1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
|
--
-- %CopyrightBegin%
--
-- Copyright Ericsson AB 2004-2009. All Rights Reserved.
--
-- The contents of this file are subject to the Erlang Public License,
-- Version 1.1, (the "License"); you may not use this file except in
-- compliance with the License. You should have received a copy of the
-- Erlang Public License along with this software. If not, it can be
-- retrieved online at http://www.erlang.org/.
--
-- Software distributed under the License is distributed on an "AS IS"
-- basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See
-- the License for the specific language governing rights and limitations
-- under the License.
--
-- %CopyrightEnd%
--
OTP-EVA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Counter32, Gauge32, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
otpModules, otpApplications
FROM OTP-REG
OwnerString
FROM OTP-TC
;
otpEvaModule MODULE-IDENTITY
LAST-UPDATED "0305090900Z"
ORGANIZATION "Ericsson"
CONTACT-INFO
"Contact: Erlang Support see license agreement for Erlang/OTP."
DESCRIPTION
"This MIB is part of the OTP MIB. It defines MIB objects
for the eva application in OTP."
REVISION "0305090900Z"
DESCRIPTION
"Changed CONTACT-INFO as it was outdated, made it more generic
to avoid such changes in the future."
REVISION "9801270900Z"
DESCRIPTION
"Changed erroneous defintion of alarmCleared notification.
Changed erroneous name of this module to otpEvaModule."
REVISION "9712010900Z"
DESCRIPTION
"Converted to v2 SMI and placed in the OTP tree."
REVISION "9705020900Z"
DESCRIPTION
"The initial version of this MIB module. It is very much
inspired by the ANS-ALM-MIB and Axd301Eva-OMS mibs."
::= { otpModules 6 }
otpEvaMIB OBJECT IDENTIFIER ::= { otpApplications 4 }
otpEvaMIBConformance
OBJECT IDENTIFIER ::= { otpEvaMIB 1 }
otpEvaMIBObjects
OBJECT IDENTIFIER ::= { otpEvaMIB 2 }
otpEvaMIBEvents OBJECT IDENTIFIER ::= { otpEvaMIB 3 }
otpEvaMIBEventsV2
OBJECT IDENTIFIER ::= { otpEvaMIBEvents 0 }
-- Datatypes
AlarmSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The AlarmSeverity defines six severity levels,
which provide an indication of how it is perceived that the
capability of the managed object has been affected. Those
severity levels which represent service affecting conditions
ordered from most severe to least severe are critical,
major, minor and warning. The levels used are as defined
in X.733, ITU Alarm Reporting Function:
o The Indeterminate severity level indicates that the
severity level cannot be determined.
o The Critical severity level indicates that a service
affecting condition has occurred and an immediate
corrective action is required. Such a severity can be
reported, for example, when a managed object becomes
totally out of service and its capability must be restored.
o The Major severity level indicates that a service
affecting condition has developed and an urgent corrective
action is required. Such a severity can be reported, for
example, when there is a severe degradation in the
capability of the managed object and its full capability
must be restored.
o The Minor severity level indicates the existence of a
non-service affecting fault condition and that corrective
action should be taken in order to prevent a more serious
(for example, service affecting) fault. Such a severity
can be reported, for example, when the detected alarm
condition is not currently degrading the capacity of the
managed object.
o The Warning severity level indicates the detection of a
potential or impending service affecting fault, before any
significant effects have been felt. Action should be taken
to further diagnose (if necessary) and correct the problem
in order to prevent it from becoming a more serious service
affecting fault.
When an alarm is cleared, an alarmCleared event is generated.
This event clears the alarm with the currentAlarmFaultId
contained in the event. It is not required that the clearing
of previously reported alarms are reported. Therefore, a managing
system cannot assume that the absence of an alarmedCleared event
for a fault means that the condition that caused the generation
of previous alarms is still present. Managed object definers
shall state if, and under which conditions, the alarmedCleared
event is used.
The clear value of AlarmSeverity is an action which is used when
a management station wants to clear an active alarm. This is not
possible on all systems, and thus an agent does not have support
write access for this value."
