1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
|
<?xml version="1.0" encoding="utf-8" ?>
<!DOCTYPE erlref SYSTEM "erlref.dtd">
<erlref>
<header>
<copyright>
<year>1996</year><year>2014</year>
<holder>Ericsson AB. All Rights Reserved.</holder>
</copyright>
<legalnotice>
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
</legalnotice>
<title>gen_event</title>
<prepared></prepared>
<docno></docno>
<date></date>
<rev></rev>
</header>
<module>gen_event</module>
<modulesummary>Generic Event Handling Behaviour</modulesummary>
<description>
<p>A behaviour module for implementing event handling functionality.
The OTP event handling model consists of a generic event manager
process with an arbitrary number of event handlers which are added and
deleted dynamically.</p>
<p>An event manager implemented using this module will have a standard
set of interface functions and include functionality for tracing and
error reporting. It will also fit into an OTP supervision tree.
Refer to <em>OTP Design Principles</em> for more information.</p>
<p>Each event handler is implemented as a callback module exporting
a pre-defined set of functions. The relationship between the behaviour
functions and the callback functions can be illustrated as follows:</p>
<pre>
gen_event module Callback module
---------------- ---------------
gen_event:start
gen_event:start_link -----> -
gen_event:add_handler
gen_event:add_sup_handler -----> Module:init/1
gen_event:notify
gen_event:sync_notify -----> Module:handle_event/2
gen_event:call -----> Module:handle_call/2
- -----> Module:handle_info/2
gen_event:delete_handler -----> Module:terminate/2
gen_event:swap_handler
gen_event:swap_sup_handler -----> Module1:terminate/2
Module2:init/1
gen_event:which_handlers -----> -
gen_event:stop -----> Module:terminate/2
- -----> Module:code_change/3</pre>
<p>Since each event handler is one callback module, an event manager
will have several callback modules which are added and deleted
dynamically. Therefore <c>gen_event</c> is more tolerant of callback
module errors than the other behaviours. If a callback function for
an installed event handler fails with <c>Reason</c>, or returns a
bad value <c>Term</c>, the event manager will not fail. It will delete
the event handler by calling the callback function
<c>Module:terminate/2</c> (see below), giving as argument
<c>{error,{'EXIT',Reason}}</c> or <c>{error,Term}</c>, respectively.
No other event handler will be affected.</p>
<p>A gen_event process handles system messages as documented in
<seealso marker="sys">sys(3)</seealso>. The <c>sys</c> module
can be used for debugging an event manager.</p>
<p>Note that an event manager <em>does</em> trap exit signals
automatically.</p>
<p>The gen_event process can go into hibernation
(see <seealso marker="erts:erlang#erlang:hibernate/3">erlang(3)</seealso>) if a callback
function in a handler module specifies <c>'hibernate'</c> in its return value.
This might be useful if the server is expected to be idle for a long
time. However this feature should be used with care as hibernation
implies at least two garbage collections (when hibernating and
shortly after waking up) and is not something you'd want to do
between each event handled by a busy event manager.</p>
<p>It's also worth noting that when multiple event handlers are
invoked, it's sufficient that one single event handler returns a
<c>'hibernate'</c> request for the whole event manager to go into
hibernation.</p>
<p>Unless otherwise stated, all functions in this module fail if
the specified event manager does not exist or if bad arguments are
given.</p>
</description>
<datatypes>
<datatype>
<name name="handler"/>
</datatype>
<datatype>
<name name="handler_args"/>
</datatype>
<datatype>
<name name="add_handler_ret"/>
</datatype>
<datatype>
<name name="del_handler_ret"/>
</datatype>
</datatypes>
<funcs>
<func>
<name>start_link() -> Result</name>
<name>start_link(EventMgrName) -> Result</name>
<fsummary>Create a generic event manager process in a supervision tree.</fsummary>
<type>
<v>EventMgrName = {local,Name} | {global,GlobalName}
| {via,Module,ViaName}</v>
<v> Name = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Result = {ok,Pid} | {error,{already_started,Pid}}</v>
<v> Pid = pid()</v>
</type>
<desc>
<p>Creates an event manager process as part of a supervision
tree. The function should be called, directly or indirectly,
by the supervisor. It will, among other things, ensure that
the event manager is linked to the supervisor.</p>
<p>If <c>EventMgrName={local,Name}</c>, the event manager is
registered locally as <c>Name</c> using <c>register/2</c>.
