1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
|
<?xml version="1.0" encoding="utf-8" ?>
<!DOCTYPE erlref SYSTEM "erlref.dtd">
<erlref>
<header>
<copyright>
<year>1996</year><year>2016</year>
<holder>Ericsson AB. All Rights Reserved.</holder>
</copyright>
<legalnotice>
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
</legalnotice>
<title>gen_event</title>
<prepared></prepared>
<docno></docno>
<date></date>
<rev></rev>
</header>
<module>gen_event</module>
<modulesummary>Generic event handling behavior.</modulesummary>
<description>
<p>This behavior module provides event handling functionality. It
consists of a generic event manager process with any number of
event handlers that are added and deleted dynamically.</p>
<p>An event manager implemented using this module has a standard
set of interface functions and includes functionality for tracing and
error reporting. It also fits into an OTP supervision tree. For more
information, see
<seealso marker="doc/design_principles:events">OTP Design Principles</seealso>.
</p>
<p>Each event handler is implemented as a callback module exporting
a predefined set of functions. The relationship between the behavior
functions and the callback functions is as follows:</p>
<pre>
gen_event module Callback module
---------------- ---------------
gen_event:start
gen_event:start_link -----> -
gen_event:add_handler
gen_event:add_sup_handler -----> Module:init/1
gen_event:notify
gen_event:sync_notify -----> Module:handle_event/2
gen_event:call -----> Module:handle_call/2
- -----> Module:handle_info/2
gen_event:delete_handler -----> Module:terminate/2
gen_event:swap_handler
gen_event:swap_sup_handler -----> Module1:terminate/2
Module2:init/1
gen_event:which_handlers -----> -
gen_event:stop -----> Module:terminate/2
- -----> Module:code_change/3</pre>
<p>As each event handler is one callback module, an event manager
has many callback modules that are added and deleted
dynamically. <c>gen_event</c> is therefore more tolerant of callback
module errors than the other behaviors. If a callback function for
an installed event handler fails with <c>Reason</c>, or returns a
bad value <c>Term</c>, the event manager does not fail. It deletes
the event handler by calling callback function
<seealso marker="#Module:terminate/2"><c>Module:terminate/2</c></seealso>,
giving as argument
<c>{error,{'EXIT',Reason}}</c> or <c>{error,Term}</c>, respectively.
No other event handler is affected.</p>
<p>A <c>gen_event</c> process handles system messages as described in
<seealso marker="sys"><c>sys(3)</c></seealso>. The <c>sys</c> module
can be used for debugging an event manager.</p>
<p>Notice that an event manager <em>does</em> trap exit signals
automatically.</p>
<p>The <c>gen_event</c> process can go into hibernation
(see <seealso marker="erts:erlang#hibernate/3">
<c>erlang:hibernate/3</c></seealso>) if a callback function in
a handler module specifies <c>hibernate</c> in its return value.
This can be useful if the server is expected to be idle for a long
time. However, use this feature with care, as hibernation
implies at least two garbage collections (when hibernating and
shortly after waking up) and is not something you want to do
between each event handled by a busy event manager.</p>
<p>Notice that when multiple event handlers are
invoked, it is sufficient that one single event handler returns a
<c>hibernate</c> request for the whole event manager to go into
hibernation.</p>
<p>Unless otherwise stated, all functions in this module fail if
the specified event manager does not exist or if bad arguments are
specified.</p>
</description>
<datatypes>
<datatype>
<name name="handler"/>
</datatype>
<datatype>
<name name="handler_args"/>
</datatype>
<datatype>
<name name="add_handler_ret"/>
</datatype>
<datatype>
<name name="del_handler_ret"/>
</datatype>
</datatypes>
<funcs>
<func>
<name>add_handler(EventMgrRef, Handler, Args) -> Result</name>
<fsummary>Add an event handler to a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args = term()</v>
<v>Result = ok | {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Adds a new event handler to event manager <c>EventMgrRef</c>.
