1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
|
<?xml version="1.0" encoding="utf-8" ?>
<!DOCTYPE erlref SYSTEM "erlref.dtd">
<erlref>
<header>
<copyright>
<year>2006</year><year>2017</year>
<holder>Ericsson AB. All Rights Reserved.</holder>
</copyright>
<legalnotice>
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
</legalnotice>
<title>dialyzer</title>
<prepared></prepared>
<docno></docno>
<date>2016-09-20</date>
<rev></rev>
<file>dialyzer.xml</file>
</header>
<module>dialyzer</module>
<modulesummary>Dialyzer, a DIscrepancy AnaLYZer for ERlang programs.
</modulesummary>
<description>
<p>Dialyzer is a static analysis tool that identifies software
discrepancies, such as definite type errors, code that has become dead
or unreachable because of programming error, and unnecessary tests,
in single Erlang modules or entire (sets of) applications.</p>
<p>Dialyzer starts its analysis from either
debug-compiled BEAM bytecode or from Erlang source code. The file
and line number of a discrepancy is reported along with an
indication of what the discrepancy is about. Dialyzer bases its
analysis on the concept of success typings, which allows for sound
warnings (no false positives).</p>
</description>
<section>
<marker id="command_line"></marker>
<title>Using Dialyzer from the Command Line</title>
<p>Dialyzer has a command-line version for automated use. This
section provides a brief description of the options. The same information
can be obtained by writing the following in a shell:</p>
<code type="none">
dialyzer --help</code>
<p>For more details about the operation of Dialyzer, see section
<seealso marker="dialyzer_chapter#dialyzer_gui">
Using Dialyzer from the GUI</seealso> in the User's Guide.</p>
<p><em>Exit status of the command-line version:</em></p>
<taglist>
<tag><c>0</c></tag>
<item>
<p>No problems were found during the analysis and no warnings were
emitted.</p>
</item>
<tag><c>1</c></tag>
<item>
<p>Problems were found during the analysis.</p>
</item>
<tag><c>2</c></tag>
<item>
<p>No problems were found during the analysis, but warnings were
emitted.</p>
</item>
</taglist>
<p><em>Usage:</em></p>
<code type="none">
dialyzer [--add_to_plt] [--apps applications] [--build_plt]
[--check_plt] [-Ddefine]* [-Dname] [--dump_callgraph file]
[files_or_dirs] [--fullpath] [--get_warnings] [--gui] [--help]
[-I include_dir]* [--no_check_plt] [--no_native]
[--no_native_cache] [-o outfile] [--output_plt file] [-pa dir]*
[--plt plt] [--plt_info] [--plts plt*] [--quiet] [-r dirs]
[--raw] [--remove_from_plt] [--shell] [--src] [--statistics]
[--verbose] [--version] [-Wwarn]*</code>
<note>
<p>* denotes that multiple occurrences of the option are possible.</p>
</note>
<p><em>Options:</em></p>
<taglist>
<tag><c>--add_to_plt</c></tag>
<item>
<p>The PLT is extended to also include the files specified with
<c>-c</c> and <c>-r</c>. Use
<c>--plt</c> to specify which PLT to start from,
and <c>--output_plt</c> to specify where to put the PLT.
Notice that the analysis possibly can include files from the PLT if
they depend on the new files. This option only works for BEAM
files.</p>
</item>
<tag><c>--apps applications</c></tag>
<item>
<p>This option is typically used when building or modifying a PLT as
in:</p>
<code type="none">
dialyzer --build_plt --apps erts kernel stdlib mnesia ...</code>
<p>to refer conveniently to library applications corresponding to the
Erlang/OTP installation. However, this option is general and can also
be used during analysis to refer to Erlang/OTP applications.
File or directory names can also be included, as in:</p>
<code type="none">
dialyzer --apps inets ssl ./ebin ../other_lib/ebin/my_module.beam</code>
</item>
<tag><c>--build_plt</c></tag>
<item>
<p>The analysis starts from an empty PLT and creates a new one from
the files specified with <c>-c</c> and
<c>-r</c>. This option only works for BEAM files.
To override the default PLT location, use
<c>--plt</c> or <c>--output_plt</c>.</p>
</item>
<tag><c>--check_plt</c></tag>
<item>
<p>Check the PLT for consistency and rebuild it if it is not
up-to-date.</p>
</item>
<tag><c>-Dname</c> (or <c>-Dname=value</c>)</tag>
<item>
<p>When analyzing from source, pass the define to Dialyzer.