If <c>EventMgrName={global,GlobalName}</c>, the event manager is
registered globally as <c>GlobalName</c> using
<c>global:register_name/2</c>. If no name is provided,
the event manager is not registered.
If <c>EventMgrName={via,Module,ViaName}</c>, the event manager will
register with the registry represented by <c>Module</c>.
The <c>Module</c> callback should export the functions
<c>register_name/2</c>, <c>unregister_name/1</c>,
<c>whereis_name/1</c> and <c>send/2</c>, which should behave like the
corresponding functions in <c>global</c>. Thus,
<c>{via,global,GlobalName}</c> is a valid reference.</p>
<p>If the event manager is successfully created the function
returns <c>{ok,Pid}</c>, where <c>Pid</c> is the pid of
the event manager. If there already exists a process with
the specified <c>EventMgrName</c> the function returns
<c>{error,{already_started,Pid}}</c>, where <c>Pid</c> is
the pid of that process.</p>
</desc>
</func>
<func>
<name>start() -> Result</name>
<name>start(EventMgrName) -> Result</name>
<fsummary>Create a stand-alone event manager process.</fsummary>
<type>
<v>EventMgrName = {local,Name} | {global,GlobalName}
| {via,Module,ViaName}</v>
<v> Name = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Result = {ok,Pid} | {error,{already_started,Pid}}</v>
<v> Pid = pid()</v>
</type>
<desc>
<p>Creates a stand-alone event manager process, i.e. an event
manager which is not part of a supervision tree and thus has
no supervisor.</p>
<p>See <c>start_link/0,1</c> for a description of arguments and
return values.</p>
</desc>
</func>
<func>
<name>add_handler(EventMgrRef, Handler, Args) -> Result</name>
<fsummary>Add an event handler to a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args = term()</v>
<v>Result = ok | {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Adds a new event handler to the event manager <c>EventMgrRef</c>.
The event manager will call <c>Module:init/1</c> to initiate
the event handler and its internal state.</p>
<p><c>EventMgrRef</c> can be:</p>
<list type="bulleted">
<item>the pid,</item>
<item><c>Name</c>, if the event manager is locally registered,</item>
<item><c>{Name,Node}</c>, if the event manager is locally
registered at another node, or</item>
<item><c>{global,GlobalName}</c>, if the event manager is globally
registered.</item>
<item><c>{via,Module,ViaName}</c>, if the event manager is registered
through an alternative process registry.</item>
</list>
<p><c>Handler</c> is the name of the callback module <c>Module</c> or
a tuple <c>{Module,Id}</c>, where <c>Id</c> is any term.
The <c>{Module,Id}</c> representation makes it possible to
identify a specific event handler when there are several event
handlers using the same callback module.</p>
<p><c>Args</c> is an arbitrary term which is passed as the argument
to <c>Module:init/1</c>.</p>
<p>If <c>Module:init/1</c> returns a correct value indicating
successful completion, the event manager adds the event
handler and this function returns
<c>ok</c>. If <c>Module:init/1</c> fails with <c>Reason</c> or
returns <c>{error,Reason}</c>, the event handler is
ignored and this function returns <c>{'EXIT',Reason}</c> or
<c>{error,Reason}</c>, respectively.</p>
</desc>
</func>
<func>
<name>add_sup_handler(EventMgrRef, Handler, Args) -> Result</name>
<fsummary>Add a supervised event handler to a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args = term()</v>
<v>Result = ok | {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Adds a new event handler in the same way as <c>add_handler/3</c>
but will also supervise the connection between the event handler
and the calling process.</p>
<list type="bulleted">
<item>If the calling process later terminates with <c>Reason</c>,
the event manager will delete the event handler by calling
<c>Module:terminate/2</c> with <c>{stop,Reason}</c> as argument.</item>
<item>
<p>If the event handler later is deleted, the event manager
sends a message<c>{gen_event_EXIT,Handler,Reason}</c> to
the calling process. <c>Reason</c> is one of the following:</p>
<list type="bulleted">
<item><c>normal</c>, if the event handler has been removed due to a
call to <c>delete_handler/3</c>, or <c>remove_handler</c>
has been returned by a callback function (see below).</item>
<item><c>shutdown</c>, if the event handler has been removed
because the event manager is terminating.</item>
<item><c>{swapped,NewHandler,Pid}</c>, if the process <c>Pid</c>
has replaced the event handler with another event handler
<c>NewHandler</c> using a call to <c>swap_handler/3</c> or
<c>swap_sup_handler/3</c>.</item>
<item>a term, if the event handler is removed due to an error.
