1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
|
<?xml version="1.0" encoding="latin1" ?>
<!DOCTYPE chapter SYSTEM "chapter.dtd">
<chapter>
<header>
<copyright>
<year>2006</year><year>2012</year>
<holder>Ericsson AB. All Rights Reserved.</holder>
</copyright>
<legalnotice>
The contents of this file are subject to the Erlang Public License,
Version 1.1, (the "License"); you may not use this file except in
compliance with the License. You should have received a copy of the
Erlang Public License along with this software. If not, it can be
retrieved online at http://www.erlang.org/.
Software distributed under the License is distributed on an "AS IS"
basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See
the License for the specific language governing rights and limitations
under the License.
</legalnotice>
<title>Event Handling</title>
<prepared>Peter Andersson</prepared>
<docno></docno>
<date></date>
<rev></rev>
<file>event_handler_chapter.xml</file>
</header>
<section>
<marker id="event_handling"></marker>
<title>General</title>
<p>It is possible for the operator of a Common Test system to receive
event notifications continously during a test run. It is reported e.g.
when a test case starts and stops, what the current count of successful,
failed and skipped cases is, etc. This information can be used for
different purposes such as logging progress and results on
other format than HTML, saving statistics to a database for report
generation and test system supervision.</p>
<p>Common Test has a framework for event handling which is based on
the OTP event manager concept and gen_event behaviour. When the Common Test
server starts, it spawns an event manager. During test execution the
manager gets a notification from the server every time something
of potential interest happens. Any event handler plugged into the
event manager can match on events of interest, take action, or maybe
simply pass the information on. Event handlers are Erlang modules
implemented by the Common Test user according to the gen_event
behaviour (see the OTP User's Guide and Reference Manual for more
information).</p>
<p>As already described, a Common Test server always starts an event manager.
The server also plugs in a default event handler which has as its only
purpose to relay notifications to a globally registered CT Master
event manager (if a CT Master server is running in the system).
The CT Master also spawns an event manager at startup.
Event handlers plugged into this manager will receive the events from
all the test nodes as well as information from the CT Master server
itself.</p>
</section>
<section>
<marker id="usage"></marker>
<title>Usage</title>
<p>Event handlers may be installed by means of an <c>event_handler</c>
start flag (<c>ct_run</c>) or option (<seealso marker="ct#run_test-1"><c>ct:run_test/1</c></seealso>), where the
argument specifies the names of one or more event handler modules.
Example:</p>
<p><c>$ ct_run -suite test/my_SUITE -event_handler handlers/my_evh1
handlers/my_evh2 -pa $PWD/handlers</c></p>
<p>Use the <c><![CDATA[ct_run -event_handler_init]]></c> option instead of
<c><![CDATA[-event_handler]]></c> to pass start arguments to the event handler
init function.</p>
<p>All event handler modules must have gen_event behaviour. Note also that
these modules must be precompiled, and that their locations must be
added explicitly to the Erlang code server search path (like in the
example).</p>
<p>An event_handler tuple in the argument <c>Opts</c> has the following
definition (see also <seealso marker="ct#run_test-1"><c>ct:run_test/1</c></seealso> in the reference manual):</p>
<pre>
{event_handler,EventHandlers}
EventHandlers = EH | [EH]
EH = atom() | {atom(),InitArgs} | {[atom()],InitArgs}
InitArgs = [term()]</pre>
<p>Example:</p>
<pre>
1> ct:run_test([{suite,"test/my_SUITE"},{event_handler,[my_evh1,{my_evh2,[node()]}]}]).</pre>
<p>This will install two event handlers for the <c>my_SUITE</c> test. Event handler
<c>my_evh1</c> is started with <c>[]</c> as argument to the init function. Event handler
<c>my_evh2</c> is started with the name of the current node in the init argument list.</p>
<p>Event handlers can also be plugged in by means of
<seealso marker="run_test_chapter#test_specifications">test specification</seealso>
terms:</p>
<p><c>{event_handler, EventHandlers}</c>, or</p>
<p><c>{event_handler, EventHandlers, InitArgs}</c>, or</p>
<p><c>{event_handler, NodeRefs, EventHandlers}</c>, or</p>
<p><c>{event_handler, NodeRefs, EventHandlers, InitArgs}</c></p>
<p><c>EventHandlers</c> is a list of module names. Before a test
session starts, the init function of each plugged in event handler
is called (with the InitArgs list as argument or [] if
no start arguments are given).</p>
<p>To plug a handler into the CT Master event manager, specify
<c>master</c> as the node in <c>NodeRefs</c>.</p>
<p>For an event handler to be able to match on events, the module must
include the header file <c>ct_event.hrl</c>. An event is a record with the
following definition:</p>
<p><c>#event{name, node, data}</c></p>
<p><c>name</c> is the label (type) of the event. <c>node</c> is the name of the
node the event has originated from (only relevant for CT Master event handlers).