(**)</p>
</item>
<tag><c>--dump_callgraph file</c></tag>
<item>
<p>Dump the call graph into the specified file whose format is
determined by the filename extension. Supported extensions are:
<c>raw</c>, <c>dot</c>, and <c>ps</c>. If something else is used as
filename extension, default format <c>.raw</c> is used.</p>
</item>
<tag><c>files_or_dirs</c> (for backward compatibility also
as <c>-c files_or_dirs</c>)</tag>
<item>
<p>Use Dialyzer from the command line to detect defects in the
specified files or directories containing <c>.erl</c> or
<c>.beam</c> files, depending on the type of the
analysis.</p>
</item>
<tag><c>--fullpath</c></tag>
<item>
<p>Display the full path names of files for which warnings are
emitted.</p>
</item>
<tag><c>--get_warnings</c></tag>
<item>
<p>Make Dialyzer emit warnings even when manipulating the PLT.
Warnings are only emitted for files that are analyzed.</p>
</item>
<tag><c>--gui</c></tag>
<item>
<p>Use the GUI.</p></item>
<tag><c>--help</c> (or <c>-h</c>)</tag>
<item>
<p>Print this message and exit.</p>
</item>
<tag><c>-I include_dir</c></tag>
<item>
<p>When analyzing from source, pass the <c>include_dir</c>
to Dialyzer. (**)</p>
</item>
<tag><c>--no_check_plt</c></tag>
<item>
<p>Skip the PLT check when running Dialyzer. This is useful when
working with installed PLTs that never change.</p>
</item>
<tag><c>--no_native</c> (or <c>-nn</c>)</tag>
<item>
<p>Bypass the native code compilation of some key files that
Dialyzer heuristically performs when dialyzing many files.
This avoids the compilation time, but can result in (much) longer
analysis time.</p>
</item>
<tag><c>--no_native_cache</c></tag>
<item>
<p>By default, Dialyzer caches the results of native compilation
in directory <c>$XDG_CACHE_HOME/erlang/dialyzer_hipe_cache</c>.
<c>XDG_CACHE_HOME</c> defaults to <c>$HOME/.cache</c>.
Use this option to disable caching.</p>
</item>
<tag><c>-o outfile</c> (or
<c>--output outfile</c>)</tag>
<item>
<p>When using Dialyzer from the command line, send the analysis
results to the specified outfile rather than to <c>stdout</c>.</p>
</item>
<tag><c>--output_plt file</c></tag>
<item>
<p>Store the PLT at the specified file after building it.</p>
</item>
<tag><c>-pa dir</c></tag>
<item>
<p>Include <c>dir</c> in the path for Erlang. This is useful
when analyzing files that have <c>-include_lib()</c>
directives.</p>
</item>
<tag><c>--plt plt</c></tag>
<item>
<p>Use the specified PLT as the initial PLT. If the PLT was built
during setup, the files are checked for consistency.</p>
</item>
<tag><c>--plt_info</c></tag>
<item>
<p>Make Dialyzer print information about the PLT and then quit.
The PLT can be specified with <c>--plt(s)</c>.</p>
</item>
<tag><c>--plts plt*</c></tag>
<item>
<p>Merge the specified PLTs to create the initial PLT. This requires
that the PLTs are disjoint (that is, do not have any module
appearing in more than one PLT).
The PLTs are created in the usual way:</p>
<code type="none">
dialyzer --build_plt --output_plt plt_1 files_to_include
...
dialyzer --build_plt --output_plt plt_n files_to_include</code>
<p>They can then be used in either of the following ways:</p>
<code type="none">
dialyzer files_to_analyze --plts plt_1 ... plt_n</code>
<p>or</p>
<code type="none">
dialyzer --plts plt_1 ... plt_n -- files_to_analyze</code>
<p>Notice the <c>--</c> delimiter in the second case.</p>
</item>
<tag><c>--quiet</c> (or <c>-q</c>)</tag>
<item>
<p>Make Dialyzer a bit more quiet.</p>
</item>
<tag><c>-r dirs</c></tag>
<item>
<p>Same as <c>files_or_dirs</c>, but the specified
directories are searched
recursively for subdirectories containing <c>.erl</c> or
<c>.beam</c> files in them, depending on the type of
analysis.</p>
</item>
<tag><c>--raw</c></tag>
<item>
<p>When using Dialyzer from the command line, output the raw
analysis results (Erlang terms) instead of the formatted result.
The raw format
is easier to post-process (for example, to filter warnings or to
output HTML pages).</p>
</item>
<tag><c>--remove_from_plt</c></tag>
<item>
<p>The information from the files specified with
<c>-c</c> and <c>-r</c> is removed from
the PLT. Notice that this can cause a reanalysis of the remaining
dependent files.</p>
</item>
<tag><c>--shell</c></tag>
<item>
<p>Do not disable the Erlang shell while running the GUI.</p>
</item>
<tag><c>--src</c></tag>
<item>
<p>Override the default, which is to analyze BEAM files, and
analyze starting from Erlang source code instead.</p>
</item>
<tag><c>--statistics</c></tag>
<item>
<p>Print information about the progress of execution (analysis phases,
time spent in each, and size of the relative input).</p>
</item>
<tag><c>--verbose</c></tag>
<item>
<p>Make Dialyzer a bit more verbose.</p>
</item>
<tag><c>--version</c> (or <c>-v</c>)</tag>
<item>
<p>Print the Dialyzer version and some more information and
exit.</p>
</item>
<tag><c>-Wwarn</c></tag>
<item>
<p>A family of options that selectively turn on/off warnings.