The event manager calls
<seealso marker="#Module:init/1"><c>Module:init/1</c></seealso>
to initiate the event handler and its internal state.</p>
<p><c>EventMgrRef</c> can be any of the following:</p>
<list type="bulleted">
<item>The pid</item>
<item><c>Name</c>, if the event manager is locally registered</item>
<item><c>{Name,Node}</c>, if the event manager is locally
registered at another node</item>
<item><c>{global,GlobalName}</c>, if the event manager is globally
registered</item>
<item><c>{via,Module,ViaName}</c>, if the event manager is registered
through an alternative process registry</item>
</list>
<p><c>Handler</c> is the name of the callback module <c>Module</c> or
a tuple <c>{Module,Id}</c>, where <c>Id</c> is any term.
The <c>{Module,Id}</c> representation makes it possible to
identify a specific event handler when many event handlers
use the same callback module.</p>
<p><c>Args</c> is any term that is passed as the argument
to <c>Module:init/1</c>.</p>
<p>If <c>Module:init/1</c> returns a correct value indicating
successful completion, the event manager adds the event
handler and this function returns
<c>ok</c>. If <c>Module:init/1</c> fails with <c>Reason</c> or
returns <c>{error,Reason}</c>, the event handler is
ignored and this function returns <c>{'EXIT',Reason}</c> or
<c>{error,Reason}</c>, respectively.</p>
</desc>
</func>
<func>
<name>add_sup_handler(EventMgrRef, Handler, Args) -> Result</name>
<fsummary>Add a supervised event handler to a generic event manager.
</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args = term()</v>
<v>Result = ok | {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Adds a new event handler in the same way as
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>,
but also supervises the connection between the event handler
and the calling process.</p>
<list type="bulleted">
<item>If the calling process later terminates with <c>Reason</c>,
the event manager deletes the event handler by calling
<seealso marker="#Module:terminate/2">
<c>Module:terminate/2</c></seealso>
with <c>{stop,Reason}</c> as argument.
</item>
<item>
<p>If the event handler is deleted later, the event manager
sends a message<c>{gen_event_EXIT,Handler,Reason}</c> to
the calling process. <c>Reason</c> is one of the following:</p>
<list type="bulleted">
<item>
<p><c>normal</c>, if the event handler has been removed
because of a
call to <c>delete_handler/3</c>, or <c>remove_handler</c>
has been returned by a callback function (see below).</p>
</item>
<item>
<p><c>shutdown</c>, if the event handler has been removed
because the event manager is terminating.</p>
</item>
<item>
<p><c>{swapped,NewHandler,Pid}</c>, if the process <c>Pid</c>
has replaced the event handler with another event handler
<c>NewHandler</c> using a call to
<seealso marker="#swap_handler/3">
<c>swap_handler/3</c></seealso> or
<seealso marker="#swap_sup_handler/3">
<c>swap_sup_handler/3</c></seealso>.</p>
</item>
<item>
<p>A term, if the event handler is removed because of an error.
Which term depends on the error.</p></item>
</list>
</item>
</list>
<p>For a description of the arguments and return values, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
</desc>
</func>
<func>
<name>call(EventMgrRef, Handler, Request) -> Result</name>
<name>call(EventMgrRef, Handler, Request, Timeout) -> Result</name>
<fsummary>Make a synchronous call to a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Request = term()</v>
<v>Timeout = int()>0 | infinity</v>
<v>Result = Reply | {error,Error}</v>
<v> Reply = term()</v>
<v> Error = bad_module | {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Makes a synchronous call to event handler <c>Handler</c>
installed in event manager <c>EventMgrRef</c> by sending a
request and waiting until a reply arrives or a time-out occurs.
The event manager calls <seealso marker="#Module:handle_call/2">
<c>Module:handle_call/2</c></seealso> to handle the request.</p>
<p>For a description of <c>EventMgrRef</c> and <c>Handler</c>, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
<p><c>Request</c> is any term that is passed as one of
the arguments to <c>Module:handle_call/2</c>.</p>
<p><c>Timeout</c> is an integer greater than zero that specifies
how many milliseconds to wait for a reply, or the atom
<c>infinity</c> to wait indefinitely. Defaults to 5000.
