntry OBJECT-TYPE
+ SYNTAX EtherHistoryEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An historical sample of Ethernet statistics on a
+ particular Ethernet interface. This sample is
+ associated with the historyControlEntry which set
+ up the parameters for a regular collection of these
+ samples."
+ INDEX { etherHistoryIndex , etherHistorySampleIndex }
+ ::= { etherHistoryTable 1 }
+
+ EtherHistoryEntry ::= SEQUENCE {
+ etherHistoryIndex INTEGER (1..65535),
+ etherHistorySampleIndex INTEGER,
+ etherHistoryIntervalStart TimeTicks,
+ etherHistoryDropEvents Counter,
+ etherHistoryOctets Counter,
+ etherHistoryPkts Counter,
+ etherHistoryBroadcastPkts Counter,
+ etherHistoryMulticastPkts Counter,
+ etherHistoryCRCAlignErrors Counter,
+ etherHistoryUndersizePkts Counter,
+ etherHistoryOversizePkts Counter,
+ etherHistoryFragments Counter,
+ etherHistoryJabbers Counter,
+ etherHistoryCollisions Counter,
+ etherHistoryUtilization INTEGER (0..10000)
+ }
+
+ etherHistoryIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The history of which this entry is a part. The
+ history identified by a particular value of this
+ index is the same history as identified
+ by the same value of historyControlIndex."
+ ::= { etherHistoryEntry 1 }
+
+
+
+ etherHistorySampleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies the particular
+ sample this entry represents among all samples
+ associated with the same historyControlEntry.
+ This index starts at 1 and increases by one
+ as each new sample is taken."
+ ::= { etherHistoryEntry 2 }
+
+ etherHistoryIntervalStart OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime at the start of the interval
+ over which this sample was measured. If the probe
+ keeps track of the time of day, it should start
+ the first sample of the history at a time such that
+ when the next hour of the day begins, a sample is
+ started at that instant. Note that following this
+ rule may require the probe to delay collecting the
+ first sample of the history, as each sample must be
+ of the same interval. Also note that the sample which
+ is currently being collected is not accessible in this
+ table until the end of its interval."
+ ::= { etherHistoryEntry 3 }
+
+ etherHistoryDropEvents OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of events in which packets
+ were dropped by the probe due to lack of resources
+ during this interval. Note that this number is not
+ necessarily the number of packets dropped, it is just
+ the number of times this condition has been detected."
+ ::= { etherHistoryEntry 4 }
+
+ etherHistoryOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of octets of data (including
+
+
+ those in bad packets) received on the
+ network (excluding framing bits but including
+ FCS octets)."
+ ::= { etherHistoryEntry 5 }
+
+ etherHistoryPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets (including error packets)
+ received during this sampling interval."
+ ::= { etherHistoryEntry 6 }
+
+ etherHistoryBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of good packets received during this
+ sampling interval that were directed to the
+ broadcast address."
+ ::= { etherHistoryEntry 7 }
+
+ etherHistoryMulticastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of good packets received during this
+ sampling interval that were directed to a
+ multicast address. Note that this number does not
+ include packets addressed to the broadcast address."
+ ::= { etherHistoryEntry 8 }
+
+ etherHistoryCRCAlignErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets received during this
+ sampling interval that had a length (excluding
+ framing bits but including FCS octets) between
+ 64 and 1518 octets, inclusive, but were not an
+ integral number of octets in length or had a
+ bad Frame Check Sequence (FCS)."
+ ::= { etherHistoryEntry 9 }
+
+
+
+ etherHistoryUndersizePkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets received during this
+ interval that were less than 64 octets long
+ (excluding framing bits but including FCS
+ octets) and were otherwise well formed."
+ ::= { etherHistoryEntry 10 }
+
+ etherHistoryOversizePkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets received during this
+ interval that were longer than 1518 octets
+ (excluding framing bits but including FCS
+ octets) but were otherwise well formed."
+ ::= { etherHistoryEntry 11 }
+
+ etherHistoryFragments OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of packets received during this
+ sampling interval that were not an integral
+ number of octets in length or that
+ had a bad Frame Check Sequence (FCS), and
+ were less than 64 octets in length (excluding
+ framing bits but including FCS octets)."
+ ::= { etherHistoryEntry 12 }
+
+ etherHistoryJabbers OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets received during this
+ interval that were longer than 1518 octets
+ (excluding framing bits but including FCS octets),
+ and were not an integral number of octets in
+ length or had a bad Frame Check Sequence (FCS)."
+ ::= { etherHistoryEntry 13 }
+
+
+
+
+ etherHistoryCollisions OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The best estimate of the total number of collisions
+ on this Ethernet segment during this interval."
+ ::= { etherHistoryEntry 14 }
+
+ etherHistoryUtilization OBJECT-TYPE
+ SYNTAX INTEGER (0..10000)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The best estimate of the mean physical layer
+ network utilization on this interface during this
+ interval, in hundredths of a percent."
+ ::= { etherHistoryEntry 15 }
+
+
+ -- The Alarm Group
+
+ -- Implementation of the Alarm group is optional.
+ --
+ -- The Alarm Group requires the implementation of the Event
+ -- group.
+ --
+ -- The Alarm group periodically takes statistical samples from
+ -- variables in the probe and compares them to thresholds
+ -- that have been configured. The alarm table stores
+ -- configuration entries that each define a variable,
+ -- polling period, and threshold parameters. If a sample is
+ -- found to cross the threshold values, an event is
+ -- generated. Only variables that resolve to an ASN.1
+ -- primitive type of INTEGER (INTEGER, Counter,
+ -- Gauge, or TimeTicks) may be monitored in this way.
+ --
+ -- This function has a hysteresis mechanism to limit the
+ -- generation of events. This mechanism generates one event
+ -- as a threshold is crossed in the appropriate direction.
+ -- No more events are generated for that threshold until the
+ -- opposite threshold is crossed.
+ --
+ -- In the case of a sampling a deltaValue, a probe may
+ -- implement this mechanism with more precision if it takes
+ -- a delta sample twice per period, each time comparing the
+ -- sum of the latest two samples to the threshold. This
+ -- allows the detection of threshold crossings
+
+
+ -- that span the sampling boundary. Note that this does not
+ -- require any special configuration of the threshold value.
+ -- It is suggested that probes implement this more precise
+ -- algorithm.
+
+ alarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of alarm entries."
+ ::= { alarm 1 }
+
+ alarmEntry OBJECT-TYPE
+ SYNTAX AlarmEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of parameters that set up a periodic checking
+ for alarm conditions."
+ INDEX { alarmIndex }
+ ::= { alarmTable 1 }
+
+ AlarmEntry ::= SEQUENCE {
+ alarmIndex INTEGER (1..65535),
+ alarmInterval INTEGER,
+ alarmVariable OBJECT IDENTIFIER,
+ alarmSampleType INTEGER,
+ alarmValue INTEGER,
+ alarmStartupAlarm INTEGER,
+ alarmRisingThreshold INTEGER,
+ alarmFallingThreshold INTEGER,
+ alarmRisingEventIndex INTEGER (1..65535),
+ alarmFallingEventIndex INTEGER (1..65535),
+ alarmOwner OwnerString,
+ alarmStatus INTEGER
+ }
+
+ alarmIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ alarm table. Each such entry defines a
+ diagnostic sample at a particular interval
+ for an object on the device."
+ ::= { alarmEntry 1 }
+
+
+ alarmInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The interval in seconds over which the data is
+ sampled and compared with the rising and falling
+ thresholds. When setting this variable, care
+ should be given to ensure that the variable being
+ monitored will not exceed 2^31 - 1 and roll
+ over the alarmValue object during the interval.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 2 }
+
+ alarmVariable OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The object identifier of the particular variable to
+ be sampled. Only variables that resolve to an ASN.1
+ primitive type of INTEGER (INTEGER, Counter, Gauge,
+ or TimeTicks) may be sampled.
+
+ Because SNMP access control is articulated entirely
+ in terms of the contents of MIB views, no access
+ control mechanism exists that can restrict the value of
+ this object to identify only those objects that exist
+ in a particular MIB view. Because there is thus no
+ acceptable means of restricting the read access that
+ could be obtained through the alarm mechanism, the
+ probe must only grant write access to this object in
+ those views that have read access to all objects on
+ the probe.