(For help on the names of warnings, use
<c>dialyzer -Whelp</c>.)
Notice that the options can also be specified in the file with a
<c>-dialyzer()</c> attribute. For details, see section <seealso
marker="#suppression">Requesting or Suppressing Warnings in
Source Files</seealso>.</p>
</item>
</taglist>
<note>
<p>** options <c>-D</c> and <c>-I</c> work both
from the command line and in the Dialyzer GUI; the syntax of
defines and includes is the same as that used by
<seealso marker="erts:erlc">erlc(1)</seealso>.</p>
</note>
<p><em>Warning options:</em></p>
<taglist>
<tag><c>-Werror_handling</c> (***)</tag>
<item>
<p>Include warnings for functions that only return by an exception.</p>
</item>
<tag><c>-Wno_behaviours</c></tag>
<item>
<p>Suppress warnings about behavior callbacks that drift from the
published recommended interfaces.</p>
</item>
<tag><c>-Wno_contracts</c></tag>
<item>
<p>Suppress warnings about invalid contracts.</p>
</item>
<tag><c>-Wno_fail_call</c></tag>
<item>
<p>Suppress warnings for failing calls.</p>
</item>
<tag><c>-Wno_fun_app</c></tag>
<item>
<p>Suppress warnings for fun applications that will fail.</p>
</item>
<tag><c>-Wno_improper_lists</c></tag>
<item>
<p>Suppress warnings for construction of improper lists.</p>
</item>
<tag><c>-Wno_match</c></tag>
<item>
<p>Suppress warnings for patterns that are unused or cannot match.</p>
</item>
<tag><c>-Wno_missing_calls</c></tag>
<item>
<p>Suppress warnings about calls to missing functions.</p>
</item>
<tag><c>-Wno_opaque</c></tag>
<item>
<p>Suppress warnings for violations of opacity of data types.</p>
</item>
<tag><c>-Wno_return</c></tag>
<item>
<p>Suppress warnings for functions that will never return a value.</p>
</item>
<tag><c>-Wno_undefined_callbacks</c></tag>
<item>
<p>Suppress warnings about behaviors that have no
<c>-callback</c> attributes for their callbacks.</p>
</item>
<tag><c>-Wno_unused</c></tag>
<item>
<p>Suppress warnings for unused functions.</p>
</item>
<tag><c>-Wrace_conditions</c> (***)</tag>
<item>
<p>Include warnings for possible race conditions. Notice that the
analysis that finds data races performs intra-procedural data flow
analysis and can sometimes explode in time. Enable it at your own
risk.</p>
</item>
<tag><c>-Wunderspecs</c> (***)</tag>
<item>
<p>Warn about underspecified functions (the specification is strictly
more allowing than the success typing).</p>
</item>
<tag><c>-Wunknown</c> (***)</tag>
<item>
<p>Let warnings about unknown functions and types affect the
exit status of the command-line version. The default is to ignore
warnings about unknown functions and types when setting the exit
status. When using Dialyzer from Erlang, warnings about unknown
functions and types are returned; the default is not to return
these warnings.</p>
</item>
<tag><c>-Wunmatched_returns</c> (***)</tag>
<item>
<p>Include warnings for function calls that ignore a structured return
value or do not match against one of many possible return
value(s).</p>
</item>
</taglist>
<p>The following options are also available, but their use is not
recommended (they are mostly for Dialyzer developers and internal
debugging):</p>
<taglist>
<tag><c>-Woverspecs</c> (***)</tag>
<item>
<p>Warn about overspecified functions (the specification is strictly
less allowing than the success typing).</p>
</item>
<tag><c>-Wspecdiffs</c> (***)</tag>
<item>
<p>Warn when the specification is different than the success typing.</p>
</item>
</taglist>
<note>
<p>*** denotes options that turn on warnings rather than
turning them off.</p>
</note>
</section>
<section>
<title>Using Dialyzer from Erlang</title>
<p>Dialyzer can be used directly from Erlang. Both the GUI and the
command-line versions are also available. The options are similar to the
ones given from the command line, see section
<seealso marker="#command_line">
Using Dialyzer from the Command Line</seealso>.</p>
</section>
<section>
<marker id="suppression"></marker>
<title>Requesting or Suppressing Warnings in Source Files</title>
<p>Attribute <c>-dialyzer()</c> can be used for turning off
warnings in a module by specifying functions or warning options.