If no reply is received within the specified time, the function
call fails.</p>
<p>The return value <c>Reply</c> is defined in the return value of
<c>Module:handle_call/2</c>. If the specified event handler is not
installed, the function returns <c>{error,bad_module}</c>. If
the callback function fails with <c>Reason</c> or returns an
unexpected value <c>Term</c>, this function returns
<c>{error,{'EXIT',Reason}}</c> or <c>{error,Term}</c>,
respectively.</p>
</desc>
</func>
<func>
<name>delete_handler(EventMgrRef, Handler, Args) -> Result</name>
<fsummary>Delete an event handler from a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args = term()</v>
<v>Result = term() | {error,module_not_found} | {'EXIT',Reason}</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Deletes an event handler from event manager
<c>EventMgrRef</c>. The event manager calls
<seealso marker="#Module:terminate/2">
<c>Module:terminate/2</c></seealso> to terminate the event
handler.</p>
<p>For a description of <c>EventMgrRef</c> and <c>Handler</c>, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
<p><c>Args</c> is any term that is passed as one of
the arguments to <c>Module:terminate/2</c>.</p>
<p>The return value is the return value of <c>Module:terminate/2</c>.
If the specified event handler is not installed, the function
returns <c>{error,module_not_found}</c>. If the callback function
fails with <c>Reason</c>, the function returns
<c>{'EXIT',Reason}</c>.</p>
</desc>
</func>
<func>
<name>notify(EventMgrRef, Event) -> ok</name>
<name>sync_notify(EventMgrRef, Event) -> ok</name>
<fsummary>Notify an event manager about an event.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Event = term()</v>
</type>
<desc>
<p>Sends an event notification to event manager
<c>EventMgrRef</c>. The event manager calls
<seealso marker="#Module:handle_event/2">
<c>Module:handle_event/2</c></seealso>
for each installed event handler to handle the event.</p>
<p><c>notify/2</c> is asynchronous and returns immediately after
the event notification has been sent. <c>sync_notify/2</c> is
synchronous in the sense that it returns <c>ok</c> after
the event has been handled by all event handlers.</p>
<p>For a description of <c>EventMgrRef</c>, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
<p><c>Event</c> is any term that is passed as one of
the arguments to <seealso marker="#Module:handle_event/2">
<c>Module:handle_event/2</c></seealso>.</p>
<p><c>notify/1</c> does not fail even if the specified event manager
does not exist, unless it is specified as <c>Name</c>.</p>
</desc>
</func>
<func>
<name>start() -> Result</name>
<name>start(EventMgrName | Options) -> Result</name>
<name>start(EventMgrName, Options) -> Result</name>
<fsummary>Create a stand-alone event manager process.</fsummary>
<type>
<v>EventMgrName = {local,Name} | {global,GlobalName} | {via,Module,ViaName}</v>
<v> Name = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Options = [Option]</v>
<v> Option = {debug,Dbgs} | {timeout,Time} | {spawn_opt,SOpts}</v>
<v> Dbgs = [Dbg]</v>
<v> Dbg = trace | log | statistics | {log_to_file,FileName} | {install,{Func,FuncState}}</v>
<v> SOpts = [term()]</v>
<v>Result = {ok,Pid} | {error,{already_started,Pid}}</v>
<v> Pid = pid()</v>
</type>
<desc>
<p>Creates a stand-alone event manager process, that is, an event
manager that is not part of a supervision tree and thus has
no supervisor.</p>
<p>For a description of the arguments and return values, see
<seealso marker="#start_link/0"><c>start_link/0,1</c></seealso>.</p>
</desc>
</func>
<func>
<name>start_link() -> Result</name>
<name>start_link(EventMgrName | Options) -> Result</name>
<name>start_link(EventMgrName, Options) -> Result</name>
<fsummary>Create a generic event manager process in a supervision tree.