+
+ During a set operation, if the supplied variable
+ name is not available in the selected MIB view, a
+ badValue error must be returned. If at any time
+ the variable name of an established alarmEntry is
+ no longer available in the selected MIB view, the
+ probe must change the status of this alarmEntry
+ to invalid(4).
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 3 }
+
+
+ alarmSampleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ absoluteValue(1),
+ deltaValue(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The method of sampling the selected variable and
+ calculating the value to be compared against the
+ thresholds. If the value of this object is
+ absoluteValue(1), the value of the selected variable
+ will be compared directly with the thresholds at the
+ end of the sampling interval. If the value of this
+ object is deltaValue(2), the value of the selected
+ variable at the last sample will be subtracted from
+ the current value, and the difference compared with
+ the thresholds.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 4 }
+
+ alarmValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of the statistic during the last sampling
+ period. The value during the current sampling period
+ is not made available until the period is completed."
+ ::= { alarmEntry 5 }
+
+ alarmStartupAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ risingAlarm(1),
+ fallingAlarm(2),
+ risingOrFallingAlarm(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm that may be sent when this entry is first
+ set to valid. If the first sample after this entry
+ becomes valid is greater than or equal to the
+ risingThreshold and alarmStartupAlarm is equal to
+ risingAlarm(1) or risingOrFallingAlarm(3), then a
+ single rising alarm will be generated. If the first
+
+
+ sample after this entry becomes valid is less than
+ or equal to the fallingThreshold and
+ alarmStartupAlarm is equal to fallingAlarm(2) or
+ risingOrFallingAlarm(3), then a single falling
+ alarm will be generated.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 6 }
+
+ alarmRisingThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold for the sampled statistic. When the
+ current sampled value is greater than or equal to
+ this threshold, and the value at the last sampling
+ interval was less than this threshold, a single
+ event will be generated.
+ A single event will also be generated if the first
+ sample after this entry becomes valid is greater
+ than or equal to this threshold and the associated
+ alarmStartupAlarm is equal to risingAlarm(1) or
+ risingOrFallingAlarm(3).
+
+ After a rising event is generated, another such event
+ will not be generated until the sampled value
+ falls below this threshold and reaches the
+ alarmFallingThreshold.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 7 }
+
+ alarmFallingThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold for the sampled statistic. When the
+ current sampled value is less than or equal to
+ this threshold, and the value at the last sampling
+ interval was greater than this threshold, a single
+ event will be generated.
+ A single event will also be generated if the first
+ sample after this entry becomes valid is less than or
+ equal to this threshold and the associated
+
+
+ alarmStartupAlarm is equal to fallingAlarm(2) or
+ risingOrFallingAlarm(3).
+
+ After a falling event is generated, another such event
+ will not be generated until the sampled value
+ rises above this threshold and reaches the
+ alarmRisingThreshold.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 8 }
+
+ alarmRisingEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the eventEntry that is
+ used when a rising threshold is crossed. The
+ eventEntry identified by a particular value of
+ this index is the same as identified by the same value
+ of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then
+ no association exists. In particular, if this value
+ is zero, no associated event will be generated, as
+ zero is not a valid event index.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 9 }
+
+ alarmFallingEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the eventEntry that is
+ used when a falling threshold is crossed. The
+ eventEntry identified by a particular value of
+ this index is the same as identified by the same value
+ of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then
+ no association exists. In particular, if this value
+ is zero, no associated event will be generated, as
+ zero is not a valid event index.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+
+
+ ::= { alarmEntry 10 }
+
+ alarmOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is
+ therefore using the resources assigned to it."
+ ::= { alarmEntry 11 }
+
+ alarmStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this alarm entry."
+ ::= { alarmEntry 12 }
+
+
+ -- The Host Group
+
+ -- Implementation of the Host group is optional.
+ --
+ -- The host group discovers new hosts on the network by
+ -- keeping a list of source and destination MAC Addresses seen
+ -- in good packets. For each of these addresses, the host
+ -- group keeps a set of statistics. The hostControlTable
+ -- controls which interfaces this function is performed on,
+ -- and contains some information about the process. On
+ -- behalf of each hostControlEntry, data is collected on an
+ -- interface and placed both the hostTable and the
+ -- hostTimeTable. If the monitoring device finds itself
+ -- short of resources, it may delete entries as needed. It
+ -- is suggested that the device delete the least recently
+ -- used entries first.
+
+ -- The hostTable contains entries for each address
+ -- discovered on a particular interface. Each entry
+ -- contains statistical data about that host. This table
+ -- is indexed by the MAC address of the host, through
+ -- which a random access may be achieved.
+
+ -- The hostTimeTable contains data in the same format as the
+ -- hostTable, and must contain the same set of hosts, but is
+ -- indexed using hostTimeCreationOrder rather than hostAddress.
+ -- The hostTimeCreationOrder is an integer which reflects
+ -- the relative order in which a particular entry was
+
+
+ -- discovered and thus inserted into the table. As this
+ -- order, and thus index, is among those entries currently
+ -- in the table, the index for a particular entry may change
+ -- if an (earlier) entry is deleted. Thus the association
+ -- between hostTimeCreationOrder and hostTimeEntry may be
+ -- broken at any time.
+
+ -- The hostTimeTable has two important uses. The first is the
+ -- fast download of this potentially large table. Because the
+ -- index of this table runs from 1 to the size of the table,
+ -- inclusive, its values are predictable. This allows very
+ -- efficient packing of variables into SNMP PDU's and allows
+ -- a table transfer to have multiple packets outstanding.
+ -- These benefits increase transfer rates tremendously.
+
+ -- The second use of the hostTimeTable is the efficient
+ -- discovery by the management station of new entries added
+ -- to the table. After the management station has
+ -- downloaded the entire table, it knows that new entries
+ -- will be added immediately after the end of the current
+ -- table. It can thus detect new entries there
+ -- and retrieve them easily.
+
+ -- Because the association between hostTimeCreationOrder and
+ -- hostTimeEntry may be broken at any time, the management
+ -- station must monitor the related hostControlLastDeleteTime
+ -- object. When the management station thus detects a deletion,
+ -- it must assume that any such associations have been broken,
+ -- and invalidate any it has stored locally. This includes
+ -- restarting any download of the hostTimeTable that may have
+ -- been in progress, as well as rediscovering the end of the
+ -- hostTimeTable so that it may detect new entries. If the
+ -- management station does not detect the broken association,
+ -- it may continue to refer to a particular host by its
+ -- creationOrder while unwittingly retrieving the data
+ -- associated with another host entirely. If this happens
+ -- while downloading the host table, the management station
+ -- may fail to download all of the entries in the table.
+
+
+ hostControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of host table control entries."
+ ::= { hosts 1 }
+
+
+
+ hostControlEntry OBJECT-TYPE
+ SYNTAX HostControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of parameters that set up the discovery of
+ hosts on a particular interface and the collection
+ of statistics about these hosts."
+ INDEX { hostControlIndex }
+ ::= { hostControlTable 1 }
+
+ HostControlEntry ::= SEQUENCE {
+ hostControlIndex INTEGER (1..65535),
+ hostControlDataSource OBJECT IDENTIFIER,
+ hostControlTableSize INTEGER,
+ hostControlLastDeleteTime TimeTicks,
+ hostControlOwner OwnerString,
+ hostControlStatus INTEGER
+ }
+
+ hostControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ hostControl table. Each such entry defines
+ a function that discovers hosts on a particular
+ interface and places statistics about them in the
+ hostTable and the hostTimeTable on behalf of this
+ hostControlEntry."
+ ::= { hostControlEntry 1 }
+
+ hostControlDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object identifies the source of the data for
+ this instance of the host function. This source
+ can be any interface on this device. In order
+ to identify a particular interface, this object shall
+ identify the instance of the ifIndex object, defined
+ in [4,6], for the desired interface. For example,
+ if an entry were to receive data from interface #1,
+ this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+
+
+ on the local network segment attached to the
+ identified interface.
+
+ This object may not be modified if the associated
+ hostControlStatus object is equal to valid(1)."
+ ::= { hostControlEntry 2 }
+
+ hostControlTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of hostEntries in the hostTable and the
+ hostTimeTable associated with this hostControlEntry."
+ ::= { hostControlEntry 3 }
+
+ hostControlLastDeleteTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime when the last entry
+ was deleted from the portion of the hostTable
+ associated with this hostControlEntry. If no
+ deletions have occurred, this value shall be zero."
