Tweak the alarms documentation
Diffstat (limited to 'doc')
-rw-r--r--doc/src/guide/listeners.asciidoc10
-rw-r--r--doc/src/manual/ranch.asciidoc8
2 files changed, 9 insertions, 9 deletions
diff --git a/doc/src/guide/listeners.asciidoc b/doc/src/guide/listeners.asciidoc
index 65ade28..9ee2d98 100644
--- a/doc/src/guide/listeners.asciidoc
+++ b/doc/src/guide/listeners.asciidoc
@@ -331,8 +331,8 @@ processes.
=== Setting connection count alarms
The `alarms` transport option allows you to configure alarms
-which will be triggered when the number of connections under a connection
-supervisor reaches or exceeds the defined treshold.
+which will be triggered when the number of connections tracked
+by one connection supervisor reaches or exceeds the defined treshold.
The `alarms` transport option takes a map with alarm names as keys and alarm
options as values.
@@ -343,7 +343,7 @@ Alarm options include the alarm type and a treshold that, when reached,
triggers the given callback. A cooldown prevents the alarm from being
triggered too often.
-.Setting an alarm to log warnings when the number of connections exceed 100
+.Log warnings when the number of connections exceeds 100
[source,erlang]
----
@@ -366,8 +366,8 @@ Alarms = #{
----
In the example code, an alarm named `my_alarm` is defined, which will
-call the given function when the number of connections under a
-connection supervisor reaches or exceeds 100. When the number of
+call the given function when the number of connections tracked
+by the connection supervisor reaches or exceeds 100. When the number of
connections is still (or again) above 100 after the default cooldown
period of 5 seconds, the alarm will trigger again.
diff --git a/doc/src/manual/ranch.asciidoc b/doc/src/manual/ranch.asciidoc
index af006a2..14add7d 100644
--- a/doc/src/manual/ranch.asciidoc
+++ b/doc/src/manual/ranch.asciidoc
@@ -117,8 +117,8 @@ None of the options are required.
alarms (#{})::
-Alarms to call a function when the number of connections under a
-connection supervisor reaches or exceeds a defined treshold.
+Alarms to call a function when the number of connections tracked
+by one connection supervisor reaches or exceeds a defined treshold.
+
The map keys are the alarm names, which can be any `term`. The
associated values are the respective alarm options, again in a map
@@ -131,8 +131,8 @@ Must be set to `num_connections`.
treshold:::
Treshold value, which must be a `non_neg_integer`. When the
-number of connections under a connection supervisor reaches
-or exceeds this value, The alarm will trigger and call
+number of connections tracked by a single connection supervisor
+reaches or exceeds this value, The alarm will trigger and call
the function defined in the `callback` key (see below).
callback:::