</fsummary>
<type>
<v>EventMgrName = {local,Name} | {global,GlobalName} | {via,Module,ViaName}</v>
<v> Name = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Options = [Option]</v>
<v> Option = {debug,Dbgs} | {timeout,Time} | {spawn_opt,SOpts}</v>
<v> Dbgs = [Dbg]</v>
<v> Dbg = trace | log | statistics | {log_to_file,FileName} | {install,{Func,FuncState}}</v>
<v> SOpts = [term()]</v>
<v>Result = {ok,Pid} | {error,{already_started,Pid}}</v>
<v> Pid = pid()</v>
</type>
<desc>
<p>Creates an event manager process as part of a supervision
tree. The function is to be called, directly or indirectly,
by the supervisor. For example, it ensures that
the event manager is linked to the supervisor.</p>
<list type="bulleted">
<item>
<p>If <c>EventMgrName={local,Name}</c>, the event manager is
registered locally as <c>Name</c> using <c>register/2</c>.</p>
</item>
<item>
<p>If <c>EventMgrName={global,GlobalName}</c>, the event manager is
registered globally as <c>GlobalName</c> using
<seealso marker="kernel:global#register_name/2">
<c>global:register_name/2</c></seealso>.
If no name is provided, the event manager is not registered.</p>
</item>
<item>
<p>If <c>EventMgrName={via,Module,ViaName}</c>, the event manager
registers with the registry represented by <c>Module</c>.
The <c>Module</c> callback is to export the functions
<c>register_name/2</c>, <c>unregister_name/1</c>,
<c>whereis_name/1</c>, and <c>send/2</c>, which are to behave
as the corresponding functions in
<seealso marker="kernel:global"><c>global</c></seealso>.
Thus, <c>{via,global,GlobalName}</c> is a valid reference.</p>
</item>
</list>
<p>If the event manager is successfully created, the function
returns <c>{ok,Pid}</c>, where <c>Pid</c> is the pid of
the event manager. If a process with the specified
<c>EventMgrName</c> exists already, the function returns
<c>{error,{already_started,Pid}}</c>, where <c>Pid</c> is
the pid of that process.</p>
</desc>
</func>
<func>
<name>stop(EventMgrRef) -> ok</name>
<name>stop(EventMgrRef, Reason, Timeout) -> ok</name>
<fsummary>Terminate a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v>Name = Node = atom()</v>
<v>GlobalName = ViaName = term()</v>
<v>Reason = term()</v>
<v>Timeout = int()>0 | infinity</v>
</type>
<desc>
<p>Orders event manager <c>EventMgrRef</c> to exit with
the specifies <c>Reason</c> and waits for it to
terminate. Before terminating, <c>gen_event</c> calls
<seealso marker="#Module:terminate/2">
<c>Module:terminate(stop,...)</c></seealso>
for each installed event handler.</p>
<p>The function returns <c>ok</c> if the event manager terminates
with the expected reason. Any other reason than <c>normal</c>,
<c>shutdown</c>, or <c>{shutdown,Term}</c> causes an
error report to be issued using
<seealso marker="kernel:error_logger#format/2">
<c>error_logger:format/2</c></seealso>.
The default <c>Reason</c> is <c>normal</c>.</p>
<p><c>Timeout</c> is an integer greater than zero that
specifies how many milliseconds to wait for the event manager to
terminate, or the atom <c>infinity</c> to wait
indefinitely. Defaults to <c>infinity</c>. If the
event manager has not terminated within the specified time, a
<c>timeout</c> exception is raised.</p>
<p>If the process does not exist, a <c>noproc</c> exception
is raised.</p>
<p>For a description of <c>EventMgrRef</c>, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
</desc>
</func>
<func>
<name>swap_handler(EventMgrRef, {Handler1,Args1}, {Handler2,Args2}) -> Result</name>
<fsummary>Replace an event handler in a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler1 = Handler2 = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args1 = Args2 = term()</v>
<v>Result = ok | {error,Error}</v>
<v> Error = {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Replaces an old event handler with a new event handler in
event manager <c>EventMgrRef</c>.</p>
<p>For a description of the arguments, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
<p>First the old event handler <c>Handler1</c> is deleted.