+ ::= { hostControlEntry 4 }
+
+ hostControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is
+ therefore using the resources assigned to it."
+ ::= { hostControlEntry 5 }
+
+ hostControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this hostControl entry.
+
+ If this object is not equal to valid(1), all
+ associated entries in the hostTable,
+ hostTimeTable, and the hostTopNTable shall be
+ deleted by the agent."
+ ::= { hostControlEntry 6 }
+
+
+ hostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of host entries."
+ ::= { hosts 2 }
+
+ hostEntry OBJECT-TYPE
+ SYNTAX HostEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A collection of statistics for a particular host
+ that has been discovered on an interface of this
+ device."
+ INDEX { hostIndex, hostAddress }
+ ::= { hostTable 1 }
+
+ HostEntry ::= SEQUENCE {
+ hostAddress OCTET STRING,
+ hostCreationOrder INTEGER (1..65535),
+ hostIndex INTEGER (1..65535),
+ hostInPkts Counter,
+ hostOutPkts Counter,
+ hostInOctets Counter,
+ hostOutOctets Counter,
+ hostOutErrors Counter,
+ hostOutBroadcastPkts Counter,
+ hostOutMulticastPkts Counter
+ }
+
+ hostAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical address of this host."
+ ::= { hostEntry 1 }
+
+ hostCreationOrder OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that defines the relative ordering of
+ the creation time of hosts captured for a
+ particular hostControlEntry. This index shall
+
+
+ be between 1 and N, where N is the value of
+ the associated hostControlTableSize. The ordering
+ of the indexes is based on the order of each entry's
+ insertion into the table, in which entries added
+ earlier have a lower index value than entries added
+ later.
+
+ It is important to note that the order for a
+ particular entry may change as an (earlier) entry
+ is deleted from the table. Because this order may
+ change, management stations should make use of the
+ hostControlLastDeleteTime variable in the
+ hostControlEntry associated with the relevant
+ portion of the hostTable. By observing
+ this variable, the management station may detect
+ the circumstances where a previous association
+ between a value of hostCreationOrder
+ and a hostEntry may no longer hold."
+ ::= { hostEntry 2 }
+
+ hostIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The set of collected host statistics of which
+ this entry is a part. The set of hosts
+ identified by a particular value of this
+ index is associated with the hostControlEntry
+ as identified by the same value of hostControlIndex."
+ ::= { hostEntry 3 }
+
+ hostInPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets without errors transmitted to
+ this address since it was added to the hostTable."
+ ::= { hostEntry 4 }
+
+ hostOutPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets including errors transmitted
+ by this address since it was added to the hostTable."
+
+
+ ::= { hostEntry 5 }
+
+ hostInOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets transmitted to this address
+ since it was added to the hostTable (excluding
+ framing bits but including FCS octets), except for
+ those octets in packets that contained errors."
+ ::= { hostEntry 6 }
+
+ hostOutOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets transmitted by this address
+ since it was added to the hostTable (excluding
+ framing bits but including FCS octets), including
+ those octets in packets that contained errors."
+ ::= { hostEntry 7 }
+
+ hostOutErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of error packets transmitted by this
+ address since this host was added to the hostTable."
+ ::= { hostEntry 8 }
+
+ hostOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to the broadcast address
+ since this host was added to the hostTable."
+ ::= { hostEntry 9 }
+
+ hostOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+
+
+ "The number of good packets transmitted by this
+ address that were directed to a multicast address
+ since this host was added to the hostTable.
+ Note that this number does not include packets
+ directed to the broadcast address."
+ ::= { hostEntry 10 }
+
+
+ -- host Time Table
+
+ hostTimeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostTimeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of time-ordered host table entries."
+ ::= { hosts 3 }
+
+ hostTimeEntry OBJECT-TYPE
+ SYNTAX HostTimeEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A collection of statistics for a particular host
+ that has been discovered on an interface of this
+ device. This collection includes the relative
+ ordering of the creation time of this object."
+ INDEX { hostTimeIndex, hostTimeCreationOrder }
+ ::= { hostTimeTable 1 }
+
+ HostTimeEntry ::= SEQUENCE {
+ hostTimeAddress OCTET STRING,
+ hostTimeCreationOrder INTEGER (1..65535),
+ hostTimeIndex INTEGER (1..65535),
+ hostTimeInPkts Counter,
+ hostTimeOutPkts Counter,
+ hostTimeInOctets Counter,
+ hostTimeOutOctets Counter,
+ hostTimeOutErrors Counter,
+ hostTimeOutBroadcastPkts Counter,
+ hostTimeOutMulticastPkts Counter
+ }
+
+ hostTimeAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+
+
+ "The physical address of this host."
+ ::= { hostTimeEntry 1 }
+
+ hostTimeCreationOrder OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in
+ the hostTime table among those entries associated
+ with the same hostControlEntry. This index shall
+ be between 1 and N, where N is the value of
+ the associated hostControlTableSize. The ordering
+ of the indexes is based on the order of each entry's
+ insertion into the table, in which entries added
+ earlier have a lower index value than entries added
+ later. Thus the management station has the ability
+ to learn of new entries added to this table without
+ downloading the entire table.
+
+ It is important to note that the index for a
+ particular entry may change as an (earlier) entry
+ is deleted from the table. Because this order may
+ change, management stations should make use of the
+ hostControlLastDeleteTime variable in the
+ hostControlEntry associated with the relevant
+ portion of the hostTimeTable. By observing
+ this variable, the management station may detect
+ the circumstances where a download of the table
+ may have missed entries, and where a previous
+ association between a value of hostTimeCreationOrder
+ and a hostTimeEntry may no longer hold."
+ ::= { hostTimeEntry 2 }
+
+ hostTimeIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The set of collected host statistics of which
+ this entry is a part. The set of hosts
+ identified by a particular value of this
+ index is associated with the hostControlEntry
+ as identified by the same value of hostControlIndex."
+ ::= { hostTimeEntry 3 }
+
+
+
+
+
+ hostTimeInPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets without errors transmitted to
+ this address since it was added to the hostTimeTable."
+ ::= { hostTimeEntry 4 }
+
+ hostTimeOutPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets including errors transmitted
+ by this address since it was added to the
+ hostTimeTable."
+ ::= { hostTimeEntry 5 }
+
+ hostTimeInOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets transmitted to this address
+ since it was added to the hostTimeTable (excluding
+ framing bits but including FCS octets), except for
+ those octets in packets that contained errors."
+ ::= { hostTimeEntry 6 }
+
+ hostTimeOutOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets transmitted by this address since
+ it was added to the hostTimeTable (excluding framing
+ bits but including FCS octets), including those
+ octets in packets that contained errors."
+ ::= { hostTimeEntry 7 }
+
+ hostTimeOutErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of error packets transmitted by this
+ address since this host was added to the
+
+
+ hostTimeTable."
+ ::= { hostTimeEntry 8 }
+
+ hostTimeOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to the broadcast address
+ since this host was added to the hostTimeTable."
+ ::= { hostTimeEntry 9 }
+
+ hostTimeOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to a multicast address
+ since this host was added to the hostTimeTable.
+ Note that this number does not include packets
+ directed to the broadcast address."
+ ::= { hostTimeEntry 10 }
+
+
+ -- The Host Top "N" Group
+
+ -- Implementation of the Host Top N group is optional.
+ --
+ -- The Host Top N group requires the implementation of the
+ -- host group.
+ --
+ -- The Host Top N group is used to prepare reports that
+ -- describe the hosts that top a list ordered by one of
+ -- their statistics. The available statistics are samples
+ -- of one of their base statistics, over an interval
+ -- specified by the management station. Thus, these
+ -- statistics are rate based. The management
+ -- station also selects how many such hosts are reported.
+
+ -- The hostTopNControlTable is used to initiate the generation
+ -- of such a report. The management station may select the
+ -- parameters of such a report, such as which interface,
+ -- which statistic, how many hosts, and the start and stop
+ -- times of the sampling. When the report is prepared,
+ -- entries are created in the hostTopNTable associated with
+ -- the relevant hostTopNControlEntry. These entries are
+
+
+ -- static for each report after it has been prepared.
+
+ hostTopNControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostTopNControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of top N host control entries."
