Age | Commit message (Collapse) | Author |
|
|
|
|
|
* sal/ftp/OTP-10886:
Changed to correct errorcode in testcase
Handle correctly the "No files found or file unavailable" error code.
|
|
|
|
httpc: CTfy test suite
httpd: Simplify ssl configuration OTP-10846
|
|
OTP-10844
|
|
OTP-10845
|
|
|
|
|
|
|
|
|
|
* hsv/http_redirect_on_post_303/OTP-10765:
inets: fix autoredirect for POST requests responding 303
inets - httpc_SUITE: add redirect tests for response 303
|
|
|
|
|
|
* nox/enable-silent-rules/OTP-10726:
Implement ./otp_build configure --enable-silent-rules
|
|
Changed httpc_response, for redirect '303 See Other' also POST
requests should be redirected (using GET). See RFC2616 sect. 10.3.4
for clarification.
|
|
httpc contains code for redirecting http response
301, 302, 303, and 307, but no tests existed for
response '303 See Other'. Added tests (get, head, and post)
for 303 and renumbered tests for 307. The subtle thing is that
for 303 also post requests *should* be redirected.
Also added the necessary 303 page to the dummy_server.
|
|
With silent rules, the output of make is less verbose and compilation
warnings are easier to spot. Silent rules are disabled by default and
can be disabled or enabled at will by make V=0 and make V=1.
|
|
Examples overflowing the width of PDF pages have been fixed.
The remaining warnings are due to table cells, and require more
work.
|
|
The R15B03 release
|
|
|
|
* bjorn/asn1/clean-up-backends/OTP-10410:
Simplify the code for the generated info/0 function
Don't try to work around a non-loadable NIF library
Fix BER encoding when multiple levels of typedefs are used
Update megaco documentation
Update documentation for the asn1 application
Fix other applications
Fix use of asn1 in megaco
Remove the unused asn1ct_gen_ber module
Remove the unused asn1ct_constructed_ber module
Remove the unused asn1ct_per_bin module
Remove unused functions in asn1rt_ber_bin
Remove obsolete back-ends and simplify the options
Make the specialized decodes work with the 'nif' option
Remove support for the obsolete {Typename,Value} tuple notation
Remove tests for the obsolete {TypeName,Value} notation
Remove the obsolete and deprecated 'keyed_list' option
|
|
|
|
|
|
|
|
* maint:
Increased waiting time to check if socket is down
Fine adjustments of slowdos alg
Changes to slowdos testcase
Doc for test case slowdose
Bumped version nr
Added testcases för minimum_bytes_per_second option
Reduced checking of bytes per second to every second
Documentation for minimum_bytes_per_seconds option
Changed property to minimum_bytes_per_second and checking if is integer on start
Changed to Bytes Per Second when checking clients rate, new options {byte_limit, integer()}
Option {bit_limit, integer()} to close sockets where clients are too slow
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
{byte_limit, integer()}
|
|
|
|
* maint:
Skip ct_netconf tests if there is no crypto
Migrate timers from test_server to ct interface
Update tests to run with an oldshell emulator
Move crypto check so that tc is skipped and not failed
Update for new version of ppc compilation chain
Verify that ebin folder of applications exists
Conflicts:
lib/asn1/test/asn1_SUITE.erl
lib/kernel/test/interactive_shell_SUITE.erl
|
|
|
|
|
|
|
|
* raimo/inets/https-proxy/OTP-10256:
inets httpc: Document that RFC 2817 is not supported
inets: Dialyzer fixes
inets httpc: TLS via proxy
inets: Remove obsolete testcases that are now in the proxy suite
inets: Add tests using external proxy running on localhost
|
|
|
|
|
|
Introduces new option htts_proxy so that it is possible
to have different proxies for http and https. The new option
defaults to the old proxy option.
Implements HTTP-1.1 extension method CONNECT to establish SSL/TLS tunnel
We choose not to implement "TLS upgrade" as defined by RFC 2817 as
this method of upgrade is vulnerable to man in the middle attacks,
can be easily broken by proxies and does not seem to be widely adopted.
|
|
|
|
|
|
Conflicts:
lib/diameter/autoconf/vxworks/sed.general
xcomp/README.md
|
|
|
|
* upstream/maint:
ssh: Increase robustness
inets: Dialyzer spec fixes
|