The event manager calls <c>Module1:terminate(Args1, ...)</c>,
where <c>Module1</c> is the callback module of <c>Handler1</c>,
and collects the return value.</p>
<p>Then the new event handler <c>Handler2</c> is added and initiated
by calling <c>Module2:init({Args2,Term})</c>, where <c>Module2</c>
is the callback module of <c>Handler2</c> and <c>Term</c> is
the return value of <c>Module1:terminate/2</c>. This makes it
possible to transfer information from <c>Handler1</c> to
<c>Handler2</c>.</p>
<p>The new handler is added even if the the specified old event
handler is not installed, in which case <c>Term=error</c>, or if
<c>Module1:terminate/2</c> fails with <c>Reason</c>,
in which case <c>Term={'EXIT',Reason}</c>.
The old handler is deleted even if <c>Module2:init/1</c> fails.</p>
<p>If there was a supervised connection between <c>Handler1</c> and
a process <c>Pid</c>, there is a supervised connection
between <c>Handler2</c> and <c>Pid</c> instead.</p>
<p>If <c>Module2:init/1</c> returns a correct value, this function
returns <c>ok</c>. If <c>Module2:init/1</c> fails with
<c>Reason</c> or returns an unexpected value <c>Term</c>,
this function returns <c>{error,{'EXIT',Reason}}</c> or
<c>{error,Term}</c>, respectively.</p>
</desc>
</func>
<func>
<name>swap_sup_handler(EventMgrRef, {Handler1,Args1}, {Handler2,Args2}) -> Result</name>
<fsummary>Replace an event handler in a generic event manager.</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler1 = Handler 2 = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
<v>Args1 = Args2 = term()</v>
<v>Result = ok | {error,Error}</v>
<v> Error = {'EXIT',Reason} | term()</v>
<v> Reason = term()</v>
</type>
<desc>
<p>Replaces an event handler in event manager <c>EventMgrRef</c>
in the same way as <c>swap_handler/3</c>, but also supervises
the connection between <c>Handler2</c> and the calling process.</p>
<p>For a description of the arguments and return values, see
<seealso marker="#swap_handler/3"><c>swap_handler/3</c></seealso>.</p>
</desc>
</func>
<func>
<name>which_handlers(EventMgrRef) -> [Handler]</name>
<fsummary>Return all event handlers installed in a generic event manager.
</fsummary>
<type>
<v>EventMgrRef = Name | {Name,Node} | {global,GlobalName}
| {via,Module,ViaName} | pid()</v>
<v> Name = Node = atom()</v>
<v> GlobalName = ViaName = term()</v>
<v>Handler = Module | {Module,Id}</v>
<v> Module = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>Returns a list of all event handlers installed in event
manager <c>EventMgrRef</c>.</p>
<p>For a description of <c>EventMgrRef</c> and <c>Handler</c>, see
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso>.</p>
</desc>
</func>
</funcs>
<section>
<title>Callback Functions</title>
<p>The following functions are to be exported from a <c>gen_event</c>
callback module.</p>
</section>
<funcs>
<func>
<name>Module:code_change(OldVsn, State, Extra) -> {ok, NewState}</name>
<fsummary>Update the internal state during upgrade/downgrade.</fsummary>
<type>
<v>OldVsn = Vsn | {down, Vsn}</v>
<v> Vsn = term()</v>
<v>State = NewState = term()</v>
<v>Extra = term()</v>
</type>
<desc>
<note>
<p>This callback is optional, so callback modules need not export it.