+ ::= { hostTopN 1 }
+
+ hostTopNControlEntry OBJECT-TYPE
+ SYNTAX HostTopNControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of parameters that control the creation of a
+ report of the top N hosts according to several
+ metrics."
+ INDEX { hostTopNControlIndex }
+ ::= { hostTopNControlTable 1 }
+
+ HostTopNControlEntry ::= SEQUENCE {
+ hostTopNControlIndex INTEGER (1..65535),
+ hostTopNHostIndex INTEGER (1..65535),
+ hostTopNRateBase INTEGER,
+ hostTopNTimeRemaining INTEGER,
+ hostTopNDuration INTEGER,
+ hostTopNRequestedSize INTEGER,
+ hostTopNGrantedSize INTEGER,
+ hostTopNStartTime TimeTicks,
+ hostTopNOwner OwnerString,
+ hostTopNStatus INTEGER
+ }
+
+ hostTopNControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the hostTopNControl table. Each such
+ entry defines one top N report prepared for
+ one interface."
+ ::= { hostTopNControlEntry 1 }
+
+ hostTopNHostIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "The host table for which a top N report will be
+ prepared on behalf of this entry. The host table
+ identified by a particular value of this index is
+ associated with the same host table as identified
+ by the same value of hostIndex.
+
+ This object may not be modified if the associated
+ hostTopNStatus object is equal to valid(1)."
+ ::= { hostTopNControlEntry 2 }
+
+ hostTopNRateBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ hostTopNInPkts(1),
+ hostTopNOutPkts(2),
+ hostTopNInOctets(3),
+ hostTopNOutOctets(4),
+ hostTopNOutErrors(5),
+ hostTopNOutBroadcastPkts(6),
+ hostTopNOutMulticastPkts(7)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The variable for each host that the hostTopNRate
+ variable is based upon.
+
+ This object may not be modified if the associated
+ hostTopNStatus object is equal to valid(1)."
+ ::= { hostTopNControlEntry 3 }
+
+ hostTopNTimeRemaining OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of seconds left in the report currently
+ being collected. When this object is modified by
+ the management station, a new collection is started,
+ possibly aborting a currently running report. The
+ new value is used as the requested duration of this
+ report, which is loaded into the associated
+ hostTopNDuration object.
+
+ When this object is set to a non-zero value, any
+ associated hostTopNEntries shall be made
+ inaccessible by the monitor. While the value of this
+
+
+ object is non-zero, it decrements by one per second
+ until it reaches zero. During this time, all
+ associated hostTopNEntries shall remain
+ inaccessible. At the time that this object
+ decrements to zero, the report is made
+ accessible in the hostTopNTable. Thus, the hostTopN
+ table needs to be created only at the end of the
+ collection interval."
+ DEFVAL { 0 }
+ ::= { hostTopNControlEntry 4 }
+
+ hostTopNDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of seconds that this report has collected
+ during the last sampling interval, or if this
+ report is currently being collected, the number
+ of seconds that this report is being collected
+ during this sampling interval.
+
+ When the associated hostTopNTimeRemaining object is
+ set, this object shall be set by the probe to the
+ same value and shall not be modified until the next
+ time the hostTopNTimeRemaining is set.
+
+ This value shall be zero if no reports have been
+ requested for this hostTopNControlEntry."
+ DEFVAL { 0 }
+ ::= { hostTopNControlEntry 5 }
+
+ hostTopNRequestedSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of hosts requested for the top N
+ table.
+
+ When this object is created or modified, the probe
+ should set hostTopNGrantedSize as closely to this
+ object as is possible for the particular probe
+ implementation and available resources."
+ DEFVAL { 10 }
+ ::= { hostTopNControlEntry 6 }
+
+
+
+
+ hostTopNGrantedSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of hosts in the top N table.
+
+ When the associated hostTopNRequestedSize object is
+ created or modified, the probe should set this
+ object as closely to the requested value as is
+ possible for the particular implementation and
+ available resources. The probe must not lower this
+ value except as a result of a set to the associated
+ hostTopNRequestedSize object.
+
+ Hosts with the highest value of hostTopNRate shall be
+ placed in this table in decreasing order of this rate
+ until there is no more room or until there are no more
+ hosts."
+ ::= { hostTopNControlEntry 7 }
+
+ hostTopNStartTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime when this top N report was
+ last started. In other words, this is the time that
+ the associated hostTopNTimeRemaining object was
+ modified to start the requested report."
+ ::= { hostTopNControlEntry 8 }
+
+ hostTopNOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is
+ therefore using the resources assigned to it."
+ ::= { hostTopNControlEntry 9 }
+
+ hostTopNStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this hostTopNControl entry.
+
+
+
+ If this object is not equal to valid(1), all
+ associated hostTopNEntries shall be deleted by
+ the agent."
+ ::= { hostTopNControlEntry 10 }
+
+ hostTopNTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostTopNEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of top N host entries."
+ ::= { hostTopN 2 }
+
+ hostTopNEntry OBJECT-TYPE
+ SYNTAX HostTopNEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of statistics for a host that is part of a
+ top N report."
+ INDEX { hostTopNReport, hostTopNIndex }
+ ::= { hostTopNTable 1 }
+
+ HostTopNEntry ::= SEQUENCE {
+ hostTopNReport INTEGER (1..65535),
+ hostTopNIndex INTEGER (1..65535),
+ hostTopNAddress OCTET STRING,
+ hostTopNRate INTEGER
+ }
+
+ hostTopNReport OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object identifies the top N report of which
+ this entry is a part. The set of hosts
+ identified by a particular value of this
+ object is part of the same report as identified
+ by the same value of the hostTopNControlIndex object."
+ ::= { hostTopNEntry 1 }
+
+ hostTopNIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in
+
+
+ the hostTopN table among those in the same report.
+ This index is between 1 and N, where N is the
+ number of entries in this table. Increasing values
+ of hostTopNIndex shall be assigned to entries with
+ decreasing values of hostTopNRate until index N
+ is assigned to the entry with the lowest value of
+ hostTopNRate or there are no more hostTopNEntries."
+ ::= { hostTopNEntry 2 }
+
+ hostTopNAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The physical address of this host."
+ ::= { hostTopNEntry 3 }
+
+ hostTopNRate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of change in the selected variable
+ during this sampling interval. The selected
+ variable is this host's instance of the object
+ selected by hostTopNRateBase."
+ ::= { hostTopNEntry 4 }
+
+
+ -- The Matrix Group
+
+ -- Implementation of the Matrix group is optional.
+ --
+ -- The Matrix group consists of the matrixControlTable,
+ -- matrixSDTable and the matrixDSTable. These tables
+ -- store statistics for a particular conversation between
+ -- two addresses. As the device detects a new conversation,
+ -- including those to a non-unicast address, it creates a
+ -- new entry in both of the matrix tables.
+ -- It must only create new entries based on information
+ -- received in good packets. If the monitoring device finds
+ -- itself short of resources, it may delete entries as needed.
+ -- It is suggested that the device delete the least recently
+ -- used entries first.
+
+ matrixControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MatrixControlEntry
+ ACCESS not-accessible
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "A list of information entries for the
+ traffic matrix on each interface."
+ ::= { matrix 1 }
+
+ matrixControlEntry OBJECT-TYPE
+ SYNTAX MatrixControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Information about a traffic matrix on a
+ particular interface."
+ INDEX { matrixControlIndex }
+ ::= { matrixControlTable 1 }
+
+ MatrixControlEntry ::= SEQUENCE {
+ matrixControlIndex INTEGER (1..65535),
+ matrixControlDataSource OBJECT IDENTIFIER,
+ matrixControlTableSize INTEGER,
+ matrixControlLastDeleteTime TimeTicks,
+ matrixControlOwner OwnerString,
+ matrixControlStatus INTEGER
+ }
+
+ matrixControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ matrixControl table. Each such entry defines
+ a function that discovers conversations on a particular
+ interface and places statistics about them in the
+ matrixSDTable and the matrixDSTable on behalf of this
+ matrixControlEntry."
+ ::= { matrixControlEntry 1 }
+
+ matrixControlDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object identifies the source of
+ the data from which this entry creates a traffic matrix.
+ This source can be any interface on this device. In
+ order to identify a particular interface, this object
+ shall identify the instance of the ifIndex object,
+
+
+ defined in [4,6], for the desired interface. For
+ example, if an entry were to receive data from
+ interface #1, this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the
+ identified interface.
