Age | Commit message (Collapse) | Author |
|
I did not find any legitimate use of "can not", however skipped
changing e.g RFCs archived in the source tree.
|
|
|
|
|
|
In order to test that unicode paths can be used in release handling,
the release_handler_SUITE will use a priv_dir with unicode characters
if the file name translation mode is utf8 (not on windows).
|
|
|
|
Release_handler_suite correctly checks that no calls to the file module
is done during a diskless upgrade, but file:native_name_encoding is
a BIF that does no real i/o and can therefore be called during command line
argunemt parsing. The testcase is updated to ignore such calls.
|
|
This is an attempt to correct a failing test case. It the test fails
on having restarted only once, we give it another try to see if the
second restart will happen.
|
|
If the version of erts differs between two releases, the release
handler automatically adds a 'restart_new_emulator' instruction to the
upgrade script (relup). Earlier, this instruction was always added at
the end of the upgrade script, causing the following sequence of
operations during an upgrade (a bit simplified):
1. suspend processes
2. load new code
3. execute code_change functions
4. resume processes
5. restart emulator with new erts version
Obviously, this caused the new code to be loaded into the old emulator
and this would fail if the beam format had been changed in the new
version of the emulator.
To overcome this problem, this commit changes the order of the
instructions, so for upgrade with changed erts version we now have:
1. restart emulator with new erts, kernel, stdlib and sasl versions,
but old versions of all other applications.
2. suspend processes
3. load new code
4. execute code_change functions
5. resume processes
This is implemented by creating a temporary release, including new
erts, kernel, stdlib and sasl from the new release and all other
applications from the old release. A new boot file for this temporary
release is created, which includes a new 'apply' instruction to run
release_handler:new_emulator_upgrade/2. Then the emulator is restarted
using this boot file - and release_handler:new_emulator_upgrade/2
executes the rest of the upgrade script.
For downgrade, the order will be as before:
1. suspend processes
2. execute code_change functions with 'down'-indication
3. load old code
4. resume processes
5. restart emulator with old erts version
|
|
The service will automatically use the start_erl.exe from the same
directory as erlsrv.exe, and heart will use $PATH, which will
always have the erts bin dir first. The reason is to avoid using old
executables after upgrading erts via the release_handler.
|
|
This commit adds test cases from release_handler_SUITE on windows,
including some corrections in erlsrv and release_handler.
|
|
|