If a release upgrade/downgrade with <c>Change={advanced,Extra}</c>
specified in the <c>.appup</c> file is made when <c>code_change/3</c>
isn't implemented the event handler will crash with an <c>undef</c> error
reason.</p>
</note>
<p>This function is called for an installed event handler that
is to update its internal state during a release
upgrade/downgrade, that is, when the instruction
<c>{update,Module,Change,...}</c>, where
<c>Change={advanced,Extra}</c>, is specified in the <c>.appup</c>
file. For more information, see <seealso
marker="doc/design_principles:users_guide">OTP Design Principles</seealso>.</p>
<p>For an upgrade, <c>OldVsn</c> is <c>Vsn</c>, and for a downgrade,
<c>OldVsn</c> is <c>{down,Vsn}</c>. <c>Vsn</c> is defined by the
<c>vsn</c> attribute(s) of the old version of the callback module
<c>Module</c>. If no such attribute is defined, the version
is the checksum of the Beam file.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p><c>Extra</c> is passed "as is" from the <c>{advanced,Extra}</c>
part of the update instruction.</p>
<p>The function is to return the updated internal state.</p>
</desc>
</func>
<func>
<name>Module:format_status(Opt, [PDict, State]) -> Status</name>
<fsummary>Optional function for providing a term describing the
current event handler state.</fsummary>
<type>
<v>Opt = normal | terminate</v>
<v>PDict = [{Key, Value}]</v>
<v>State = term()</v>
<v>Status = term()</v>
</type>
<desc>
<note>
<p>This callback is optional, so event handler modules need
not export it. If a handler does not export this function,
the <c>gen_event</c> module uses the handler state directly for
the purposes described below.</p>
</note>
<p>This function is called by a <c>gen_event</c> process in the
following situations:</p>
<list type="bulleted">
<item>One of <seealso marker="sys#get_status/1">
<c>sys:get_status/1,2</c></seealso>
is invoked to get the <c>gen_event</c> status. <c>Opt</c> is set
to the atom <c>normal</c> for this case.</item>
<item>The event handler terminates abnormally and <c>gen_event</c>
logs an error. <c>Opt</c> is set to the
atom <c>terminate</c> for this case.</item>
</list>
<p>This function is useful for changing the form and
appearance of the event handler state for these cases. An
event handler callback module wishing to change the
the <c>sys:get_status/1,2</c> return value as well as how
its state appears in termination error logs, exports an
instance of <c>format_status/2</c> that returns a term
describing the current state of the event handler.</p>
<p><c>PDict</c> is the current value of the
process dictionary of <c>gen_event</c>.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p>The function is to return <c>Status</c>, a term that
change the details of the current state of the event
handler. Any term is allowed for <c>Status</c>. The
<c>gen_event</c> module uses <c>Status</c> as follows:</p>
<list type="bulleted">
<item><p>When <c>sys:get_status/1,2</c> is called, <c>gen_event</c>
ensures that its return value contains <c>Status</c> in
place of the state term of the event handler.</p></item>
<item><p>When an event handler terminates abnormally, <c>gen_event</c>
logs <c>Status</c> in place of the state term of the
event handler.</p></item>
</list>
<p>One use for this function is to return compact alternative
state representations to avoid that large state terms
are printed in log files.</p>
</desc>
</func>
<func>
<name>Module:handle_call(Request, State) -> Result</name>
<fsummary>Handle a synchronous request.</fsummary>
<type>
<v>Request = term()</v>
<v>State = term()</v>
<v>Result = {ok,Reply,NewState} | {ok,Reply,NewState,hibernate}</v>
<v> | {swap_handler,Reply,Args1,NewState,Handler2,Args2}</v>
<v> | {remove_handler, Reply}</v>
<v> Reply = term()</v>
<v> NewState = term()</v>
<v> Args1 = Args2 = term()</v>
<v> Handler2 = Module2 | {Module2,Id}</v>