+
+ This object may not be modified if the associated
+ matrixControlStatus object is equal to valid(1)."
+ ::= { matrixControlEntry 2 }
+
+ matrixControlTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of matrixSDEntries in the matrixSDTable
+ for this interface. This must also be the value of
+ the number of entries in the matrixDSTable for this
+ interface."
+ ::= { matrixControlEntry 3 }
+
+ matrixControlLastDeleteTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime when the last entry
+ was deleted from the portion of the matrixSDTable
+ or matrixDSTable associated with this
+ matrixControlEntry.
+ If no deletions have occurred, this value shall be
+ zero."
+ ::= { matrixControlEntry 4 }
+
+ matrixControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is
+ therefore using the resources assigned to it."
+ ::= { matrixControlEntry 5 }
+
+ matrixControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this matrixControl entry.
+
+ If this object is not equal to valid(1), all
+ associated entries in the matrixSDTable and the
+ matrixDSTable shall be deleted by the agent."
+ ::= { matrixControlEntry 6 }
+
+ matrixSDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MatrixSDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of traffic matrix entries indexed by
+ source and destination MAC address."
+ ::= { matrix 2 }
+
+ matrixSDEntry OBJECT-TYPE
+ SYNTAX MatrixSDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A collection of statistics for communications between
+ two addresses on a particular interface."
+ INDEX { matrixSDIndex,
+ matrixSDSourceAddress, matrixSDDestAddress }
+ ::= { matrixSDTable 1 }
+
+ MatrixSDEntry ::= SEQUENCE {
+ matrixSDSourceAddress OCTET STRING,
+ matrixSDDestAddress OCTET STRING,
+ matrixSDIndex INTEGER (1..65535),
+ matrixSDPkts Counter,
+ matrixSDOctets Counter,
+ matrixSDErrors Counter
+ }
+
+ matrixSDSourceAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The source physical address."
+ ::= { matrixSDEntry 1 }
+
+
+
+
+
+ matrixSDDestAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The destination physical address."
+ ::= { matrixSDEntry 2 }
+
+ matrixSDIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The set of collected matrix statistics of which
+ this entry is a part. The set of matrix statistics
+ identified by a particular value of this index
+ is associated with the same matrixControlEntry
+ as identified by the same value of matrixControlIndex."
+ ::= { matrixSDEntry 3 }
+
+ matrixSDPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets transmitted from the source
+ address to the destination address (this number
+ includes error packets)."
+ ::= { matrixSDEntry 4 }
+
+ matrixSDOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets (excluding framing bits but
+ including FCS octets) contained in all packets
+ transmitted from the source address to the
+ destination address."
+ ::= { matrixSDEntry 5 }
+
+ matrixSDErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of error packets transmitted from
+ the source address to the destination address."
+
+
+ ::= { matrixSDEntry 6 }
+
+
+ -- Traffic matrix tables from destination to source
+
+ matrixDSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MatrixDSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of traffic matrix entries indexed by
+ destination and source MAC address."
+ ::= { matrix 3 }
+
+ matrixDSEntry OBJECT-TYPE
+ SYNTAX MatrixDSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A collection of statistics for communications between
+ two address on a particular interface."
+ INDEX { matrixDSIndex,
+ matrixDSDestAddress, matrixDSSourceAddress }
+ ::= { matrixDSTable 1 }
+
+ MatrixDSEntry ::= SEQUENCE {
+ matrixDSSourceAddress OCTET STRING,
+ matrixDSDestAddress OCTET STRING,
+ matrixDSIndex INTEGER (1..65535),
+ matrixDSPkts Counter,
+ matrixDSOctets Counter,
+ matrixDSErrors Counter
+ }
+
+ matrixDSSourceAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The source physical address."
+ ::= { matrixDSEntry 1 }
+
+ matrixDSDestAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The destination physical address."
+
+
+ ::= { matrixDSEntry 2 }
+
+ matrixDSIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The set of collected matrix statistics of which
+ this entry is a part. The set of matrix statistics
+ identified by a particular value of this index
+ is associated with the same matrixControlEntry
+ as identified by the same value of matrixControlIndex."
+ ::= { matrixDSEntry 3 }
+
+ matrixDSPkts OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets transmitted from the source
+ address to the destination address (this number
+ includes error packets)."
+ ::= { matrixDSEntry 4 }
+
+ matrixDSOctets OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of octets (excluding framing bits
+ but including FCS octets) contained in all packets
+ transmitted from the source address to the
+ destination address."
+ ::= { matrixDSEntry 5 }
+
+ matrixDSErrors OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of error packets transmitted from
+ the source address to the destination address."
+ ::= { matrixDSEntry 6 }
+
+
+ -- The Filter Group
+
+ -- Implementation of the Filter group is optional.
+
+
+ --
+ -- The Filter group allows packets to be captured with an
+ -- arbitrary filter expression. A logical data and
+ -- event stream or "channel" is formed by the packets
+ -- that match the filter expression.
+ --
+ -- This filter mechanism allows the creation of an arbitrary
+ -- logical expression with which to filter packets. Each
+ -- filter associated with a channel is OR'ed with the others.
+ -- Within a filter, any bits checked in the data and status are
+ -- AND'ed with respect to other bits in the same filter. The
+ -- NotMask also allows for checking for inequality. Finally,
+ -- the channelAcceptType object allows for inversion of the
+ -- whole equation.
+ --
+ -- The channel can be turned on or off, and can also
+ -- generate events when packets pass through it.
+
+ filterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FilterEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of packet filter entries."
+ ::= { filter 1 }
+
+ filterEntry OBJECT-TYPE
+ SYNTAX FilterEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of parameters for a packet filter applied on a
+ particular interface."
+ INDEX { filterIndex }
+ ::= { filterTable 1 }
+
+ FilterEntry ::= SEQUENCE {
+ filterIndex INTEGER (1..65535),
+ filterChannelIndex INTEGER (1..65535),
+ filterPktDataOffset INTEGER,
+ filterPktData OCTET STRING,
+ filterPktDataMask OCTET STRING,
+ filterPktDataNotMask OCTET STRING,
+ filterPktStatus INTEGER,
+ filterPktStatusMask INTEGER,
+ filterPktStatusNotMask INTEGER,
+ filterOwner OwnerString,
+ filterStatus INTEGER
+
+
+ }
+
+ filterIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the filter table. Each such entry defines
+ one filter that is to be applied to every packet
+ received on an interface."
+ ::= { filterEntry 1 }
+
+ filterChannelIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object identifies the channel of which this
+ filter is a part. The filters identified by a
+ particular value of this object are associated
+ with the same channel as identified by the same
+ value of the channelIndex object."
+ ::= { filterEntry 2 }
+
+ filterPktDataOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The offset from the beginning of each packet where
+ a match of packet data will be attempted. This offset
+ is measured from the point in the physical layer
+ packet after the framing bits, if any. For example,
+ in an Ethernet frame, this point is at the beginning
+ of the destination MAC address.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ DEFVAL { 0 }
+ ::= { filterEntry 3 }
+
+ filterPktData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The data that is to be matched with the input packet.
+
+
+ For each packet received, this filter and the
+ accompanying filterPktDataMask and
+ filterPktDataNotMask will be adjusted for the
+ offset. The only bits relevant to this
+ match algorithm are those that have the corresponding
+ filterPktDataMask bit equal to one. The following
+ three rules are then applied to every packet:
+
+ (1) If the packet is too short and does not have data
+ corresponding to part of the filterPktData, the
+ packet will fail this data match.
+
+ (2) For each relevant bit from the packet with the
+ corresponding filterPktDataNotMask bit set to
+ zero, if the bit from the packet is not equal to
+ the corresponding bit from the filterPktData,
+ then the packet will fail this data match.
+
+ (3) If for every relevant bit from the packet with the
+ corresponding filterPktDataNotMask bit set to one,
+ the bit from the packet is equal to the
+ corresponding bit from the filterPktData, then
+ the packet will fail this data match.
+
+ Any packets that have not failed any of the three
+ matches above have passed this data match.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 4 }
+
+ filterPktDataMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The mask that is applied to the match process.
+ After adjusting this mask for the offset, only those
+ bits in the received packet that correspond to bits
+ set in this mask are relevant for further processing
+ by the match algorithm. The offset is applied to
+ filterPktDataMask in the same way it is applied to
+ the filter. For the purposes of the matching
+ algorithm, if the associated filterPktData object
+ is longer than this mask, this mask is conceptually
+ extended with '1' bits until it reaches the
+ length of the filterPktData object.