Which term depends on the error.</item>
</list>
</item>
</list>
<p>See <c>add_handler/3</c> for a description of the arguments
and return values.</p>
</desc>
</func>
<func>
<name>notify(EventMgrRef, Event) -> ok</name>
<name>sync_notify(EventMgrRef, Event) -> ok</name>
<fsummary>Notify an event manager about an event.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Event = term()</v>
</type>
<desc>
<p>Sends an event notification to the event manager
<c>EventMgrRef</c>. The event manager will call
<c>Module:handle_event/2</c> for each installed event handler to
handle the event.</p>
<p><c>notify</c> is asynchronous and will return immediately after
the event notification has been sent. <c>sync_notify</c> is
synchronous in the sense that it will return <c>ok</c> after
the event has been handled by all event handlers.</p>
<p>See <c>add_handler/3</c> for a description of <c>EventMgrRef</c>.</p>
<p><c>Event</c> is an arbitrary term which is passed as one of
the arguments to <c>Module:handle_event/2</c>.</p>
<p><c>notify</c> will not fail even if the specified event manager
does not exist, unless it is specified as <c>Name</c>.</p>
</desc>
</func>
<func>
<name>call(EventMgrRef, Handler, Request) -> Result</name>
<name>call(EventMgrRef, Handler, Request, Timeout) -> Result</name>
<fsummary>Make a synchronous call to a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Request = term()</v>
<v>Timeout = int()>0 | infinity</v>
<v>Result = Reply | {error,Error}</v>
<v> Reply = term()</v>
<v> Error = bad_module | {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Makes a synchronous call to the event handler <c>Handler</c>
installed in the event manager <c>EventMgrRef</c> by sending a
request and waiting until a reply arrives or a timeout occurs.
The event manager will call <c>Module:handle_call/2</c> to handle
the request.</p>
<p>See <c>add_handler/3</c> for a description of <c>EventMgrRef</c>
and <c>Handler</c>.</p>
<p><c>Request</c> is an arbitrary term which is passed as one of
the arguments to <c>Module:handle_call/2</c>.</p>
<p><c>Timeout</c> is an integer greater than zero which specifies
how many milliseconds to wait for a reply, or the atom
<c>infinity</c> to wait indefinitely. Default value is 5000.
If no reply is received within the specified time, the function
call fails.</p>
<p>The return value <c>Reply</c> is defined in the return value of
<c>Module:handle_call/2</c>. If the specified event handler is not
installed, the function returns <c>{error,bad_module}</c>. If
the callback function fails with <c>Reason</c> or returns an
unexpected value <c>Term</c>, this function returns
<c>{error,{'EXIT',Reason}}</c> or <c>{error,Term}</c>,
respectively.</p>
</desc>
</func>
<func>
<name>delete_handler(EventMgrRef, Handler, Args) -> Result</name>
<fsummary>Delete an event handler from a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args = term()</v>
<v>Result = term() | {error,module_not_found} | {'EXIT',Reason}</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Deletes an event handler from the event manager
<c>EventMgrRef</c>. The event manager will call
<c>Module:terminate/2</c> to terminate the event handler.</p>
<p>See <c>add_handler/3</c> for a description of <c>EventMgrRef</c>
and <c>Handler</c>.</p>
<p><c>Args</c> is an arbitrary term which is passed as one of
the arguments to <c>Module:terminate/2</c>.</p>
<p>The return value is the return value of <c>Module:terminate/2</c>.