<v> Module2 = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>Whenever an event manager receives a request sent using
<seealso marker="#call/3"><c>call/3,4</c></seealso>,
this function is called for
the specified event handler to handle the request.</p>
<p><c>Request</c> is the <c>Request</c> argument of <c>call/3,4</c>.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p>The return values are the same as for
<seealso marker="#Module:handle_event/2">
<c>Module:handle_event/2</c></seealso>
except that they also contain a term <c>Reply</c>, which is the reply
to the client as the return value of <c>call/3,4</c>.</p>
</desc>
</func>
<func>
<name>Module:handle_event(Event, State) -> Result</name>
<fsummary>Handle an event.</fsummary>
<type>
<v>Event = term()</v>
<v>State = term()</v>
<v>Result = {ok,NewState} | {ok,NewState,hibernate} </v>
<v> | {swap_handler,Args1,NewState,Handler2,Args2}
| remove_handler</v>
<v> NewState = term()</v>
<v> Args1 = Args2 = term()</v>
<v> Handler2 = Module2 | {Module2,Id}</v>
<v> Module2 = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<p>Whenever an event manager receives an event sent using
<seealso marker="#notify/2"><c>notify/2</c></seealso> or
<seealso marker="#sync_notify/2"><c>sync_notify/2</c></seealso>,
this function is called for each installed event handler to handle
the event.</p>
<p><c>Event</c> is the <c>Event</c> argument of
<c>notify/2</c>/<c>sync_notify/2</c>.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<list type="bulleted">
<item>
<p>If <c>{ok,NewState}</c> or <c>{ok,NewState,hibernate}</c>
is returned, the event handler
remains in the event manager with the possible updated
internal state <c>NewState</c>.</p>
</item>
<item>
<p>If <c>{ok,NewState,hibernate}</c> is returned, the event
manager also goes into hibernation (by calling
<seealso marker="proc_lib#hibernate/3">
<c>proc_lib:hibernate/3</c></seealso>), waiting for the next
event to occur. It is sufficient that one of the
event handlers return <c>{ok,NewState,hibernate}</c> for the
whole event manager process to hibernate.</p>
</item>
<item>
<p>If <c>{swap_handler,Args1,NewState,Handler2,Args2}</c> is
returned, the event handler is replaced by <c>Handler2</c> by
first calling <c>Module:terminate(Args1,NewState)</c> and then
<c>Module2:init({Args2,Term})</c>, where <c>Term</c> is the return
value of <c>Module:terminate/2</c>. For more information, see
<seealso marker="#swap_handler/3"><c>swap_handler/3</c></seealso>.
</p>
</item>
<item>
<p>If <c>remove_handler</c> is returned, the event handler is
deleted by calling
<c>Module:terminate(remove_handler,State)</c>.</p>
</item>
</list>
</desc>
</func>
<func>
<name>Module:handle_info(Info, State) -> Result</name>
<fsummary>Handle an incoming message.</fsummary>
<type>
<v>Info = term()</v>
<v>State = term()</v>
<v>Result = {ok,NewState} | {ok,NewState,hibernate}</v>
<v> | {swap_handler,Args1,NewState,Handler2,Args2}
| remove_handler</v>
<v> NewState = term()</v>
<v> Args1 = Args2 = term()</v>
<v> Handler2 = Module2 | {Module2,Id}</v>
<v> Module2 = atom()</v>
<v> Id = term()</v>
</type>
<desc>
<note>
<p>This callback is optional, so callback modules need not
export it. The <c>gen_event</c> module provides a default
implementation of this function that logs about the unexpected
<c>Info</c> message, drops it and returns <c>{noreply, State}</c>.</p>
</note>
<p>This function is called for each installed event handler when
an event manager receives any other message than an event or
a synchronous request (or a system message).</p>
<p><c>Info</c> is the received message.</p>
<p>For a description of <c>State</c> and possible return values, see
<seealso marker="#Module:handle_event/2">
<c>Module:handle_event/2</c></seealso>.</p>
</desc>
</func>
<func>
<name>Module:init(InitArgs) -> {ok,State} | {ok,State,hibernate} | {error,Reason}</name>
<fsummary>Initialize an event handler.</fsummary>
<type>
<v>InitArgs = Args | {Args,Term}</v>
<v> Args = Term = term()</v>