<c>data</c> is specific for the particular event.</p>
<marker id="events"></marker>
<p><em>General events:</em></p>
<list>
<item><c>#event{name = start_logging, data = LogDir}</c>
<p><c>LogDir = string()</c>, top level log directory for the test run.</p>
<p>Indicates that the logging process of Common Test
has started successfully and is ready to receive IO
messages.</p></item>
<item><c>#event{name = stop_logging, data = []}</c>
<p>Indicates that the logging process of Common Test
has been shut down at the end of the test run.
</p></item>
<item><c>#event{name = test_start, data = {StartTime,LogDir}}</c>
<p><c>StartTime = {date(),time()}</c>, test run start date and time.</p>
<p><c>LogDir = string()</c>, top level log directory for the test run.</p>
<p>This event indicates that Common Test has finished initial preparations
and will begin executing test cases.
</p></item>
<item><c>#event{name = test_done, data = EndTime}</c>
<p><c>EndTime = {date(),time()}</c>, date and time the test run finished.</p>
<p>This indicates that the last test case has been executed and
Common Test is shutting down.
</p></item>
<item><c>#event{name = start_info, data = {Tests,Suites,Cases}}</c>
<p><c>Tests = integer()</c>, the number of tests.</p>
<p><c>Suites = integer()</c>, the total number of suites.</p>
<p><c>Cases = integer() | unknown</c>, the total number of test cases.</p>
<p>Initial test run information that can be interpreted as: "This test
run will execute <c>Tests</c> separate tests, in total containing
<c>Cases</c> number of test cases, in <c>Suites</c> number of suites".
Note that if a test case group with a repeat property exists in any test,
the total number of test cases can not be calculated (unknown).
</p></item>
<item><c>#event{name = tc_start, data = {Suite,FuncOrGroup}}</c>
<p><c>Suite = atom()</c>, name of the test suite.</p>
<p><c>FuncOrGroup = Func | {Conf,GroupName,GroupProperties}</c></p>
<p><c>Func = atom()</c>, name of test case or configuration function.</p>
<p><c>Conf = init_per_group | end_per_group</c>, group configuration function.</p>
<p><c>GroupName = atom()</c>, name of the group.</p>
<p><c>GroupProperties = list()</c>, list of execution properties for the group.</p>
<p>This event informs about the start of a test case, or a group configuration
function. The event is sent also for <c>init_per_suite</c> and <c>end_per_suite</c>,
but not for <c>init_per_testcase</c> and <c>end_per_testcase</c>. If a group
configuration function is starting, the group name and execution properties
are also given.
</p></item>
<item><c>#event{name = tc_logfile, data = {{Suite,Func},LogFileName}}</c>
<p><c>Suite = atom()</c>, name of the test suite.</p>
<p><c>Func = atom()</c>, name of test case or configuration function.</p>
<p><c>LogFileName = string()</c>, full name of test case log file.</p>
<p>This event is sent at the start of each test case (and configuration function
except <c>init/end_per_testcase</c>) and carries information about the
full name (i.e. the file name including the absolute directory path) of
the current test case log file.