REFERENCE
"X.733, ITU Alarm Reporting Function"
SYNTAX INTEGER {
indeterminate (0),
critical (1),
major (2),
minor (3),
warning (4),
clear (5) -- Written, not read
}
AlarmClass ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The AlarmClass type categorizes the alarm, and is
defined when the alarm is registered. It is as defined in
X.733, ITU Alarm Reporting Function:
o communications. An alarm of this class is principally
associated with the procedures or processes required
to convey information from one point to another.
o qos. An alarm of this class is principally associated
with a degradation in the quality of service.
o processing. An alarm of this class is principally
associated with a software or processing fault.
o equipment. An alarm of this class is principally
associated with an equipment fault.
o environmental. An alarm of this class is principally
associated with a condition relating to an enclosure in
with equipment resides."
REFERENCE
"X.733, ITU Alarm Reporting Function"
SYNTAX INTEGER {
unknown (0),
communications (1),
qos (2),
processing (3),
equipment (4),
environmental (5)
}
-- Managed Objects
event OBJECT IDENTIFIER ::= { otpEvaMIBObjects 1 }
alarm OBJECT IDENTIFIER ::= { otpEvaMIBObjects 2 }
currentAlarm OBJECT IDENTIFIER ::= { otpEvaMIBObjects 3 }
-- The Event group
--
-- The Event group controls the generation of notifications of
-- events from the system.
eventTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of events defined by the system. This table is used
to control the sending of traps and to whom the traps are
sent."
::= { event 1 }
eventEntry OBJECT-TYPE
SYNTAX EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that describe an event to be
generated when certain conditions are met."
INDEX { eventIndex }
::= { eventTable 1 }
EventEntry ::= SEQUENCE {
eventIndex Integer32 (1..2147483647),
eventTrapName DisplayString,
eventTreatment INTEGER,
eventCommunity OCTET STRING (SIZE (0..127)),
eventSentTraps Counter32,
eventOwner OwnerString
}
eventIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
event table. Each such entry defines one event that
is to be generated when the appropriate conditions
occur. The value for each eventIndex must remain
constant, at least from one re-initialization of the
entity's network management system to the next
re-initialization."
::= { eventEntry 1 }
eventTrapName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The identifier of the corresponding trap.
NOTE: this should be an OID in SNMPv2, but must be
a string in v1."
::= { eventEntry 2 }
eventTreatment OBJECT-TYPE
SYNTAX INTEGER {
none(1),
log(2),
snmpTrap(3),
logAndTrap(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines how the system shall treat this event. In the
case of snmpTrap, an SNMP trap is sent to one or more
management stations. In the case of log, the event is
guaranteed to be logged in a log according to some log
strategy. Each such log strategy may define a MIB module
for control and examination of logs."
::= { eventEntry 3 }
eventCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If an SNMP trap is to be sent, it will be sent to
the SNMP community specified by this octet string."
::= { eventEntry 4 }
eventSentTraps OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this event has been sent as a trap."
::= { eventEntry 5 }
eventOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager entity that 'owns' this event entry, and is
therefore responsible for its contents."
::= { eventEntry 6 }
eventTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object may be included in a trap definition for an event.
It specifies the time the event was generated."
::= { event 2 }
-- The Alarm group
--
-- The Alarm group extends the Event group with objects for alarms.
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains additional information for alarm events."
::= { alarm 1 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters for alarms."
INDEX { eventIndex }
::= { alarmTable 1 }
AlarmEntry ::= SEQUENCE {
alarmClass AlarmClass,
alarmSeverity AlarmSeverity
}
alarmClass OBJECT-TYPE
SYNTAX AlarmClass
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The class of this alarm."
::= { alarmEntry 1 }
alarmSeverity OBJECT-TYPE
SYNTAX AlarmSeverity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The perceived severity that shall apply to the
associated alarms."
::= { alarmEntry 2 }
-- The CurrentAlarm group
--
-- The CurrentAlarm group is a collection of objects for monitoring of
-- active alarms in the system.
numberOfCurrentAlarms OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of currently active alarms in the system."
::= { currentAlarm 1 }
currentAlarmLastTimeChanged OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time an entry in the currentAlarmTable was changed.
It may be used by a management station as a value to
poll. If the value is changed, the management station
knows that the currentAlarmTable has been updated."
::= { currentAlarm 2 }
currentAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of currently active alarms in the system."
::= { currentAlarm 3 }
currentAlarmEntry OBJECT-TYPE
SYNTAX CurrentAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that describe a currently active
alarm."