<v>State = term()</v>
<v>Reason = term()</v>
</type>
<desc>
<p>Whenever a new event handler is added to an event manager,
this function is called to initialize the event handler.</p>
<p>If the event handler is added because of a call to
<seealso marker="#add_handler/3"><c>add_handler/3</c></seealso> or
<seealso marker="#add_sup_handler/3">
<c>add_sup_handler/3</c></seealso>, <c>InitArgs</c> is
the <c>Args</c> argument of these functions.</p>
<p>If the event handler replaces another event handler because of
a call to
<seealso marker="#swap_handler/3"><c>swap_handler/3</c></seealso> or
<seealso marker="#swap_sup_handler/3">
<c>swap_sup_handler/3</c></seealso>, or because of a <c>swap</c>
return tuple from one of the other callback functions,
<c>InitArgs</c> is a tuple <c>{Args,Term}</c>, where <c>Args</c> is
the argument provided in the function call/return tuple and
<c>Term</c> is the result of terminating the old event handler, see
<seealso marker="#swap_handler/3"><c>swap_handler/3</c></seealso>.</p>
<p>If successful, the function returns <c>{ok,State}</c>
or <c>{ok,State,hibernate}</c>, where <c>State</c> is the
initial internal state of the event handler.</p>
<p>If <c>{ok,State,hibernate}</c> is returned, the event
manager goes into hibernation (by calling <seealso
marker="proc_lib#hibernate/3"><c>proc_lib:hibernate/3</c></seealso>),
waiting for the next event to occur.</p>
</desc>
</func>
<func>
<name>Module:terminate(Arg, State) -> term()</name>
<fsummary>Clean up before deletion.</fsummary>
<type>
<v>Arg = Args | {stop,Reason} | stop | remove_handler</v>
<v> | {error,{'EXIT',Reason}} | {error,Term}</v>
<v> Args = Reason = Term = term()</v>
</type>
<desc>
<note>
<p>This callback is optional, so callback modules need not
export it. The <c>gen_event</c> module provides a default
implementation without cleanup.</p>
</note>
<p>Whenever an event handler is deleted from an event manager,
this function is called. It is to be the opposite of
<seealso marker="#Module:init/1"><c>Module:init/1</c></seealso>
and do any necessary cleaning up.</p>
<p>If the event handler is deleted because of a call to
<seealso marker="#delete_handler/3"><c>delete_handler/3</c></seealso>,
<seealso marker="#swap_handler/3"><c>swap_handler/3</c></seealso>, or
<seealso marker="#swap_sup_handler/3">
<c>swap_sup_handler/3</c></seealso>, <c>Arg</c> is
the <c>Args</c> argument of this function call.</p>
<p><c>Arg={stop,Reason}</c> if the event handler has a supervised
connection to a process that has terminated with reason
<c>Reason</c>.</p>
<p><c>Arg=stop</c> if the event handler is deleted because
the event manager is terminating.</p>
<p>The event manager terminates if it is part of a supervision
tree and it is ordered by its supervisor to terminate.
Even if it is <em>not</em> part of a supervision tree, it
terminates if it receives an <c>'EXIT'</c> message from
its parent.</p>
<p><c>Arg=remove_handler</c> if the event handler is deleted because
another callback function has returned <c>remove_handler</c> or
<c>{remove_handler,Reply}</c>.</p>
<p><c>Arg={error,Term}</c> if the event handler is deleted because
a callback function returned an unexpected value <c>Term</c>,
or <c>Arg={error,{'EXIT',Reason}}</c> if a callback function
failed.</p>
<p><c>State</c> is the internal state of the event handler.</p>
<p>The function can return any term. If the event handler is
deleted because of a call to <c>gen_event:delete_handler/3</c>,
the return value of that function becomes the return value of this
function. If the event handler is to be replaced with another event
handler because of a swap, the return value is passed to
the <c>init</c> function of the new event handler. Otherwise
the return value is ignored.</p>
</desc>
</func>
</funcs>
<section>
<title>See Also</title>
<p><seealso marker="supervisor"><c>supervisor(3)</c></seealso>,
<seealso marker="sys"><c>sys(3)</c></seealso></p>
</section>
</erlref>
|