If the specified event handler is not installed, the function
returns <c>{error,module_not_found}</c>. If the callback function
fails with <c>Reason</c>, the function returns
<c>{'EXIT',Reason}</c>.</p>
</desc>
</func>
<func>
<name>swap_handler(EventMgrRef, {Handler1,Args1}, {Handler2,Args2}) -> Result</name>
<fsummary>Replace an event handler in a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler1 = Handler2 = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args1 = Args2 = term()</v>
<v>Result = ok | {error,Error}</v>
<v> Error = {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Replaces an old event handler with a new event handler in
the event manager <c>EventMgrRef</c>.</p>
<p>See <c>add_handler/3</c> for a description of the arguments.</p>
<p>First the old event handler <c>Handler1</c> is deleted.
The event manager calls <c>Module1:terminate(Args1, ...)</c>,
where <c>Module1</c> is the callback module of <c>Handler1</c>,
and collects the return value.</p>
<p>Then the new event handler <c>Handler2</c> is added and initiated
by calling <c>Module2:init({Args2,Term})</c>, where <c>Module2</c>
is the callback module of <c>Handler2</c> and <c>Term</c>
the return value of <c>Module1:terminate/2</c>. This makes it
possible to transfer information from <c>Handler1</c> to
<c>Handler2</c>.</p>
<p>The new handler will be added even if the the specified old event
handler is not installed in which case <c>Term=error</c>, or if
<c>Module1:terminate/2</c> fails with <c>Reason</c> in which case
<c>Term={'EXIT',Reason}</c>.
The old handler will be deleted even if <c>Module2:init/1</c>
fails.</p>
<p>If there was a supervised connection between <c>Handler1</c> and
a process <c>Pid</c>, there will be a supervised connection
between <c>Handler2</c> and <c>Pid</c> instead.</p>
<p>If <c>Module2:init/1</c> returns a correct value, this function
returns <c>ok</c>. If <c>Module2:init/1</c> fails with
<c>Reason</c> or returns an unexpected value <c>Term</c>, this
this function returns <c>{error,{'EXIT',Reason}}</c> or
<c>{error,Term}</c>, respectively.</p>
</desc>
</func>
<func>
<name>swap_sup_handler(EventMgrRef, {Handler1,Args1}, {Handler2,Args2}) -> Result</name>
<fsummary>Replace an event handler in a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler1 = Handler 2 = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args1 = Args2 = term()</v>
<v>Result = ok | {error,Error}</v>
<v> Error = {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Replaces an event handler in the event manager <c>EventMgrRef</c>
in the same way as <c>swap_handler/3</c> but will also supervise
the connection between <c>Handler2</c> and the calling process.</p>
<p>See <c>swap_handler/3</c> for a description of the arguments
and return values.</p>
</desc>
</func>
<func>
<name>which_handlers(EventMgrRef) -> [Handler]</name>
<fsummary>Return all event handlers installed in a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>Returns a list of all event handlers installed in the event
manager <c>EventMgrRef</c>.</p>
<p>See <c>add_handler/3</c> for a description of <c>EventMgrRef</c>
and <c>Handler</c>.</p>
</desc>
</func>
<func>
<name>stop(EventMgrRef) -> ok</name>
<name>stop(EventMgrRef, Reason, Timeout) -> ok</name>
<fsummary>Terminate a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v>Name = Node = atom()</v>
<v>GlobalName = ViaName = term()</v>
<v>Reason = term()</v>
<v>Timeout = int()>0 | infinity</v>
</type>
<desc>
<p>Orders the event manager <c>EventMgrRef</c> to exit with
the given <c>Reason</c> and waits for it to
terminate. Before terminating, the gen_event will call
<seealso marker="#Module:terminate/2">Module:terminate(stop,...)</seealso>
for each installed event handler.</p>
<p>The function returns <c>ok</c> if the event manager terminates
with the expected reason. Any other reason than <c>normal</c>,
<c>shutdown</c>, or <c>{shutdown,Term}</c> will cause an
error report to be issued using
<seealso marker="kernel:error_logger#format/2">error_logger:format/2</seealso>.
