diff options
author | Erlang/OTP <[email protected]> | 2011-10-04 12:06:58 +0200 |
---|---|---|
committer | Erlang/OTP <[email protected]> | 2011-10-04 12:06:58 +0200 |
commit | b6dc1a844eab061d0a7153d46e7e68296f15a504 (patch) | |
tree | abb46e1ccc6df3f56965fe78b2861b93a0271d3e /lib/common_test/doc/src/notes.xml | |
parent | 3d6153cb2d3a08f9b82a3ea52e69c5442c226559 (diff) | |
download | otp-OTP_R14B04.tar.gz otp-OTP_R14B04.tar.bz2 otp-OTP_R14B04.zip |
Prepare releaseOTP_R14B04
Diffstat (limited to 'lib/common_test/doc/src/notes.xml')
-rw-r--r-- | lib/common_test/doc/src/notes.xml | 223 |
1 files changed, 223 insertions, 0 deletions
diff --git a/lib/common_test/doc/src/notes.xml b/lib/common_test/doc/src/notes.xml index 826b3c598d..af96ef621f 100644 --- a/lib/common_test/doc/src/notes.xml +++ b/lib/common_test/doc/src/notes.xml @@ -32,6 +32,229 @@ <file>notes.xml</file> </header> +<section><title>Common_Test 1.5.5</title> + + <section><title>Fixed Bugs and Malfunctions</title> + <list> + <item> + <p> + An error in how comments are colored in the test suite + overview html log file has been corrected. As result, a + new framework callback function, format_comment/1, has + been introduced.</p> + <p> + Own Id: OTP-9237</p> + </item> + <item> + <p> + Automatically generated init- and end-configuration + functions for test case groups caused incorrect execution + order of test cases. This has been corrected.</p> + <p> + Own Id: OTP-9369</p> + </item> + <item> + <p> + If multiple directories were specified with the 'logdir' + flag/option, Common Test would crash. This has been fixed + so that an error is properly reported instead.</p> + <p> + Own Id: OTP-9370</p> + </item> + <item> + <p> + If ct:log/2 was called with bad arguments, this could + cause the Common Test IO handling process to crash. This + fault has been corrected.</p> + <p> + Own Id: OTP-9371 Aux Id: OTP-8933 </p> + </item> + <item> + <p> + A bug has been fixed that made Test Server call the + end_tc/3 framework function with an incorrect module name + as first argument.</p> + <p> + Own Id: OTP-9379 Aux Id: seq11863 </p> + </item> + <item> + <p> + If a timetrap timeout occured during execution of of a + function in a lib module (i.e. a function called directly + or indirectly from a test case), the Suite argument in + the end_tc/3 framework callback function would not + correctly contain the name of the test suite, but the lib + module. (This would only happen if the lib module was + compiled with ct.hrl included). This error has been + solved.</p> + <p> + Own Id: OTP-9398</p> + </item> + <item> + <p> + Corrections of the vts mode. It will now report errors + (about e.g. incorrect config files) instead of crashing + or hanging. Furthermore, the requirement that the test + directory name must have a "_test" suffix has been + removed. Also, a workaround has been implemented for the + limitation that the file browser (in many web browsers) + will only return the basic file name, not the full + directory path (which made it impossible to have config + files in other directories than the main test directory).</p> + <p> + Own Id: OTP-9429</p> + </item> + <item> + <p> + Add a proplist() type</p> + <p> + Recently I was adding specs to an API and found that + there is no canonical proplist() type defined. (Thanks to + Ryan Zezeski)</p> + <p> + Own Id: OTP-9499</p> + </item> + <item> + <p> + It is now possible to use the 'step' flag/option to run + the debugger for test suites that contain test case + groups. This previously caused Common Test to crash. If + 'step config' is specified, breakpoints are now also + automatically set on init_per_group and end_per_group. + Note that breakpoints are always set automatically on + test case functions and this is true also for grouped + cases.</p> + <p> + Own Id: OTP-9518 Aux Id: OTP-8933 </p> + </item> + <item> + <p> + The test index page was not refreshed at the start of + each test suite which made it impossible to follow test + execution by means of refreshing the browser window (no + links to follow). This has been fixed.