INDEX { currentAlarmFaultId }
::= { currentAlarmTable 1 }
CurrentAlarmEntry ::= SEQUENCE {
currentAlarmFaultId Integer32 (1..2147483647),
currentAlarmEventIndex Integer32 (1..2147483647),
currentAlarmObject OBJECT IDENTIFIER,
currentAlarmCause OBJECT IDENTIFIER,
currentAlarmSeverity AlarmSeverity,
currentAlarmTime DateAndTime,
currentAlarmInformation DisplayString,
currentAlarmExtra1 OBJECT IDENTIFIER,
currentAlarmExtra2 OBJECT IDENTIFIER
}
currentAlarmFaultId OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An id that uniquely identifies a fault. Each fault is
represented as one an entry in the currentAlarmTable."
::= { currentAlarmEntry 1 }
currentAlarmEventIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer into the eventTable. Points to the event
corresponding to this alarm."
::= { currentAlarmEntry 2 }
currentAlarmObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming object."
::= { currentAlarmEntry 3 }
currentAlarmCause OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The probable cause of the alarm."
::= { currentAlarmEntry 4 }
currentAlarmSeverity OBJECT-TYPE
SYNTAX AlarmSeverity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The perceived severity of the fault. A manager can set
this value to clear only. When set to clear, the alarm
is removed from this table, and a 'clearAlarm' event is
generated."
::= { currentAlarmEntry 5 }
currentAlarmTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time the fault was detected."
::= { currentAlarmEntry 6 }
currentAlarmInformation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Additional information pin-pointing the problem."
::= { currentAlarmEntry 7 }
currentAlarmExtra1 OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An extra parameter used for some alarms at their own
discretion. Can be used for example to identify
additional objects in the alarm, or instead of
currentAlarmInformation to pin-point the problem, if the
additional information is defined in some MIB."
::= { currentAlarmEntry 8 }
currentAlarmExtra2 OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An extra parameter used for some alarms at their own
discretion. Can be used for example to identify
additional objects in the alarm, or instead of
currentAlarmInformation to pin-point the problem, if the
additional information is defined in some MIB."
::= { currentAlarmEntry 9 }
-- Events
alarmCleared NOTIFICATION-TYPE
OBJECTS {
currentAlarmEventIndex,
eventTime
}
STATUS current
DESCRIPTION
"This event is sent when an alarm has been cleared,
either by the application or by an operator. Note that the
currentAlarmFaultId is implicitly sent as the instance identifier
for currentAlarmEventIndex."
::= { otpEvaMIBEventsV2 1 }
-- conformance information
otpEvaMIBCompliances
OBJECT IDENTIFIER ::= { otpEvaMIBConformance 1 }
otpEvaMIBGroups
OBJECT IDENTIFIER ::= { otpEvaMIBConformance 2 }
-- compliance statements
otpEvaBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities which
implement the OTP-EVA-MIB."
MODULE -- this module
MANDATORY-GROUPS { eventGroup,
alarmGroup,
currentAlarmGroup,
evaEventsGroup }
::= { otpEvaMIBCompliances 1 }
-- units of conformance
eventGroup OBJECT-GROUP
OBJECTS { eventTrapName,
eventTreatment,
eventCommunity,
eventSentTraps,
eventOwner,
eventTime }
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation
and control of the events defined in the OTP system."
::= { otpEvaMIBGroups 1 }
alarmGroup OBJECT-GROUP
OBJECTS { alarmClass,
alarmSeverity }
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation
and control of the alarms defined the OTP system."
::= { otpEvaMIBGroups 2 }
currentAlarmGroup OBJECT-GROUP
OBJECTS { numberOfCurrentAlarms,
currentAlarmLastTimeChanged,
currentAlarmEventIndex,
currentAlarmObject,
currentAlarmCause,
currentAlarmSeverity,
currentAlarmTime,
currentAlarmInformation,
currentAlarmExtra1,
currentAlarmExtra2 }
STATUS current
DESCRIPTION
"A collection of objects providing basic instrumentation
of the activa alarm list in the OTP system."
::= { otpEvaMIBGroups 3 }
evaEventsGroup NOTIFICATION-GROUP
NOTIFICATIONS { alarmCleared }
STATUS current
DESCRIPTION
"The notification which is generated from EVA."
::= { otpEvaMIBGroups 4 }
END
|