The default <c>Reason</c> is <c>normal</c>.</p>
<p><c>Timeout</c> is an integer greater than zero which
specifies how many milliseconds to wait for the event manager to
terminate, or the atom <c>infinity</c> to wait
indefinitely. The default value is <c>infinity</c>. If the
event manager has not terminated within the specified time, a
<c>timeout</c> exception is raised.</p>
<p>If the process does not exist, a <c>noproc</c> exception
is raised.</p>
<p>See <c>add_handler/3</c> for a description of <c>EventMgrRef</c>.</p>
</desc>
</func>
</funcs>
<section>
<title>CALLBACK FUNCTIONS</title>
<p>The following functions should be exported from a <c>gen_event</c>
callback module.</p>
</section>
<funcs>
<func>
<name>Module:init(InitArgs) -> {ok,State} | {ok,State,hibernate} | {error,Reason}</name>
<fsummary>Initialize an event handler.</fsummary>
<type>
<v>InitArgs = Args | {Args,Term}</v>
<v> Args = Term = term()</v>
<v>State = term()</v>
<v>Reason = term()</v>
</type>
<desc>
<p>Whenever a new event handler is added to an event manager,
this function is called to initialize the event handler.</p>
<p>If the event handler is added due to a call to
<c>gen_event:add_handler/3</c> or
<c>gen_event:add_sup_handler/3</c>, <c>InitArgs</c> is
the <c>Args</c> argument of these functions.</p>
<p>If the event handler is replacing another event handler due to
a call to <c>gen_event:swap_handler/3</c> or
<c>gen_event:swap_sup_handler/3</c>, or due to a <c>swap</c>
return tuple from one of the other callback functions,
<c>InitArgs</c> is a tuple <c>{Args,Term}</c> where <c>Args</c> is
the argument provided in the function call/return tuple and
<c>Term</c> is the result of terminating the old event handler,
see <c>gen_event:swap_handler/3</c>.</p>
<p>If successful, the function should return <c>{ok,State}</c>
or <c>{ok,State,hibernate}</c> where <c>State</c> is the
initial internal state of the event handler.</p>
<p>If <c>{ok,State,hibernate}</c> is returned, the event
manager will go into hibernation (by calling <seealso
marker="proc_lib#hibernate/3">proc_lib:hibernate/3</seealso>),
waiting for the next event to occur.</p>
</desc>
</func>
<func>
<name>Module:handle_event(Event, State) -> Result</name>
<fsummary>Handle an event.</fsummary>
<type>
<v>Event = term()</v>
<v>State = term()</v>
<v>Result = {ok,NewState} | {ok,NewState,hibernate} </v>
<v> | {swap_handler,Args1,NewState,Handler2,Args2} | remove_handler</v>
<v> NewState = term()</v>
<v> Args1 = Args2 = term()</v>
<v> Handler2 = Module2 | {Module2,Id}</v>
<v> Module2 = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>Whenever an event manager receives an event sent using
<c>gen_event:notify/2</c> or <c>gen_event:sync_notify/2</c>, this
function is called for each installed event handler to handle
the event.</p>
<p><c>Event</c> is the <c>Event</c> argument of
<c>notify</c>/<c>sync_notify</c>.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p>If the function returns <c>{ok,NewState}</c> or <c>{ok,NewState,hibernate}</c>
the event handler
will remain in the event manager with the possible updated
internal state <c>NewState</c>.</p>
<p>If <c>{ok,NewState,hibernate}</c> is returned, the event
manager will also go into hibernation (by calling <seealso
marker="proc_lib#hibernate/3">proc_lib:hibernate/3</seealso>),
waiting for the next event to occur. It is sufficient that one of the event
handlers return <c>{ok,NewState,hibernate}</c> for the whole event manager
process to hibernate.</p>
<p>If the function returns
<c>{swap_handler,Args1,NewState,Handler2,Args2}</c> the event
handler will be replaced by <c>Handler2</c> by first calling
<c>Module:terminate(Args1,NewState)</c> and then
<c>Module2:init({Args2,Term})</c> where <c>Term</c> is the return
value of <c>Module:terminate/2</c>.
