Age | Commit message (Collapse) | Author |
|
|
|
|
|
|
|
* bjorn/asn1/misc-bug-fixes/OTP-12125:
Workaround for combining two object sets separated by extension
Clean up and correct handling of parameters for parameterized types
Check the formal parameter for parameterized type definitions
Report errors also for unused parameterized types
Remove unused code for ABSTRACT-SYNTAX and TYPE-IDENTIFIER
Correct expansion of parameterized types
Add the module name to the #classdef{} record
Eliminate the use of #identifier{} outside the tokeniser and parser
Fix problem with object identifiers in external modules
Rewrite get_referenced_type/2
Teach the ASN.1 compiler to handle objects in field names
Teach the ASN.1 compiler to understand "EXPORTS ALL"
Teach the ASN.1 compiler the parse option
|
|
* bjorn/asn1/decoding-robustness/OTP-12145:
BER decoding: Improve error checking for indefinite length
BER: Test decoding of indefinite lengths
|
|
maint
* lucafavatella/improve-cpu_sup-error-when-slow-port-init:
Clarify error for slow `cpu_sup` port init
|
|
|
|
* ia/public_key/utf8-doc:
public_key: Correct documentation of ASN-1 type utf8String
|
|
|
|
* egil/fix-llvm-cc-warnings/OTP-12138:
odbc: Suppress signedness warnings for 'char *'
ic: Suppress unused-value warning
erts: Fix tentative-definition-incomplete-type
erts: Don't redefine '_XOPEN_SOURCE'
|
|
* egil/maps-with-doc-tests/OTP-12137:
stdlib: Test maps:with/2
stdlib: Document maps:with/2
|
|
* arekinath/ssh/aes-ctr:
ssh: check if ssh client supports newer cipher- and MAC-algorithms
SSH: only enable ciphers/MACs when they are available in crypto
SSH: add ssh_to_openssh test for ciphers and macs
SSH: documentation update for new algos
SSH: add support for aes128-ctr and hmac-sha2-256
|
|
|
|
|
|
|
|
|
|
|
|
This module may change without warning...
|
|
|
|
The following type of code would crash the compiler:
OSET SOME-CLASS ::= {OSET1, ..., OSET2}
|
|
The previous code looked at the actual parameters supplied when
instantiating the type to determine the type of the argument; the
correct way is to determine the type by looking at the governor and
case of the formal parameter.
|
|
Check the formal parameters for a parameterized type definition.
If the governor for a formal parameter is absent, the formal parameter
must be in upper case.
|
|
Definitions for parameterized types are verified once very early,
and one more time when they are instantiated.
Errors found during the first check were ignored, so errors for
unused parameterized types were not reported.
|
|
Before classes were fully implemented, there was support for
ABSTRACT-SYNTAX and TYPE-IDENTIFIER. Some of that code is still
there and is no longer used. Get rid of it and correct comments.
|
|
Attempting to compile:
SomeType{SOME-CLASS-NAME, SOME-CLASS-NAME:SomeSet} ::= ...
SEQUENCE {
something SOME-CLASS-NAME.&id({SomeSet})
}
would crash the compiler, because the actual parameter for
SOME-CLASS-NAME was not substituted into the governor for
the SomeSet parameter.
While we are at it, combine the functionality of is_class/2
and get_class_def/2 (eliminating is_class/2). Most callers
call both function.
|
|
If we want construct an #'Externaltypereference'{} from
a #classdef{} record, we will need the module name.
|
|
The only remaining use of #identifier{} in asn1ct_check was in a
temporary packaging of a value that would be ultimately be put
into #valuedef{}.
Therefore we can eliminate that last usage but putting the value
directly into a #valuedef{} and we can move the record definition
into asn1ct_parser2.
|
|
When parsing ASN.1, certain constructs can only be understood in
the full context of the entire ASN.1 module.
For instance, the value following ID in this simplified excerpt
from MTSAbstractService88:
administration-88 PORT ::= {
ID {id-pt-administration 88}
}
the value following "ID" can be interpreted either as value
for:
SEQUENCE {
id-pt-administration INTEGER
}
or as an OBJECT IDENTIFIER.
Our ASN.1 parser assumes that a SEQUENCE is meant, and if that
later turns out to be wrong, the SEQUENCE value is rewritten to
an OBJECT IDENTIFIER. The problem is that at the time of the
rewrite, we no longer know in which ASN.1 module id-pt-administration
was defined in, and we have to use the module name in the state{}
record. Unfortunately, the module name in the state{} record may
not always be correct.
While there are attempts in the code to keep the module name
up-to-date when checking imported types, it is not done consistently,
and it seems to be a difficult and error-prone task to attempt
to make it consistent.