</p></item>
<marker id="tc_done"/>
<item><c>#event{name = tc_done, data = {Suite,FuncOrGroup,Result}}</c>
<p><c>Suite = atom()</c>, name of the suite.</p>
<p><c>FuncOrGroup = Func | {Conf,GroupName,GroupProperties}</c></p>
<p><c>Func = atom()</c>, name of test case or configuration function.</p>
<p><c>Conf = init_per_group | end_per_group</c>, group configuration function.</p>
<p><c>GroupName = unknown | atom()</c>, name of the group
(unknown if init- or end function times out).</p>
<p><c>GroupProperties = list()</c>, list of execution properties for the group.</p>
<p><c>Result = ok | {skipped,SkipReason} | {failed,FailReason}</c>, the result.</p>
<marker id="skipreason"/>
<p><c>SkipReason = {require_failed,RequireInfo} |
{require_failed_in_suite0,RequireInfo} |
{failed,{Suite,init_per_testcase,FailInfo}} |
UserTerm</c>,
the reason why the case has been skipped.</p>
<marker id="failreason"/>
<p><c>FailReason = {error,FailInfo} |
{error,{RunTimeError,StackTrace}} |
{timetrap_timeout,integer()} |
{failed,{Suite,end_per_testcase,FailInfo}}</c>, reason for failure.</p>
<p><c>RequireInfo = {not_available,atom() | tuple()}</c>, why require has failed.</p>
<p><c>FailInfo = {timetrap_timeout,integer()} |
{RunTimeError,StackTrace} |
UserTerm</c>,
detailed information about an error.</p>
<p><c>RunTimeError = term()</c>, a run-time error, e.g. badmatch, undef, etc.</p>
<p><c>StackTrace = list()</c>, list of function calls preceeding a run-time error.</p>
<p><c>UserTerm = term()</c>, arbitrary data specified by user, or <c>exit/1</c> info.</p>
<p>This event informs about the end of a test case or a configuration function (see the
<c>tc_start</c> event for details on the FuncOrGroup element). With this event comes the
final result of the function in question. It is possible to determine on the top level
of <c>Result</c> if the function was successful, skipped (by the user), or if it failed.
It is of course possible to dig deeper and also perform pattern matching on the various
reasons for skipped or failed. Note that <c>{'EXIT',Reason}</c> tuples have been translated into
<c>{error,Reason}</c>. Note also that if a <c>{failed,{Suite,end_per_testcase,FailInfo}</c>
result is received, it actually means the test case was successful, but that
<c>end_per_testcase</c> for the case failed.
</p></item>
<item>
<marker id="tc_auto_skip"></marker>
<c>#event{name = tc_auto_skip, data = {Suite,Func,Reason}}</c>
<p><c>Suite = atom()</c>, the name of the suite.</p>
<p><c>Func = atom()</c>, the name of the test case or configuration function.</p>
<p><c>Reason = {failed,FailReason} |
{require_failed_in_suite0,RequireInfo}</c>,
reason for auto skipping <c>Func</c>.</p>
<p><c>FailReason = {Suite,ConfigFunc,FailInfo}} |
{Suite,FailedCaseInSequence}</c>, reason for failure.</p>
<p><c>RequireInfo = {not_available,atom() | tuple()}</c>, why require has failed.</p>
<p><c>ConfigFunc = init_per_suite | init_per_group</c></p>
<p><c>FailInfo = {timetrap_timeout,integer()} |
{RunTimeError,StackTrace} |
bad_return | UserTerm</c>,
detailed information about an error.</p>
<p><c>FailedCaseInSequence = atom()</c>, name of a case that has failed in a sequence.</p>
<p><c>RunTimeError = term()</c>, a run-time error, e.g. badmatch, undef, etc.</p>
<p><c>StackTrace = list()</c>, list of function calls preceeding a run-time error.</p>
<p><c>UserTerm = term()</c>, arbitrary data specified by user, or <c>exit/1</c> info.</p>
<p>This event gets sent for every test case or configuration function that Common Test
has skipped automatically because of either a failed <c>init_per_suite</c> or
<c>init_per_group</c>, a failed <c>require</c> in <c>suite/0</c>, or a failed test case
in a sequence. Note that this event is never received as a result of a test case getting
skipped because of <c>init_per_testcase</c> failing, since that information is carried with
the <c>tc_done</c> event.