See <c>gen_event:swap_handler/3</c> for more information.</p>
<p>If the function returns <c>remove_handler</c> the event handler
will be deleted by calling
<c>Module:terminate(remove_handler,State)</c>.</p>
</desc>
</func>
<func>
<name>Module:handle_call(Request, State) -> Result</name>
<fsummary>Handle a synchronous request.</fsummary>
<type>
<v>Request = term()</v>
<v>State = term()</v>
<v>Result = {ok,Reply,NewState} | {ok,Reply,NewState,hibernate}</v>
<v> | {swap_handler,Reply,Args1,NewState,Handler2,Args2}</v>
<v> | {remove_handler, Reply}</v>
<v> Reply = term()</v>
<v> NewState = term()</v>
<v> Args1 = Args2 = term()</v>
<v> Handler2 = Module2 | {Module2,Id}</v>
<v> Module2 = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>Whenever an event manager receives a request sent using
<c>gen_event:call/3,4</c>, this function is called for
the specified event handler to handle the request.</p>
<p><c>Request</c> is the <c>Request</c> argument of <c>call</c>.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p>The return values are the same as for <c>handle_event/2</c>
except they also contain a term <c>Reply</c> which is the reply
given back to the client as the return value of <c>call</c>.</p>
</desc>
</func>
<func>
<name>Module:handle_info(Info, State) -> Result</name>
<fsummary>Handle an incoming message.</fsummary>
<type>
<v>Info = term()</v>
<v>State = term()</v>
<v>Result = {ok,NewState} | {ok,NewState,hibernate}</v>
<v> | {swap_handler,Args1,NewState,Handler2,Args2} | remove_handler</v>
<v> NewState = term()</v>
<v> Args1 = Args2 = term()</v>
<v> Handler2 = Module2 | {Module2,Id}</v>
<v> Module2 = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>This function is called for each installed event handler when
an event manager receives any other message than an event or
a synchronous request (or a system message).</p>
<p><c>Info</c> is the received message.</p>
<p>See <c>Module:handle_event/2</c> for a description of State
and possible return values.</p>
</desc>
</func>
<func>
<name>Module:terminate(Arg, State) -> term()</name>
<fsummary>Clean up before deletion.</fsummary>
<type>
<v>Arg = Args | {stop,Reason} | stop | remove_handler</v>
<v> | {error,{'EXIT',Reason}} | {error,Term}</v>
<v> Args = Reason = Term = term()</v>
</type>
<desc>
<p>Whenever an event handler is deleted from an event manager,
this function is called. It should be the opposite of
<c>Module:init/1</c> and do any necessary cleaning up.</p>
<p>If the event handler is deleted due to a call to
<c>gen_event:delete_handler</c>, <c>gen_event:swap_handler/3</c>
or <c>gen_event:swap_sup_handler/3</c>, <c>Arg</c> is
the <c>Args</c> argument of this function call.</p>
<p><c>Arg={stop,Reason}</c> if the event handler has a supervised
connection to a process which has terminated with reason
<c>Reason</c>.</p>
<p><c>Arg=stop</c> if the event handler is deleted because
the event manager is terminating.</p>
<p>The event manager will terminate if it is part of a supervision
tree and it is ordered by its supervisor to terminate.