A safer and less error-prone approach is to make sure that we
don't lose the module name while parsing. To make it clear what
we are doing, we will introduce a new #seqtag{} record that
are used for tags in SEQUENCE values. The name is based on its
primary use. The record also contains the module in case it happens
to be an OBJECT IDENTIFIER.
|
|
Make sure that we continue to follow external references until
we find a real type.
|
|
|
|
EXPORTS ALL is the same as leaving out the EXPORTS statement.
|
|
|
|
* bjorn/compiler/fix-scope-bug/OTP-12132:
sys_core_fold: Eliminate name capture bug
|
|
The scope is supposed to contain all variables that are currently
live. We need this information for certain optimizations to
avoid capturing a name (a name that is in the scope must be renamed;
for an example, see move_let_into_expr/2 or any function that calls
sub_subst_scope/1). We also use the scope to optimize sub_del_var/2
and sub_is_val/2.
When optimizing case expressions, the scope could be reset to an
empty list (because sub_new/0 was called instead of sub_new/1).
That could cause name capture if inlining was turned on.
As simple way to force this bug is to uncomment the
"-define(DEBUG, 1)." near the beginning of the file. Without this
correction, most files in the test suite fail to compile.
|
|
* nox/erl_scan-fix-column-tracking:
Properly track column numbers in erl_scan
|
|
* siri/ct-runtime-deps/OTP-12037:
[ct] Update runtime dependencies towards test_server
|
|
Conflicts:
OTP_VERSION
|
|
I noticed that running an R16B03-1 node on an overloaded host produced
log entries like the following ones:
```
2014-08-22 21:52:31 =ERROR REPORT====
Error in process <0.24112.3> on node '[email protected]' with exit value: {{case_clause,{data,4711}},[{cpu_sup,get_uint32_measurement,2,[{file,"cpu_sup.erl"},{line,227}]},{cpu_sup,measurement_server_loop,1,[{file,"cpu_sup.erl"},{line,585}]}]}
```
```
===== ALIVE Fri Aug 22 21:50:14 CEST 2014
[os_mon] cpu supervisor port (cpu_sup): Erlang has closed
[os_mon] cpu supervisor port (cpu_sup): Erlang has closed
[os_mon] cpu supervisor port (cpu_sup): Erlang has closed
[os_mon] cpu supervisor port (cpu_sup): Erlang has closed
===== ALIVE Fri Aug 22 22:07:46 CEST 2014
```
I performed a code inspection on the `cpu_sup` module and I concluded
that the `case_clause` error shows a small issue in the `cpu_sup`
module, that happens when the port used in `cpu_sup` is slow to start
- as it may happen on an overloaded node.
The `cpu_sup` `gen_server` process keeps in its state the pid of an
unlinked process (called "measurement server" - see `cpu_sup:init/1`),
in order to do dirty stuff (e.g. reading the filesystem, running OS
commands) and start_link-ing & managing the connected process to a
port (called "port server" - see `measurement_server_init/0`). So the
process organization looks like this:
```
cpu_sup - measurement server - port server - port
```
When the measurement server start_links the port server (see
`port_server_start/0`) it sends a `{self(), ?ping}` message to it and
expects an answer within 6s, otherwise it returns `{error, timeout}`
rather than the pid. This has two issues:
* The measurement server keeps `{error, ...}` in its state as if it
were a pid - that makes no sense;
* A late `{Pid, {data,4711}}` response may arrive in the mailbox of
the measurement server, that will believe it to be a request to be
processed, causing a `case_clause` error.
This commit teaches the measurement server to check the success of the
initialization of the port server by matching on the return value of
`port_server_start/0` (renamed to `port_server_start_link/0` for the
sake of clarity) in order to fail earlier and with an error clearer
than `{case_clause,{data,4711}}`. In such case I expect the
measurement server to be restarted by the `cpu_sup` `gen_server` (see
`handle_call/3`) - as before.
BTW It is not clear to me when the `handle_info({'EXIT', _Port,
Reason}, State)` may be called (the `cpu_sup` `gen_server` does not
link to the measurement server) but I am leaving it.
|
|
* ia/public_key/dialyzer:
public_key: Fix spec and documentation for pkix_crls_validate
public_key: Fix spec and documentation for PBES
|
|
|
|
* dgud/stdlib/format_status_terminate/OTP-11967:
stdlib: Call format_status even if terminate callback crashes
|
|
* michaelkschmidt/ssh_bug_fix:
Test Other Clauses of start_shell
Fix SSH CLI when using custom "shell" option
|
|
* tuncer/misspelled-another:
Fix misspellings of 'another'
|
|
By doing an abort, the create_table can be restarted
if a node go down during the transaction.
{badarg,
[{erlang,link,[undefined],[]},
{mnesia_controller,
wait_for_schema_commit_lock,0,
[{file,"mnesia_controller.erl"},
{line,303}]},
{mnesia_schema,prepare_commit,3,
[{file,"mnesia_schema.erl"},
{line,1838}]},
{mnesia_tm,commit_participant,6,
[{file,"mnesia_tm.erl"},
{line,1669}]}]}}},
|
|
Also adjusts tests to only expect a positive outcome when
crypto supports the relevant base ciphers/MACs.
|
|
|
|
|
|
* lpgauth/fix_httpc_doc_typo:
Fix typo in documentation /header_as_is/headers_as_is/
|
|
* ia/odbc/win-test:
odbc: Condition test case to avoid permission issues in Vista
|
|
|