+
+
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 5 }
+
+ filterPktDataNotMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The inversion mask that is applied to the match
+ process. After adjusting this mask for the offset,
+ those relevant bits in the received packet that
+ correspond to bits cleared in this mask must all
+ be equal to their corresponding bits in the
+ filterPktData object for the packet to be accepted.
+ In addition, at least one of those relevant
+ bits in the received packet that correspond to bits
+ set in this mask must be different to its
+ corresponding bit in the filterPktData object.
+
+ For the purposes of the matching algorithm, if
+ the associated filterPktData object is longer than
+ this mask, this mask is conceptually extended with
+ '0' bits until it reaches the length of the
+ filterPktData object.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 6 }
+
+ filterPktStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status that is to be matched with the input
+ packet. The only bits relevant to this match
+ algorithm are those that have the corresponding
+ filterPktStatusMask bit equal to one.
+
+ The following two rules are then applied to every
+ packet:
+
+ (1) For each relevant bit from the packet status
+ with the corresponding filterPktStatusNotMask
+ bit set to zero, if the bit from the packet
+ status is not equal to the corresponding bit
+ from the filterPktStatus, then the packet will
+
+
+ fail this status match.
+
+ (2) If for every relevant bit from the packet status
+ with the corresponding filterPktStatusNotMask
+ bit set to one, the bit from the packet status
+ is equal to the corresponding bit from the
+ filterPktStatus, then the packet will fail
+ this status match.
+
+ Any packets that have not failed either of the two
+ matches above have passed this status match.
+
+ The value of the packet status is a sum. This sum
+ initially takes the value zero. Then, for each
+ error, E, that has been discovered in this packet,
+ 2 raised to a value representing E is added to the sum.
+ The errors and the bits that represent them are
+ dependent on the media type of the interface that
+ this channel is receiving packets from.
+
+ The errors defined for a packet captured off of an
+ Ethernet interface are as follows:
+
+ bit # Error
+ 0 Packet is longer than 1518 octets
+ 1 Packet is shorter than 64 octets
+ 2 Packet experienced a CRC or Alignment
+ error
+
+ For example, an Ethernet fragment would have a
+ value of 6 (2^1 + 2^2).
+
+ As this MIB is expanded to new media types, this
+ object will have other media-specific errors defined.
+
+ For the purposes of this status matching algorithm, if
+ the packet status is longer than this
+ object, filterPktStatus this object is conceptually
+ extended with '0' bits until it reaches the size of
+ the packet status.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 7 }
+
+ filterPktStatusMask OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "The mask that is applied to the status match process.
+ Only those bits in the received packet that correspond
+ to bits set in this mask are relevant for further
+ processing by the status match algorithm. For the
+ purposes of the matching algorithm, if the
+ associated filterPktStatus object is longer than
+ this mask, this mask is conceptually extended with
+ '1' bits until it reaches the size of the
+ filterPktStatus. In addition, if a packet status is
+ longer than this mask, this mask is conceptually
+ extended with '0' bits until it reaches the size of
+ the packet status.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 8 }
+
+ filterPktStatusNotMask OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The inversion mask that is applied to the status match
+ process. Those relevant bits in the received packet
+ status that correspond to bits cleared in this mask
+ must all be equal to their corresponding bits in the
+ filterPktStatus object for the packet to be accepted.
+ In addition, at least one of those relevant bits in the
+ received packet status that correspond to bits set in
+ this mask must be different to its corresponding bit
+ in the filterPktStatus object for the packet to be
+ accepted.
+
+ For the purposes of the matching algorithm, if the
+ associated filterPktStatus object or a packet status
+ is longer than this mask, this mask is conceptually
+ extended with '0' bits until it reaches the longer of
+ the lengths of the filterPktStatus object and the
+ packet status.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 9 }
+
+ filterOwner OBJECT-TYPE
+ SYNTAX OwnerString
+
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is
+ therefore using the resources assigned to it."
+ ::= { filterEntry 10 }
+
+ filterStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this filter entry."
+ ::= { filterEntry 11 }
+
+ channelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ChannelEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of packet channel entries."
+ ::= { filter 2 }
+
+ channelEntry OBJECT-TYPE
+ SYNTAX ChannelEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of parameters for a packet channel applied on a
+ particular interface."
+ INDEX { channelIndex }
+ ::= { channelTable 1 }
+
+ ChannelEntry ::= SEQUENCE {
+ channelIndex INTEGER (1..65535),
+ channelIfIndex INTEGER (1..65535),
+ channelAcceptType INTEGER,
+ channelDataControl INTEGER,
+ channelTurnOnEventIndex INTEGER (0..65535),
+ channelTurnOffEventIndex INTEGER (0..65535),
+ channelEventIndex INTEGER (0..65535),
+ channelEventStatus INTEGER,
+ channelMatches Counter,
+ channelDescription DisplayString (SIZE (0..127)),
+ channelOwner OwnerString,
+ channelStatus INTEGER
+ }
+
+
+
+ channelIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the channel table. Each such
+ entry defines one channel, a logical data
+ and event stream."
+ ::= { channelEntry 1 }
+
+ channelIfIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object uniquely identifies the
+ interface on this remote network monitoring device
+ to which the associated filters are applied to allow
+ data into this channel. The interface identified by
+ a particular value of this object is the same
+ interface as identified by the same value of the
+ ifIndex object, defined in [4,6]. The filters in
+ this group are applied to all packets on the local
+ network segment attached to the identified
+ interface.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 2 }
+
+ channelAcceptType OBJECT-TYPE
+ SYNTAX INTEGER {
+ acceptMatched(1),
+ acceptFailed(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls the action of the filters
+ associated with this channel. If this object is equal
+ to acceptMatched(1), packets will be accepted to this
+ channel if they are accepted by both the packet data
+ and packet status matches of an associated filter. If
+ this object is equal to acceptFailed(2), packets will
+ be accepted to this channel only if they fail either
+ the packet data match or the packet status match of
+ each of the associated filters.
+
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 3 }
+
+ channelDataControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object controls the flow of data through this
+ channel. If this object is on(1), data, status and
+ events flow through this channel. If this object is
+ off(2), data, status and events will not flow through
+ this channel."
+ DEFVAL { off }
+ ::= { channelEntry 4 }
+
+ channelTurnOnEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the event
+ that is configured to turn the associated
+ channelDataControl from off to on when the event is
+ generated. The event identified by a particular value
+ of this object is the same event as identified by the
+ same value of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then no
+ association exists. In fact, if no event is intended
+ for this channel, channelTurnOnEventIndex must be
+ set to zero, a non-existent event index.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 5 }
+
+ channelTurnOffEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the event
+ that is configured to turn the associated
+ channelDataControl from on to off when the event is
+
+
+ generated. The event identified by a particular value
+ of this object is the same event as identified by the
+ same value of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then no
+ association exists. In fact, if no event is intended
+ for this channel, channelTurnOffEventIndex must be
+ set to zero, a non-existent event index.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 6 }
+
+ channelEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (0..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The value of this object identifies the event
+ that is configured to be generated when the
+ associated channelDataControl is on and a packet
+ is matched. The event identified by a particular value
+ of this object is the same event as identified by the
+ same value of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then no
+ association exists. In fact, if no event is intended
+ for this channel, channelEventIndex must be
+ set to zero, a non-existent event index.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 7 }
+
+ channelEventStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ eventReady(1),
+ eventFired(2),
+ eventAlwaysReady(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The event status of this channel.
+
+ If this channel is configured to generate events
+ when packets are matched, a means of controlling
+ the flow of those events is often needed. When
+ this object is equal to eventReady(1), a single
+ event may be generated, after which this object
+
+
+ will be set by the probe to eventFired(2). While
+ in the eventFired(2) state, no events will be
+ generated until the object is modified to
+ eventReady(1) (or eventAlwaysReady(3)). The
+ management station can thus easily respond to a
+ notification of an event by re-enabling this object.
+
+ If the management station wishes to disable this
+ flow control and allow events to be generated
+ at will, this object may be set to
+ eventAlwaysReady(3). Disabling the flow control
+ is discouraged as it can result in high network
+ traffic or other performance problems."