</p></item>
<item>
<marker id="tc_user_skip"></marker>
<c>#event{name = tc_user_skip, data = {Suite,TestCase,Comment}}</c>
<p><c>Suite = atom()</c>, name of the suite.</p>
<p><c>TestCase = atom()</c>, name of the test case.</p>
<p><c>Comment = string()</c>, reason for skipping the test case.</p>
<p>This event specifies that a test case has been skipped by the user.
It is only ever received if the skip was declared in a test specification.
Otherwise, user skip information is received as a <c>{skipped,SkipReason}</c>
result in the <c>tc_done</c> event for the test case.
</p></item>
<item><c>#event{name = test_stats, data = {Ok,Failed,Skipped}}</c>
<p><c>Ok = integer()</c>, the current number of successful test cases.</p>
<p><c>Failed = integer()</c>, the current number of failed test cases.</p>
<p><c>Skipped = {UserSkipped,AutoSkipped}</c></p>
<p><c>UserSkipped = integer()</c>, the current number of user skipped test cases.</p>
<p><c>AutoSkipped = integer()</c>, the current number of auto skipped test cases.</p>
<p>This is a statistics event with the current count of successful, skipped
and failed test cases so far. This event gets sent after the end of each test case,
immediately following the <c>tc_done</c> event.
</p></item>
</list>
<p><em>Internal events:</em></p>
<list>
<item><c>#event{name = start_make, data = Dir}</c>
<p><c>Dir = string()</c>, running make in this directory.</p>
<p>An internal event saying that Common Test will start compiling
modules in directory <c>Dir</c>.
</p></item>
<item><c>#event{name = finished_make, data = Dir}</c>
<p><c>Dir = string()</c>, finished running make in this directory.</p>
<p>An internal event saying that Common Test is finished compiling
modules in directory <c>Dir</c>.
</p></item>
<item><c>#event{name = start_write_file, data = FullNameFile}</c>
<p><c>FullNameFile = string(), full name of the file.</c></p>
<p>An internal event used by the Common Test Master process to
synchronize particular file operations.
</p></item>
<item><c>#event{name = finished_write_file, data = FullNameFile}</c>
<p><c>FullNameFile = string(), full name of the file.</c></p>
<p>An internal event used by the Common Test Master process to
synchronize particular file operations.
</p></item>
</list>
<p>The events are also documented in <c>ct_event.erl</c>. This module
may serve as an example of what an event handler for the CT event
manager can look like.</p>
<note><p>To ensure that printouts to standard out (or printouts made with
<seealso marker="ct#log-2"><c>ct:log/2/3</c></seealso> or <seealso marker="ct:pal-2"><c>ct:pal/2/3</c></seealso>) get written to the test case log
file, and not to the Common Test framework log, you can syncronize
with the Common Test server by matching on the <c>tc_start</c> and <c>tc_done</c>
events. In the period between these events, all IO gets directed to the
test case log file. These events are sent synchronously to avoid potential
timing problems (e.g. that the test case log file gets closed just before
an IO message from an external process gets through). Knowing this, you
need to be careful that your <c>handle_event/2</c> callback function doesn't
stall the test execution, possibly causing unexpected behaviour as a result.</p></note>
</section>