Even if it is <em>not</em> part of a supervision tree, it will
terminate if it receives an <c>'EXIT'</c> message from
its parent.</p>
<p><c>Arg=remove_handler</c> if the event handler is deleted because
another callback function has returned <c>remove_handler</c> or
<c>{remove_handler,Reply}</c>.</p>
<p><c>Arg={error,Term}</c> if the event handler is deleted because
a callback function returned an unexpected value <c>Term</c>,
or <c>Arg={error,{'EXIT',Reason}}</c> if a callback function
failed.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p>The function may return any term. If the event handler is
deleted due to a call to <c>gen_event:delete_handler</c>,
the return value of that function will be the return value of this
function. If the event handler is to be replaced with another event
handler due to a swap, the return value will be passed to
the <c>init</c> function of the new event handler. Otherwise
the return value is ignored.</p>
</desc>
</func>
<func>
<name>Module:code_change(OldVsn, State, Extra) -> {ok, NewState}</name>
<fsummary>Update the internal state during upgrade/downgrade.</fsummary>
<type>
<v>OldVsn = Vsn | {down, Vsn}</v>
<v> Vsn = term()</v>
<v>State = NewState = term()</v>
<v>Extra = term()</v>
</type>
<desc>
<p>This function is called for an installed event handler which
should update its internal state during a release
upgrade/downgrade, i.e. when the instruction
<c>{update,Module,Change,...}</c> where
<c>Change={advanced,Extra}</c> is given in the <c>.appup</c>
file. See <em>OTP Design Principles</em> for more
information.</p>
<p>In the case of an upgrade, <c>OldVsn</c> is <c>Vsn</c>, and
in the case of a downgrade, <c>OldVsn</c> is
<c>{down,Vsn}</c>. <c>Vsn</c> is defined by the <c>vsn</c>
attribute(s) of the old version of the callback module
<c>Module</c>. If no such attribute is defined, the version
is the checksum of the BEAM file.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p><c>Extra</c> is passed as-is from the <c>{advanced,Extra}</c>
part of the update instruction.</p>
<p>The function should return the updated internal state.</p>
</desc>
</func>
<func>
<name>Module:format_status(Opt, [PDict, State]) -> Status</name>
<fsummary>Optional function for providing a term describing the
current event handler state.</fsummary>
<type>
<v>Opt = normal | terminate</v>
<v>PDict = [{Key, Value}]</v>
<v>State = term()</v>
<v>Status = term()</v>
</type>
<desc>
<note>
<p>This callback is optional, so event handler modules need
not export it. If a handler does not export this function,
the gen_event module uses the handler state directly for
the purposes described below.</p>
</note>
<p>This function is called by a gen_event process when:</p>
<list type="bulleted">
<item>One
of <seealso marker="sys#get_status/1">sys:get_status/1,2</seealso>
is invoked to get the gen_event status. <c>Opt</c> is set
to the atom <c>normal</c> for this case.</item>
<item>The event handler terminates abnormally and gen_event
logs an error. <c>Opt</c> is set to the
atom <c>terminate</c> for this case.</item>
</list>
<p>This function is useful for customising the form and
appearance of the event handler state for these cases. An
event handler callback module wishing to customise
the <c>sys:get_status/1,2</c> return value as well as how
its state appears in termination error logs exports an
instance of <c>format_status/2</c> that returns a term
describing the current state of the event handler.</p>
<p><c>PDict</c> is the current value of the gen_event's
process dictionary.</p>
<p><c>State</c> is the internal state of the event
handler.</p>
<p>The function should return <c>Status</c>, a term that
customises the details of the current state of the event
handler. Any term is allowed for <c>Status</c>. The
gen_event module uses <c>Status</c> as follows:</p>
<list type="bulleted">
<item>When <c>sys:get_status/1,2</c> is called, gen_event
ensures that its return value contains <c>Status</c> in
place of the event handler's actual state term.</item>
<item>When an event handler terminates abnormally, gen_event
logs <c>Status</c> in place of the event handler's actual
state term.</item>
</list>
<p>One use for this function is to return compact alternative
state representations to avoid having large state terms
printed in logfiles.</p>
</desc>
</func>
</funcs>
<section>
<title>SEE ALSO</title>
<p><seealso marker="supervisor">supervisor(3)</seealso>,
<seealso marker="sys">sys(3)</seealso></p>
</section>
</erlref>
|