+ DEFVAL { eventReady }
+ ::= { channelEntry 8 }
+
+ channelMatches OBJECT-TYPE
+ SYNTAX Counter
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of times this channel has matched a packet.
+ Note that this object is updated even when
+ channelDataControl is set to off."
+ ::= { channelEntry 9 }
+
+ channelDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..127))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A comment describing this channel."
+ ::= { channelEntry 10 }
+
+ channelOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { channelEntry 11 }
+
+ channelStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+
+
+ "The status of this channel entry."
+ ::= { channelEntry 12 }
+
+
+ -- The Packet Capture Group
+
+ -- Implementation of the Packet Capture group is optional.
+ --
+ -- The Packet Capture Group requires implementation of the
+ -- Filter Group.
+ --
+ -- The Packet Capture group allows packets to be captured
+ -- upon a filter match. The bufferControlTable controls
+ -- the captured packets output from a channel that is
+ -- associated with it. The captured packets are placed
+ -- in entries in the captureBufferTable. These entries are
+ -- associated with the bufferControlEntry on whose behalf they
+ -- were stored.
+
+ bufferControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BufferControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of buffers control entries."
+ ::= { capture 1 }
+
+ bufferControlEntry OBJECT-TYPE
+ SYNTAX BufferControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of parameters that control the collection of
+ a stream of packets that have matched filters."
+ INDEX { bufferControlIndex }
+ ::= { bufferControlTable 1 }
+
+ BufferControlEntry ::= SEQUENCE {
+ bufferControlIndex INTEGER (1..65535),
+ bufferControlChannelIndex INTEGER (1..65535),
+ bufferControlFullStatus INTEGER,
+ bufferControlFullAction INTEGER,
+ bufferControlCaptureSliceSize INTEGER,
+ bufferControlDownloadSliceSize INTEGER,
+ bufferControlDownloadOffset INTEGER,
+ bufferControlMaxOctetsRequested INTEGER,
+ bufferControlMaxOctetsGranted INTEGER,
+ bufferControlCapturedPackets INTEGER,
+
+
+ bufferControlTurnOnTime TimeTicks,
+ bufferControlOwner OwnerString,
+ bufferControlStatus INTEGER
+ }
+
+ bufferControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the bufferControl table. The value of this
+ index shall never be zero. Each such
+ entry defines one set of packets that is
+ captured and controlled by one or more filters."
+ ::= { bufferControlEntry 1 }
+
+ bufferControlChannelIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An index that identifies the channel that is the
+ source of packets for this bufferControl table.
+ The channel identified by a particular value of this
+ index is the same as identified by the same value of
+ the channelIndex object.
+
+ This object may not be modified if the associated
+ bufferControlStatus object is equal to valid(1)."
+ ::= { bufferControlEntry 2 }
+
+ bufferControlFullStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ spaceAvailable(1),
+ full(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This object shows whether the buffer has room to
+ accept new packets or if it is full.
+
+ If the status is spaceAvailable(1), the buffer is
+ accepting new packets normally. If the status is
+ full(2) and the associated bufferControlFullAction
+ object is wrapWhenFull, the buffer is accepting new
+ packets by deleting enough of the oldest packets
+
+
+ to make room for new ones as they arrive. Otherwise,
+ if the status is full(2) and the
+ bufferControlFullAction object is lockWhenFull,
+ then the buffer has stopped collecting packets.
+
+ When this object is set to full(2) the probe must
+ not later set it to spaceAvailable(1) except in the
+ case of a significant gain in resources such as
+ an increase of bufferControlOctetsGranted. In
+ particular, the wrap-mode action of deleting old
+ packets to make room for newly arrived packets
+ must not affect the value of this object."
+ ::= { bufferControlEntry 3 }
+
+ bufferControlFullAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ lockWhenFull(1),
+ wrapWhenFull(2) -- FIFO
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Controls the action of the buffer when it
+ reaches the full status. When in the lockWhenFull(1)
+ state a packet is added to the buffer that
+ fills the buffer, the bufferControlFullStatus will
+ be set to full(2) and this buffer will stop capturing
+ packets."
+ ::= { bufferControlEntry 4 }
+
+ bufferControlCaptureSliceSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of octets of each packet
+ that will be saved in this capture buffer.
+ For example, if a 1500 octet packet is received by
+ the probe and this object is set to 500, then only
+ 500 octets of the packet will be stored in the
+ associated capture buffer. If this variable is set
+ to 0, the capture buffer will save as many octets
+ as is possible.
+
+ This object may not be modified if the associated
+ bufferControlStatus object is equal to valid(1)."
+ DEFVAL { 100 }
+ ::= { bufferControlEntry 5 }
+
+
+ bufferControlDownloadSliceSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of octets of each packet
+ in this capture buffer that will be returned in
+ an SNMP retrieval of that packet. For example,
+ if 500 octets of a packet have been stored in the
+ associated capture buffer, the associated
+ bufferControlDownloadOffset is 0, and this
+ object is set to 100, then the captureBufferPacket
+ object that contains the packet will contain only
+ the first 100 octets of the packet.
+
+ A prudent manager will take into account possible
+ interoperability or fragmentation problems that may
+ occur if the download slice size is set too large.
+ In particular, conformant SNMP implementations are not
+ required to accept messages whose length exceeds 484
+ octets, although they are encouraged to support larger
+ datagrams whenever feasible."
+ DEFVAL { 100 }
+ ::= { bufferControlEntry 6 }
+
+ bufferControlDownloadOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The offset of the first octet of each packet
+ in this capture buffer that will be returned in
+ an SNMP retrieval of that packet. For example,
+ if 500 octets of a packet have been stored in the
+ associated capture buffer and this object is set to
+ 100, then the captureBufferPacket object that
+ contains the packet will contain bytes starting
+ 100 octets into the packet."
+ DEFVAL { 0 }
+ ::= { bufferControlEntry 7 }
+
+ bufferControlMaxOctetsRequested OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The requested maximum number of octets to be
+ saved in this captureBuffer, including any
+
+
+ implementation-specific overhead. If this variable
+ is set to -1, the capture buffer will save as many
+ octets as is possible.
+
+ When this object is created or modified, the probe
+ should set bufferControlMaxOctetsGranted as closely
+ to this object as is possible for the particular probe
+ implementation and available resources. However, if
+ the object has the special value of -1, the probe
+ must set bufferControlMaxOctetsGranted to -1."
+ DEFVAL { -1 }
+ ::= { bufferControlEntry 8 }
+
+ bufferControlMaxOctetsGranted OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum number of octets that can be
+ saved in this captureBuffer, including overhead.
+ If this variable is -1, the capture buffer will save
+ as many octets as possible.
+
+ When the bufferControlMaxOctetsRequested object is
+ created or modified, the probe should set this object
+ as closely to the requested value as is possible for
+ the particular probe implementation and available
+ resources. However, if the request object has the
+ special value of -1, the probe must set this object
+ to -1. The probe must not lower this value except
+ as a result of a modification to the associated
+ bufferControlMaxOctetsRequested object.
+
+ When this maximum number of octets is reached
+ and a new packet is to be added to this
+ capture buffer and the corresponding
+ bufferControlFullAction is set to wrapWhenFull(2),
+ enough of the oldest packets associated with this
+ capture buffer shall be deleted by the agent so
+ that the new packet can be added. If the
+ corresponding bufferControlFullAction is set to
+ lockWhenFull(1), the new packet shall be discarded.
+ In either case, the probe must set
+ bufferControlFullStatus to full(2).
+
+ When the value of this object changes to a value less
+ than the current value, entries are deleted from
+ the captureBufferTable associated with this
+
+
+ bufferControlEntry. Enough of the
+ oldest of these captureBufferEntries shall be
+ deleted by the agent so that the number of octets
+ used remains less than or equal to the new value of
+ this object.
+
+ When the value of this object changes to a value greater
+ than the current value, the number of associated
+ captureBufferEntries may be allowed to grow."
+ ::= { bufferControlEntry 9 }
+
+ bufferControlCapturedPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of packets currently in this captureBuffer."
+ ::= { bufferControlEntry 10 }
+
+ bufferControlTurnOnTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime when this capture buffer was
+ first turned on."
+ ::= { bufferControlEntry 11 }
+
+ bufferControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { bufferControlEntry 12 }
+
+ bufferControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this buffer Control Entry."