</p> + <p> + Own Id: OTP-9520 Aux Id: OTP-8933 </p> + </item> + <item> + <p> + If a test suite would start with a test case group + defined without the init_per_group/2 and end_per_group/2 + function, init_per_suite/1 would not execute initially + and logging of the test run would fail. This error has + been fixed.</p> + <p> + Own Id: OTP-9584</p> + </item> + <item> + <p> + The "Missing Suites" link from the top level index page + was incorrect and has been fixed.</p> + <p> + Own Id: OTP-9592</p> + </item> + </list> + </section> + + + <section><title>Improvements and New Features</title> + <list> + <item> + <p> + Various corrections and updates to improve the handling + and reporting of errors.</p> + <p> + Own Id: OTP-8933</p> + </item> + <item> + <p> + The dir and suite start option can now be used in + combination. E.g. executing my_SUITE in directory + my_tests can either be specified as "ct_run -suite + my_tests/my_SUITE" or as "ct_run -dir my_tests -suite + my_SUITE". Furthermore, the specification: + ct:run_test([{suite,["./my_SUITE"]},{testcase,t1}]) is + now interpreted as + ct:run_test([{suite,"./my_SUITE"},{testcase,t1}]), i.e. + only testcase t1 in test suite my_SUITE - not all cases - + will be executed.</p> + <p> + Own Id: OTP-9155</p> + </item> + <item> + <p> + A new option, 'logopts', has been introduced, to make it + possible to modify some aspects of the logging behaviour + in Common Test (or Test Server). For example, whenever an + io printout is made, test_server adds newline (\n) to the + end of the output string. This may not always be a + preferred action and can therefore be disabled by means + of "ct_run ... -logopts no_nl" (or ct:run_test([..., + {logopts,[no_nl]}])). A new framework callback function, + get_logopts/0, has been introduced (see the ct_framework + module for details).</p> + <p> + Own Id: OTP-9372 Aux Id: OTP-9396 </p> + </item> + <item> + <p> + A new option, 'logopts', has been introduced, to make it + possible to modify some aspects of the logging behaviour + in Common Test (or Test Server). For example, if the html + version of the test suite source code should not be + generated during the test run (and consequently be + unavailable in the log file system), the feature may be + disabled by means of "ct_run ... -logopts no_src" (or + ct:run_test([..., {logopts,[no_src]}])). A new framework + callback function, get_logopts/0, has been introduced + (see the ct_framework module for details).</p> + <p> + Own Id: OTP-9396 Aux Id: seq11869, OTP-9372 </p> + </item> + <item> + <p> + CT Hooks can now be assigned a priority. The priority of + a CTH determines when it should execute in relation to + other CTHs. The CTH with the lowest priority will be + executed first, CTHs with equal priority will be executed + in the order which they were installed.</p> + <p> + Own Id: OTP-9445</p> + </item> + <item> + <p> + It is now possible to use a tuple {M,F,A}, or a fun, as + timetrap specification in the suite info function or test + case info functions. The function must return a valid + timeout value, as documented in the common_test man page + and in the User's Guide.</p> + <p> + Own Id: OTP-9501 Aux Id: seq11894 </p> + </item> + <item> + <p> + A new built-in common test hook has been added which + captures error_logger and SASL event and prints them in + the testcase log. To disable this (and any other built-in + hooks) pass 'enable_builtin_hooks false' to common test.</p> + <p> + Own Id: OTP-9543</p> + </item> + <item> + <p> + Common Test now has the possibility to have built-in + hooks which are started by default when any test is run. + To disable built-in hooks pass 'enable_builtin_hooks + false' to common test. See the common test hooks + documentation for more details.</p> + <p> + Own Id: OTP-9564</p> + </item> + </list> + </section> + +</section> + <section><title>Common_Test 1.5.4</title> <section><title>Fixed Bugs and Malfunctions</title> |