For example, to turn off all warnings for the function
<c>f/0</c>, include the following line:</p>
<code type="none">
-dialyzer({nowarn_function, f/0}).</code>
<p>To turn off warnings for improper lists, add the following line
to the source file:</p>
<code type="none">
-dialyzer(no_improper_lists).</code>
<p>Attribute <c>-dialyzer()</c> is allowed after function
declarations. Lists of warning options or functions are allowed:</p>
<code type="none">
-dialyzer([{nowarn_function, [f/0]}, no_improper_lists]).</code>
<p>Warning options can be restricted to functions:</p>
<code type="none">
-dialyzer({no_improper_lists, g/0}).</code>
<code type="none">
-dialyzer({[no_return, no_match], [g/0, h/0]}).</code>
<p>For help on the warning options, use <c>dialyzer -Whelp</c>. The
options are also enumerated, see function <seealso marker="#gui/1">
<c>gui/1</c></seealso> below (<c>WarnOpts</c>).</p>
<note>
<p>Warning option <c>-Wrace_conditions</c> has no effect when
set in source files.</p>
</note>
<p>Attribute <c>-dialyzer()</c> can also be used for turning on
warnings. For example, if a module has been fixed regarding
unmatched returns, adding the following line can help in assuring
that no new unmatched return warnings are introduced:</p>
<code type="none">
-dialyzer(unmatched_returns).</code>
</section>
<funcs>
<func>
<name>format_warning(Msg) -> string()</name>
<fsummary>Get the string version of a warning message.</fsummary>
<type>
<v>Msg = {Tag, Id, msg()}</v>
<d>See <c>run/1</c>.</d>
</type>
<desc>
<p>Get a string from warnings as returned by
<seealso marker="#run/1"><c>run/1</c></seealso>.</p>
</desc>
</func>
<func>
<name>gui() -> ok | {error, Msg}</name>
<name>gui(OptList) -> ok | {error, Msg}</name>
<fsummary>Dialyzer GUI version.</fsummary>
<type>
<v>OptList</v>
<d>See below.</d>
</type>
<desc>
<p>Dialyzer GUI version.</p>
<code type="none">
OptList :: [Option]
Option :: {files, [Filename :: string()]}
| {files_rec, [DirName :: string()]}
| {defines, [{Macro :: atom(), Value :: term()}]}
| {from, src_code | byte_code}
%% Defaults to byte_code
| {init_plt, FileName :: string()}
%% If changed from default
| {plts, [FileName :: string()]}
%% If changed from default
| {include_dirs, [DirName :: string()]}
| {output_file, FileName :: string()}
| {output_plt, FileName :: string()}
| {check_plt, boolean()},
| {analysis_type, 'succ_typings' |
'plt_add' |
'plt_build' |
'plt_check' |
'plt_remove'}
| {warnings, [WarnOpts]}
| {get_warnings, bool()}
WarnOpts :: error_handling
| no_behaviours
| no_contracts
| no_fail_call
| no_fun_app
| no_improper_lists
| no_match
| no_missing_calls
| no_opaque
| no_return
| no_undefined_callbacks
| no_unused
| race_conditions
| underspecs
| unknown
| unmatched_returns
| overspecs
| specdiffs</code>
</desc>
</func>
<func>
<name>plt_info(string()) -> {'ok', [{atom(), any()}]} | {'error', atom()}</name>
<fsummary>Return information about the specified PLT.</fsummary>
<desc>
<p>Returns information about the specified PLT.</p>
</desc>
</func>
<func>
<name>run(OptList) -> Warnings</name>
<fsummary>Dialyzer command-line version.</fsummary>
<type>
<v>OptList</v>
<d>See <c>gui/0,1</c>.</d>
<v>Warnings</v>
<d>See below.</d>
</type>
<desc>
<p>Dialyzer command-line version.</p>
<code type="none">
Warnings :: [{Tag, Id, Msg}]
Tag :: 'warn_behaviour'
| 'warn_bin_construction'
| 'warn_callgraph'
| 'warn_contract_not_equal'
| 'warn_contract_range'
| 'warn_contract_subtype'
| 'warn_contract_supertype'
| 'warn_contract_syntax'
| 'warn_contract_types'
| 'warn_failing_call'
| 'warn_fun_app'
| 'warn_matching'
| 'warn_non_proper_list'
| 'warn_not_called'
| 'warn_opaque'
| 'warn_race_condition'
| 'warn_return_no_exit'
| 'warn_return_only_exit'
| 'warn_umatched_return'
| 'warn_undefined_callbacks'
| 'warn_unknown'
Id = {File :: string(), Line :: integer()}
Msg = msg() -- Undefined</code>
</desc>
</func>
</funcs>
</erlref>
|