+ ::= { bufferControlEntry 13 }
+
+ captureBufferTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CaptureBufferEntry
+ ACCESS not-accessible
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "A list of packets captured off of a channel."
+ ::= { capture 2 }
+
+ captureBufferEntry OBJECT-TYPE
+ SYNTAX CaptureBufferEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A packet captured off of an attached network."
+ INDEX { captureBufferControlIndex, captureBufferIndex }
+ ::= { captureBufferTable 1 }
+
+ CaptureBufferEntry ::= SEQUENCE {
+ captureBufferControlIndex INTEGER (1..65535),
+ captureBufferIndex INTEGER,
+ captureBufferPacketID INTEGER,
+ captureBufferPacketData OCTET STRING,
+ captureBufferPacketLength INTEGER,
+ captureBufferPacketTime INTEGER,
+ captureBufferPacketStatus INTEGER
+ }
+
+ captureBufferControlIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the bufferControlEntry with which
+ this packet is associated."
+ ::= { captureBufferEntry 1 }
+
+ captureBufferIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the captureBuffer table associated with a
+ particular bufferControlEntry. This index will
+ start at 1 and increase by one for each new packet
+ added with the same captureBufferControlIndex."
+ ::= { captureBufferEntry 2 }
+
+ captureBufferPacketID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+
+
+ STATUS mandatory
+ DESCRIPTION
+ "An index that describes the order of packets
+ that are received on a particular interface.
+ The packetID of a packet captured on an
+ interface is defined to be greater than the
+ packetID's of all packets captured previously on
+ the same interface. As the captureBufferPacketID
+ object has a maximum positive value of 2^31 - 1,
+ any captureBufferPacketID object shall have the
+ value of the associated packet's packetID mod 2^31."
+ ::= { captureBufferEntry 3 }
+
+ captureBufferPacketData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The data inside the packet, starting at the beginning
+ of the packet plus any offset specified in the
+ associated bufferControlDownloadOffset, including any
+ link level headers. The length of the data in this
+ object is the minimum of the length of the captured
+ packet minus the offset, the length of the associated
+ bufferControlCaptureSliceSize minus the offset, and the
+ associated bufferControlDownloadSliceSize. If this
+ minimum is less than zero, this object shall have a
+ length of zero."
+ ::= { captureBufferEntry 4 }
+
+ captureBufferPacketLength OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The actual length (off the wire) of the packet stored
+ in this entry, including FCS octets."
+ ::= { captureBufferEntry 5 }
+
+ captureBufferPacketTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of milliseconds that had passed since
+ this capture buffer was first turned on when this
+ packet was captured."
+ ::= { captureBufferEntry 6 }
+
+
+ captureBufferPacketStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A value which indicates the error status of this
+ packet.
+
+ The value of this object is defined in the same way as
+ filterPacketStatus. The value is a sum. This sum
+ initially takes the value zero. Then, for each
+ error, E, that has been discovered in this packet,
+ 2 raised to a value representing E is added to the sum.
+
+ The errors defined for a packet captured off of an
+ Ethernet interface are as follows:
+
+ bit # Error
+ 0 Packet is longer than 1518 octets
+ 1 Packet is shorter than 64 octets
+ 2 Packet experienced a CRC or Alignment
+ error
+ 3 First packet in this capture buffer after
+ it was detected that some packets were
+ not processed correctly.
+
+ For example, an Ethernet fragment would have a
+ value of 6 (2^1 + 2^2).
+
+ As this MIB is expanded to new media types, this object
+ will have other media-specific errors defined."
+ ::= { captureBufferEntry 7 }
+
+
+ -- The Event Group
+
+ -- Implementation of the Event group is optional.
+ --
+ -- The Event group controls the generation and notification
+ -- of events from this device. Each entry in the eventTable
+ -- describes the parameters of the event that can be triggered.
+ -- Each event entry is fired by an associated condition located
+ -- elsewhere in the MIB. An event entry may also be associated
+ -- with a function elsewhere in the MIB that will be executed
+ -- when the event is generated. For example, a channel may
+ -- be turned on or off by the firing of an event.
+ --
+ -- Each eventEntry may optionally specify that a log entry
+
+
+ -- be created on its behalf whenever the event occurs.
+ -- Each entry may also specify that notification should
+ -- occur by way of SNMP trap messages. In this case, the
+ -- community for the trap message is given in the associated
+ -- eventCommunity object. The enterprise and specific trap
+ -- fields of the trap are determined by the condition that
+ -- triggered the event. Three traps are defined in a companion
+ -- document: risingAlarm, fallingAlarm, and packetMatch.
+ -- If the eventTable is triggered by a condition specified
+ -- elsewhere, the enterprise and specific trap fields
+ -- must be specified for traps generated for that condition.
+
+ eventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of events to be generated."
+ ::= { event 1 }
+
+ eventEntry OBJECT-TYPE
+ SYNTAX EventEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of parameters that describe an event to be
+ generated when certain conditions are met."
+ INDEX { eventIndex }
+ ::= { eventTable 1 }
+
+ EventEntry ::= SEQUENCE {
+ eventIndex INTEGER (1..65535),
+ eventDescription DisplayString (SIZE (0..127)),
+ eventType INTEGER,
+ eventCommunity OCTET STRING (SIZE (0..127)),
+ eventLastTimeSent TimeTicks,
+ eventOwner OwnerString,
+ eventStatus INTEGER
+ }
+
+ eventIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ event table. Each such entry defines one event that
+ is to be generated when the appropriate conditions
+
+
+ occur."
+ ::= { eventEntry 1 }
+
+ eventDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..127))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A comment describing this event entry."
+ ::= { eventEntry 2 }
+
+ eventType OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ log(2),
+ snmp-trap(3), -- send an SNMP trap
+ log-and-trap(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The type of notification that the probe will make
+ about this event. In the case of log, an entry is
+ made in the log table for each event. In the case of
+ snmp-trap, an SNMP trap is sent to one or more
+ management stations."
+ ::= { eventEntry 3 }
+
+ eventCommunity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..127))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "If an SNMP trap is to be sent, it will be sent to
+ the SNMP community specified by this octet string.
+ In the future this table will be extended to include
+ the party security mechanism. This object shall be
+ set to a string of length zero if it is intended that
+ that mechanism be used to specify the destination of
+ the trap."
+ ::= { eventEntry 4 }
+
+ eventLastTimeSent OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime at the time this event
+
+
+ entry last generated an event. If this entry has
+ not generated any events, this value will be
+ zero."
+ ::= { eventEntry 5 }
+
+ eventOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it.
+
+ If this object contains a string starting with 'monitor'
+ and has associated entries in the log table, all
+ connected management stations should retrieve those
+ log entries, as they may have significance to all
+ management stations connected to this device"
+ ::= { eventEntry 6 }
+
+ eventStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this event entry.
+
+ If this object is not equal to valid(1), all associated
+ log entries shall be deleted by the agent."
+ ::= { eventEntry 7 }
+
+ --
+ logTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LogEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of events that have been logged."
+ ::= { event 2 }
+
+ logEntry OBJECT-TYPE
+ SYNTAX LogEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A set of data describing an event that has been
+ logged."
+ INDEX { logEventIndex, logIndex }
+
+
+ ::= { logTable 1 }
+
+ LogEntry ::= SEQUENCE {
+ logEventIndex INTEGER (1..65535),
+ logIndex INTEGER,
+ logTime TimeTicks,
+ logDescription DisplayString (SIZE (0..255))
+ }
+
+ logEventIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..65535)
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The event entry that generated this log
+ entry. The log identified by a particular
+ value of this index is associated with the same
+ eventEntry as identified by the same value
+ of eventIndex."
+ ::= { logEntry 1 }
+
+ logIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the log table amongst those generated by the
+ same eventEntries. These indexes are
+ assigned beginning with 1 and increase by one
+ with each new log entry. The association
+ between values of logIndex and logEntries
+ is fixed for the lifetime of each logEntry.
+ The agent may choose to delete the oldest
+ instances of logEntry as required because of
+ lack of memory. It is an implementation-specific
+ matter as to when this deletion may occur."
+ ::= { logEntry 2 }
+
+ logTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of sysUpTime when this log entry was
+ created."
+ ::= { logEntry 3 }
+
+
+
+ logDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An implementation dependent description of the
+ event that activated this log entry."
+ ::= { logEntry 4 }
+
+ END
+